Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

URSI Asia-Pacific Radio Science Conference

Single Trapped 171Yb+ for Optical Frequency Standards

Atish Roy, Lakhi Sharma, Harish Kumar Rathore, J Saroha, Neelam Neelam, Kavita Kumari, S. De, Subhasis Panja

Published Mar 1, 2019• 0 citations
Publisher

Abstract

An optical clock or frequency standard based on the interrogation of an atomic transition in the optical domain, operates at ~1014Hz is capable of providing orders of magnitude better accuracy than the present primary standard of frequency or time operating in the microwave range. Optical transitions of an ions, confined within a radio frequency ion trap and laser cooled to ~mK temperature, provides better long term stability since they are free from Coulomb and intra-atomic interactions. Optical frequency standards have been realized with several ions, e.g.,199Hg+,171Yb+,115In+,88Sr+,40Ca+,27Al+and among those171Y+has multiple ultra-narrow optical transitions suitable for serving as frequency standards [1-2].

DOI
10.23919/ursiap-rasc.2019.8738233

Related papers

Trapped ion optical frequency standards

Patrick Robert Gill, G. P. Barwood, Hugh A. Klein +6 more

Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.

Measurement Science and Technology•Jul 16, 2003•44 citations

Frequency metrology and clocks

Helen S. Margolis

Transitions between discrete energy levels in well-isolated atomic systems are highly reproducible and therefore make ideal references for highly accurate frequency standards or clocks. In particular, a single laser-cooled ion confined in a radiofrequency ion trap closely approximates the spectroscopic ideal of a particle at rest in a perturbation-free environment. Narrow optical transitions in such systems are therefore very promising for the realization of optical clocks with accuracy around 2 orders of magnitude higher than current microwave primary standards. In this paper the fundamental aspects, current performance and applications of trapped ion optical clocks are reviewed and the potential for future improvements is considered.

Journal of Physics B Atomic Molecular and Optical Physics•Jul 16, 2009•52 citations

Towards an indium single-ion optical frequency standard

Thomas Matthias Becker, M. Eichenseer, Alexander Yu. Nevsky +5 more

Summary form only given. A single laser-cooled ion in a radio frequency trap represents a good approximation to the spectroscopic ideal of an atom in a perturbation-free environment. A narrow transition in such an ion can serve as a reference for a frequency standard of very high accuracy and stability.

Quantum Electronics and Laser Science Conference•Nov 13, 2002•0 citations

An Optical Clock Based on a Single Trapped 199 Hg + Ion

Scott A. Diddams, Thomas Udem, Jonas Bergquist +8 more

Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.

Science•Aug 3, 2001•720 citations

High-accuracy frequency standards using laser-cooled Hg+ ions

Dana J. Berkeland, J.D. Miller, Brent C. Young +3 more

We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 15, 1998•1 citation

Single Indium Ion optical frequency Standard

M. Eichenseer, Alexander Yu. Nevsky, Maksim V. Okhapkin +3 more

A single indium ion stored in a radio frequency trap and laser-cooled to a temperature below 1 mK can serve as an optical frequency standard of exceptionally high accuracy and stability

Conference on Precision Electromagnetic Measurements•Jun 1, 2004•0 citations
An optical clock or frequency standard based on the interrogation of an atomic transition in the optical domain, operates at ~1014Hz is capable of providing orders of magnitude better accuracy than the present primary standard of frequency or time operating in the microwave range. Optical transitions of an ions, confined within a radio frequency ion trap and laser cooled to ~mK temperature, provides better long term stability since they are free from Coulomb and intra-atomic interactions. Optical frequency standards have been realized with several ions, e.g.,199Hg+,171Yb+,115In+,88Sr+,40Ca+,27Al+and among those171Y+has multiple ultra-narrow optical transitions suitable for serving as frequency standards [1-2].
Optical frequency standards based on narrow absorptions in laser-cooled single trapped ions have recently begun to demonstrate stabilities that are competitive with cold atom fountain microwave standards. This paper presents a short review of the wider state-of-the-art development of these single cold trapped ion frequency standards, coupled with a more detailed account of recent results achieved at National Physical Laboratory in respect of single ion systems based on 88Sr+, 87Sr+ and 171Yb+. Narrow linewidth data for the optical clock quadrupole and octupole transitions respectively at 674 nm in 88Sr+ and 467 nm in 171Yb+, are presented, together with a discussion of current systematics and future projections. The potential for optical clock operation is outlined.
Transitions between discrete energy levels in well-isolated atomic systems are highly reproducible and therefore make ideal references for highly accurate frequency standards or clocks. In particular, a single laser-cooled ion confined in a radiofrequency ion trap closely approximates the spectroscopic ideal of a particle at rest in a perturbation-free environment. Narrow optical transitions in such systems are therefore very promising for the realization of optical clocks with accuracy around 2 orders of magnitude higher than current microwave primary standards. In this paper the fundamental aspects, current performance and applications of trapped ion optical clocks are reviewed and the potential for future improvements is considered.
Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.
We discuss frequency standards based on laser-cooled 199Hg+ ions confined in cryogenic rf traps. In one experiment, the frequency of a microwave source is served to the ions' ground-state hyperfine transition at 40.5 GHz. For seven ions and a Ramsey free precession time of 100 s, the fractional frequency stability is 3.3 (2) X 10-13 (tau) -1/2 for measurement times (tau) < 2 h. The ground-state hyperfine interval is measured to be 40 507 347 996.841 59 (14) (41) Hz, where the first number in parentheses is the uncertainty due to statistics and systematic errors, and the second is the uncertainty in the frequency of the time scale to which the standard is compared. In a second experiment under development, a strong-binding cryogenic trap will confine a single ion used for an optical frequency standard based on a narrow electric quadrupole transition at 282 nm. The bandwidth of the laser used to drive this transition is less than 10 Hz at 563 nm.