Broadband photodetectors play a significant role in quantum optics and quantum information processing including the detection of squeezed pulses, quantum state reconstruction, and continuous-variable quantum key distribution system. By the noise analysis model of the photodetector based on transimpedance amplifier circuit, the electronic noise and signal noise characteristics are theoretically analyzed. And based on the PSpice simulation model, the effects of themain parameters on the performance of the photodetector are analyzed in detail. The input voltage noise of the operational amplifier is the main noise source of electronic noise, and the current noise of the operational amplifier affects the magnitude ofthe low-frequency noise. The input parasite capacitances play a non-negligible influence on the noise power spectrum. With the increase of the input parasitic capacitance, the electronic noise increases and the signal-to-noise ratio decreases. Through the comparisons between the theoretical calculation and the simulation results, these two analysis methods are equivalent. A wideband photodetector is developed by using a low-noise operational amplifier of OPA847. The experimental noise power spectrum is in good agreement with the simulation results, and the -3 dB bandwidth of the photodetector is 110 MHz.
Broadband photodetectors play a significant role in quantum optics and quantum information processing including the detection of squeezed pulses, quantum state reconstruction, and continuous-variable quantum key distribution system. By the noise analysis model of the photodetector based on transimpedance amplifier circuit, the electronic noise and signal noise characteristics are theoretically analyzed. And based on the PSpice simulation model, the effects of themain parameters on the performance of the photodetector are analyzed in detail. The input voltage noise of the operational amplifier is the main noise source of electronic noise, and the current noise of the operational amplifier affects the magnitude ofthe low-frequency noise. The input parasite capacitances play a non-negligible influence on the noise power spectrum. With the increase of the input parasitic capacitance, the electronic noise increases and the signal-to-noise ratio decreases. Through the comparisons between the theoretical calculation and the simulation results, these two analysis methods are equivalent. A wideband photodetector is developed by using a low-noise operational amplifier of OPA847. The experimental noise power spectrum is in good agreement with the simulation results, and the -3 dB bandwidth of the photodetector is 110 MHz.
A low-noise photodetector is a basic tool for the research of quantum information processing.We present a specially designed low-noise photoelectric detector with a bandwidth of 130 MHz, using a transimpedance amplification circuit.Based on the detailed calculation of the dependence on each parameter of the detector, a useful method of how to design a low-noise and broadband photodetector is provided.When the optical power is between 1.0 and 16 mW, the photodetector has a good linear response to the injected light.Its electronics noise power is below -77 dBm, which is within the whole bandwidth.When the incident light power is 2 mW, the output noise powers are 10.0, 8.0, and 6.0 dB higher than the corresponding electronics noise within the bandwidth of 1-50, 50-90, and 90-130 MHz, respectively, which is in good agreement with the theoretical prediction.Thus, this photoelectric detector could have good application prospects in quantum communication and an optical cavity locking system.
Objective The balanced homodyne detector (BHD) is widely used in quantum noise measurement, gravitational wave detection, high-sensitivity interferometric timing measurement, continuous-variable quantum key distribution, and quantum random number generation. Highly sensitive to the amplitude and phase of the incident light, the BHD can reliably extract quantum fluctuations, suppress the classical common-mode noise, and amplify quantum fluctuations to the macro level. However, the performance of the BHD is limited by the bandwidth, signal-to-noise ratio (SNR), and common-mode rejection ratio (CMRR) of the detector. The optimal design of the BHD has always been a research hotspot. The transimpedance circuit based on a direct current (DC) coupled circuit is not suitable for detecting quantum noise. The reason is that as the power of the incident light increases, the unbalanced DC increases rapidly, and the transimpedance amplifier is saturated, which significantly reduces the dynamic range of the BHD. The BHD based on an inductor-capacitor (L-C) coupled circuit generates higher electronic noise at an analyzing frequency in the kHz range. It is not suitable for low-frequency measurements due to the parasitic effect of the inductor and the low impedance of the inductor at an analyzing frequency in the kHz range. In this paper, the noise sources of the BHD are analyzed theoretically, and a resistor-capacitor (R-C) coupled transimpedance circuit is used to improve the performance of the BHD at an analyzing frequency in the kHz range. Furthermore, the transimpedance circuit is optimized to increase the bandwidth to 200 MHz. The CMRR of the BHD is improved by designing a self-subtraction photodetector scheme, a variable optical attenuator, and an adjustable reverse bias voltage. These designs allow the BHD to meet the low-frequency and high-frequency measurements with high SNR and CMRR in quantum noise measurement. Methods To enable the BHD to measure both low-frequency and high-frequency signals with high sensitivity, this paper adopts the BHD based on an R-C coupled transimpedance circuit. Two photodiodes are connected in series, and the balanced current signal in the two photodiodes is divided into a DC signal and an alternating current (AC) signal by the R-C coupled structure. The AC signal is converted into a voltage signal by a transimpedance amplifier (TIA) and is further used to measure the shot-noise power of the incident light. The DC signal is converted into a voltage signal by a load resistor and is then used to measure the balance between the two incident lights. To reduce the crosstalk between the DC circuit and the AC circuit, an isolation amplifier is added after the load resistor. An adjustable bias voltage (BV) circuit is used to adjust the junction capacitance of the photodiodes and further improve the CMRR. To compensate for the difference in the amplitude of the two photodiodes and thereby improve the CMRR of the BHD, the paper also utilizes a variable optical attenuator based on fiber bending, where variable attenuation is achieved by changing the radius of the bent fiber. The attenuation of the fiber is precisely adjusted to balance the photocurrent. In addition, an equivalent noise model is constructed. The electronic noise from the TIA circuit includes four parts, i.e., the noise introduced by the dark current in the photodiodes, the thermal noise in the feedback resistor, the noise generated by the input current noise in the TIA, and the noise produced by the input voltage noise. On the basis of theoretical analysis, reasonable DC load resistance and feedback capacitance, photodiodes with low dark current and low junction capacitance, and a TIA with low input noise are selected to reduce the electronic noise and improve the SNR of the BHD. Results and Discussions A BHD with an R-C coupled circuit structure is designed (Fig. 1). A test device is built to test the performance of the BHD. The AC output is connected with a spectrometer to measure the bandwidth and the SNR of the BHD. The DC output is connected with an oscilloscope to make sure that the power of the two incident lights is balanced (Fig. 3). When the incident optical power is 8, 4, 2, and 1 mW, respectively, the paper tests the shot-noise spectrum and the electronic noise spectrum of the BHD with different analyzing frequencies. The test results show that the 3-dB bandwidth of the BHD is 1 kHz-200 MHz. The resolution bandwidth (RBW) and the video bandwidth (VBW) of the spectrum analyzer are set to 10 Hz and 1 Hz, respectively, and the number of averaging times is set to 40. In this case, the SNR is 12 dB at the analyzing frequency of 5 kHz under an incident optical power of 8 mW. The SNR is 20 dB at the analyzing frequency of 100 MHz when the RBW is 200 kHz and the VBW is 100 Hz. Moreover, in the analyzing frequency range of 10 kHz-200 MHz, the shot-noise power decreases by about 3 dB when the incident optical power decreases by half, indicating that the AC output of the BHD has favorable linear gain characteristics in the range of 1 mW to 8 mW (Fig. 4). In addition, 5 kHz and 100 MHz sinusoidal signals are loaded into an electro-optical amplitude modulator to modulate the incident light and thereby test the CMRR. The results show that the CMRR is 70 dB at the analyzing frequency of 5 kHz and 66 dB at the analyzing frequency of 100 MHz (Fig. 5). Conclusions By analyzing the noise sources of the BHD, adopting the R-C coupled transimpedance circuit, and optimizing the TIA circuit, this paper implements a broadband balanced homodyne detector that works in the bandwidth range from 1 kHz to 200 MHz with low noise and high CMRR. In the case of an incident optical power of 8 mW@1550 nm, the shot-noise power is 12 dB higher than the electronic noise power and the CMRR reaches 70 dB at the analyzing frequency of 5 kHz, and the shot-noise power is 20 dB higher than the electronic noise power and the CMRR reaches 66 dB at the analyzing frequency of 100 MHz. Such a homodyne detector can serve as a high-performance detection tool in various applications, such as low-frequency gravitational wave detection, high-speed continuous-variable quantum key distribution, and high-speed quantum random number generation.
In this paper, two models for simulating the shot noise and electronic noise performances of resonant photodetectors designed for homodyne measurements are presented. One is based on a combination of a buffer and a low-noise amplifier, and the other is based on an operational amplifier. Through the comparisons between the numerical simulation results and the experimentally obtained data, excellent agreements are achieved, which show that the models provide a highly efficient guide for the development of a high signal-to-noise ratio (SNR) resonant photodetector. Furthermore, we demonstrate a high SNR resonant photodetector for homodyne measurements at the 147 MHz optical sideband, achieving a 20.8 dB SNR of the shot noise to the electronic noise with a 2 mW optical signal input, utilizing a combination of a buffer and a low-noise amplifier. Concurrently, we have obtained another resonant photodetector at the 1.14 GHz optical sideband, which exhibits a 13 dB SNR based on an operational amplifier.
Objective In squeezing-enhanced system, the stability and squeezing level of the squeezed states directly affect the improvement of quantum enhancement sensitivity and signal-to-noise ratio (SNR). Squeezed states can be generated by an optical parametric oscillator (OPO) based on second-order nonlinearity. At present, Pound-Drever-Hall (PDH) is the most commonly employed method for locking the OPO cavity, and the photodetector plays a key role in extracting extremely weak signals. For PDH locking systems, the useful signals coupled to photodetectors are narrowband signals at the modulated frequency, while the traditional wideband photodetectors amplify signals and noise in the whole frequency band, which is not conducive to improving the SNR. It is worth noting that the seed light is employed in the active stable parametric cavity in the preparation of the bright squeezed state, and the increased seed power will lead to the coupling of the pump noise into the bright squeezed state, thereby resulting in the reduced squeezing level. However, the increased optical power of extracting signal can improve the error signal of the locked parameter cavity. Thus, it is important to design photodetectors with high gain and SNR. Photodiodes have certain junction capacitance, and combined with variable inductance, inductance and capacitance (LC) resonance circuit can be formed to enhance the resonance of specific frequency signals. The detector is named resonant photodetector (RPD). The LC resonance circuit can be equivalent to the parallel resonance circuit and is regarded as a bandpass filter, which only amplifies the required frequency band and suppresses the noise of unnecessary frequency bands. However, the quality factor Q directly characterizes the suppression effect on the external noise signal of the resonant frequency, and the SNR of the error signal directly affects the minimum jitter of the cavity length and phase after locking. Methods To evaluate the newly designed RPD, this paper builds a test platform to evaluate transfer functions and error signals, as shown in Fig. 4. The laser source is a single-frequency laser of 1550 nm. The half-wave plate HWP1 is employed to adjust the laser power reaching the modulator, and HWP2 is to adjust the polarization direction of the laser, perpendicular or horizontal to the modulator. This means that the direction is 45°from the main axis of the electro-optical crystal. The network analyzer sets the start and end frequencies of the test (starting from 1-100 MHz in the experiment, and then being refined according to the resonance frequency). The output signal is divided into two parts, one of which is loaded on the modulator for modulating the laser beam, and the other is returned as a reference signal. The second part is the measurement of the error signal, which adopts the electro-optical modulator (EOM). MC is closely related to the preparation of high level squeezed state. According to PDH technology, the anti-interference ability of locking is proportional to the peak-to-peak value of the error signal, and the larger peak-to-peak value will lead to stronger anti-interference ability. In addition to the incident laser power, the amplitude and SNR of the error signal also depend on the signal extraction capability of the photodetector, so the SNR of the error signal extracted by the photodetector determines the stability of the whole feedback loop. Therefore, the performance of the developed resonant detector is evaluated by the SNR and the stability of the error signal in MC cavity locking. Results and Discussions This paper measures the transfer functions of commercial BPD (THORLABS PDA10D2) and RPD under the same conditions (Fig. 5). At the resonant frequency of 20 MHz, the gain of RPD is about 30 dB higher than that of BPD. The high gain helps to obtain a stable phase locking at lower power, thus improving the stability of the system in the squeezed state without reducing the quantum noise. Through external mixing and integrated circuit design, the 3 dB bandwidth of RPD is 0.285 MHz. The quality factor Q of RPD is 70 and can be calculated from the measurement results by Formula (5). The experimental results are shown in Figs. 6 and 7. The SNR improvement of the newly designed RPD is more obvious than that of BPD, and the SNR is defined as the ratio of the peak-to-peak value to the noise of the error signal. The error signal is a DC signal, which cannot be measured by a spectrum analyzer and can only be recorded by an oscilloscope. At the resonance frequency of 20 MHz, the peak-to-peak value of the RPD error signal is 560 mV, the peak-to-peak value of noise is 42 mV, and the SNR is about 22.5 dB. The peak-to-peak value of the BPD error signal is 35 mV, and the peak-to-peak value of noise is 20.8 mV. The SNR of the newly designed RPD is about 18 dB higher than that of BPD. Conclusions Based on the theoretical analysis of the resonance circuit and cross-resistance amplifier circuit, the selection of low noise devices, and the optimized circuit layout, this paper develops a resonant detector with Q factor of 70 and SNR of 22.5 dB. Compared with the traditional broadband photodetector (BPD), the gain of RPD at 20 MHz is about 30 dB higher than that of BPD. By measuring the peak-to-peak value and SNR of error signals, the peak-to-peak value of RPD locking cavity error signals is 16 times that of BPD, and the SNR of RPD error signals is about 18 dB higher than that of BPD under the same condition. This RPD can provide a key device for photoelectric feedback control and the preparation of continuous variable nonclassical light fields.
High-precision cavity locking is crucial for squeezing optical fields. Here, a bootstrapped low-noise photodetector is utilized in the generation process of the squeezed state of light. This process is based on a combination of a modified trans-impedance amplifier (TIA) circuit and a two-stage bootstrap amplifier circuit. This not only achieves high-precision and long-term stable locking of the optical cavity, but it also improves the degree to which the light field is squeezed. The experiment results show that the detector has a high signal-to-noise ratio (SNR) of 26.7 dB at the analysis frequency of 3 MHz when measuring the shot noise with an injection optical power of 800 µW, and the equivalent optical power noise level is lower than 2.4 pW/Hz in the frequency range of 1-30 MHz. Moreover, the squeezing degree of the quadrature amplitude squeezed state light field can be improved by more than 34.9% when the detector is used for optical cavity locking. The photodetector is useful in continuous variable (CV) quantum information research.
We design and demonstrate a resonant-type differential photodetector for a low-noise quantum homodyne measurement at 500 MHz optical sideband with 17 MHz of bandwidth. By using a microwave monolithic amplifier and a discrete voltage buffer circuit, a low-noise voltage amplifier is realized and applied to our detector. 12 dB of signal-to-noise ratio of the shot noise to the electric noise is obtained with 5 mW of a continuous-wave local oscillator. We analyze the frequency response and the noise characteristics of a resonant photodetector, and the theoretical model agrees with the shot noise measurement.