Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Cooling and Crystallization of Trapped Single 171Yb+ Ion for Optical Frequency Standard

Jize Han, Y. H. Zheng, S. N. Miao, Yiting Chen, Jianwei Zhang, Lijun Wang, Lei Han, Xing Chen, Xiaobo Xue, Shengkang Zhang

Published May 15, 2023• 0 citations
Publisher

Abstract

By measuring the frequencies emitted as atoms transition between energy levels, atomic frequency standards are among the most advanced devices available for keeping time. Here, we report our recent progress in developing an optical frequency standard based on a single171Yb+. With the laser Doppler cooling, a single ytterbium ion is cooled to crystallization and the temperature of the ion crystal is estimated to be below 1 mK. The progress reported in this paper is the first step of the project and paves the way for future development.

DOI
10.1109/eftf/ifcs57587.2023.10272099

Related papers

Single Trapped 171Yb+ for Optical Frequency Standards

Atish Roy, Lakhi Sharma, Harish Kumar Rathore +5 more

An optical clock or frequency standard based on the interrogation of an atomic transition in the optical domain, operates at ~1014Hz is capable of providing orders of magnitude better accuracy than the present primary standard of frequency or time operating in the microwave range. Optical transitions of an ions, confined within a radio frequency ion trap and laser cooled to ~mK temperature, provides better long term stability since they are free from Coulomb and intra-atomic interactions. Optical frequency standards have been realized with several ions, e.g.,199Hg+,171Yb+,115In+,88Sr+,40Ca+,27Al+and among those171Y+has multiple ultra-narrow optical transitions suitable for serving as frequency standards [1-2].

URSI Asia-Pacific Radio Science Conference•Mar 1, 2019•0 citations

Cooling and Crystallization of Trapped 113 Cd + Ions for Atomic Clock

Shiguang Wang, Jianwei Zhang, K. Miao +2 more

We report recent experimental progress toward a trapped 113Cd+ ion microwave frequency standard. With laser cooling, a large number of trapped cadmium ions are cooled to crystallization and the temperature of the ion crystal is measured to be 16±3 mK. The second order Doppler frequency shift, a main limiting factor of the atomic clock's performance, is estimated to be less than 1 × 10−16.

Chinese Physics Letters•Jan 1, 2013•8 citations

Optical frequency standards and clocks based on single trapped ions

Helen S. Margolis, G. P. Barwood, Kazumoto Hosaka +6 more

Forbidden transitions in single laser-cooled trapped ions provide highly stable and accurate references for optical frequency standards. This paper describes recent progress on strontium and ytterbium ion optical frequency standards under development at NPL.

Conference on Lasers and Electro-Optics•Jan 1, 2006•0 citations

Trapped ion optical frequency standards

Patrick Robert Gill, G. P. Barwood, Hugh A. Klein +6 more

Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.

Measurement Science and Technology•Jul 16, 2003•44 citations

Laser system for Doppler cooling of ytterbium ion in an optical frequency standard

S. V. Chepurov, A.A. Lugovoy, S N Kuznetsov

A laser system for Doppler cooling of ytterbium ion on the transition in a single-ion optical frequency standard is developed. The second harmonic of a semiconductor laser with a wavelength of is used for cooling. The laser frequency is doubled in a nonlinear BiBO crystal embedded in a ring resonator, which also serves as a reference for laser frequency stabilisation. Second-harmonic power of is generated at a wavelength of . Diode laser radiation is modulated by an electro-optic modulator at to generate a sideband exciting the hyperfine component of the cooling transition that is not excited by resonant cooling light. The sideband relative intensity of a few percent proved to be sufficient to reduce the ion dwelling time in the state to less than and increase the cooling efficiency.

Quantum Electronics•Jun 30, 2014•3 citations

Progress Toward an Optical Frequency Standard Based on a Single Indium Ion

Y. H. Wang, T. Liu, Alois Stejskal +7 more

We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•6 citations
By measuring the frequencies emitted as atoms transition between energy levels, atomic frequency standards are among the most advanced devices available for keeping time. Here, we report our recent progress in developing an optical frequency standard based on a single171Yb+. With the laser Doppler cooling, a single ytterbium ion is cooled to crystallization and the temperature of the ion crystal is estimated to be below 1 mK. The progress reported in this paper is the first step of the project and paves the way for future development.
An optical clock or frequency standard based on the interrogation of an atomic transition in the optical domain, operates at ~1014Hz is capable of providing orders of magnitude better accuracy than the present primary standard of frequency or time operating in the microwave range. Optical transitions of an ions, confined within a radio frequency ion trap and laser cooled to ~mK temperature, provides better long term stability since they are free from Coulomb and intra-atomic interactions. Optical frequency standards have been realized with several ions, e.g.,199Hg+,171Yb+,115In+,88Sr+,40Ca+,27Al+and among those171Y+has multiple ultra-narrow optical transitions suitable for serving as frequency standards [1-2].
Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.
A laser system for Doppler cooling of ytterbium ion on the transition in a single-ion optical frequency standard is developed. The second harmonic of a semiconductor laser with a wavelength of is used for cooling. The laser frequency is doubled in a nonlinear BiBO crystal embedded in a ring resonator, which also serves as a reference for laser frequency stabilisation. Second-harmonic power of is generated at a wavelength of . Diode laser radiation is modulated by an electro-optic modulator at to generate a sideband exciting the hyperfine component of the cooling transition that is not excited by resonant cooling light. The sideband relative intensity of a few percent proved to be sufficient to reduce the ion dwelling time in the state to less than and increase the cooling efficiency.
We report on the current status of the optical frequency standard based on a single 115In+ ion. A single Indium ion is being trapped in a Paul-Strauble type trap and cooled in combination of Doppler cooling and sideband cooling to its lowest vibrational states. To interrogate the1S0-3P0clock transition with high accuracy we demonstrate a Hz-level laser system resonant to this transition. With the current setup we are able to achieve a measured linewidth of the clock transition of 260 Hz. The statistical uncertainty of the absolute frequency measurement is 3×10-13, limited mainly by our reference frequency standard.