Chinese Physics Letters

Cooling and Crystallization of Trapped 113 Cd + Ions for Atomic Clock

Shiguang Wang, Jianwei Zhang, K. Miao, Zhengbo Wang, Lijun Wang

Published Jan 1, 2013• 8 citations
Publisher

Abstract

We report recent experimental progress toward a trapped 113Cd+ ion microwave frequency standard. With laser cooling, a large number of trapped cadmium ions are cooled to crystallization and the temperature of the ion crystal is measured to be 16±3 mK. The second order Doppler frequency shift, a main limiting factor of the atomic clock's performance, is estimated to be less than 1 × 10−16.

DOI
10.1088/0256-307x/30/1/013703

Related papers

Direct temperature determination of a sympathetically cooled large 113Cd+ ion crystal for a microwave clock

Y. N. Zuo, J. Z. Han, J. W. Zhang +1 more

This paper reports direct temperature determination of sympathetically cooled 113Cd+ ions with laser-cooled 24Mg+ in a linear Paul trap. The sympathetically cooled ion species distribute in the outer shell of the large ensembles, which contain up to 3.3 × 105 ions. With optimized parameters, the minimum temperature of the sympathetically cooled 113Cd+ ions was measured to be on the order of 10 mK. These results are promising for the performance of microwave atomic clocks. The second-order Doppler frequency shift is two orders of magnitude lower (from 1.88 × 10−14 to 6.26 × 10−16) and the Dick effect is suppressed.

arXiv:1902.10907•Applied Physics Letters•Aug 5, 2019•18 citations

Progress towards a microwave frequency standard based on the laser cooled 113Cd+ ions

Jianwei Zhang, Zhengbo Wang, Shiguang Wang +3 more

The progress towards to a microwave frequency standard based on laser-cooled113Cd+ions trapped in a linear quadrupole trap is reported. The experimental apparatus is introduced and the measurement of the clock transition is demonstrated. The estimated performance of the clock is also discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2012•4 citations

Progress on cadmium-ion and ytterbium-ion Microwave Frequency Standards at Tsinghua University

S. N. Miao, Yajing Zheng, Yong Chen +3 more

Abstract As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance 113Cd+ microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of 4.2 × 10 − 13 / τ and a relative frequency uncertainty of 1.8 × 10−14, improving nearly three orders of magnitude compared to the result from JPL. The 0-0 ground-state hyperfine splitting frequency of 113Cd+ was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using 40Ca+ as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to 3.48 × 10 − 13 / τ . Moreover, a microwave frequency standard based on laser-cooled 171Yb+ ions has also been developed in our laboratory since 2021. The short-term frequency instability was measured to be 8.5 × 10 − 13 / τ . The ground-state hyperfine splitting frequency of 171Yb+ was determined to be 12642812118.4674(8) Hz with a fractional frequency uncertainty of 6.33 × 10−14.

Journal of Physics Conference Series•Nov 1, 2024•0 citations

Towards a high-performance microwave frequency standard based on 113Cd+ ions

Jianwei Zhang, K. Miao, Lijun Wang +2 more

Microwave frequency standards based on ions are promising as the next generation atomic clocks. This paper reports the recent progresses of the microwave frequency standard based on laser-cooled113Cd+ions developed at Tsinghua University. Based on the current experimental setup, the ground-state hyperfine splitting of113Cd+is measured with higher precision and a better short-term frequency stability is obtained than before. To improve the performance of the Cd+clock further, a new experimental setup with dual-traps is designed, and bi-ions operation is proposed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•3 citations

Progress Towards a Microwave Frequency Standard Based on Sympathetically-cooled 113Cd+ Ions

S. N. Miao, Jianwei Zhang, N. C. Xin +5 more

A microwave frequency standard based on113Cd+ions at Tsinghua University has been carried out for twelve years. To overcome the limitations of the Dick effect and the second-order Doppler frequency shift (SODFS), we propose to use heavy174Yb+as the coolant ions to sympathetically cool the large113Cd+cloud, which is expected to further improve the performance of the cadmium-ion microwave frequency standard. This paper reports our recent experimental and simulation progress towards the cadmium-ion microwave frequency standard.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 24, 2022•2 citations

174Yb+–113Cd+ sympathetic-cooling bi-species Coulomb crystal applied to microwave frequency standard

Y.Z. Zheng, H. R. Qin, S. N. Miao +5 more

We reported the realization of a 174Yb+–113Cd+ bi-species Coulomb crystal comprising 174Yb+, a heavier ion, as coolant and verified the potential of applying a coolant ion with a greater mass than the clock ion to sympathetically cooled microwave frequency standard. The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The 113Cd+ ions are trapped in the center, which reduces considerably RF heating and excess micro-motion to which the 113Cd+ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to 5×10−16, which represents an order of magnitude improvement over sympathetic cooled 40Ca+–113Cd+ crystal. The second-order Zeeman frequency shift, which contributes the largest term of the systematic frequency shifts to the microwave ion frequency standard, is estimated to be as low as 7.133×10−13 corresponding to the low value of the operating magnetic field. The relevant AC Stark shift uncertainty is estimated to be 4×10−19. These results demonstrate that using a heavier coolant ion is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a 174Yb+–113Cd+ bicrystal.

Applied Physics Letters•Aug 21, 2023•8 citations
We report recent experimental progress toward a trapped 113Cd+ ion microwave frequency standard. With laser cooling, a large number of trapped cadmium ions are cooled to crystallization and the temperature of the ion crystal is measured to be 16±3 mK. The second order Doppler frequency shift, a main limiting factor of the atomic clock's performance, is estimated to be less than 1 × 10−16.
This paper reports direct temperature determination of sympathetically cooled 113Cd+ ions with laser-cooled 24Mg+ in a linear Paul trap. The sympathetically cooled ion species distribute in the outer shell of the large ensembles, which contain up to 3.3 × 105 ions. With optimized parameters, the minimum temperature of the sympathetically cooled 113Cd+ ions was measured to be on the order of 10 mK. These results are promising for the performance of microwave atomic clocks. The second-order Doppler frequency shift is two orders of magnitude lower (from 1.88 × 10−14 to 6.26 × 10−16) and the Dick effect is suppressed.
Abstract As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance 113Cd+ microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of 4.2 × 10 − 13 / τ and a relative frequency uncertainty of 1.8 × 10−14, improving nearly three orders of magnitude compared to the result from JPL. The 0-0 ground-state hyperfine splitting frequency of 113Cd+ was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using 40Ca+ as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to 3.48 × 10 − 13 / τ . Moreover, a microwave frequency standard based on laser-cooled 171Yb+ ions has also been developed in our laboratory since 2021. The short-term frequency instability was measured to be 8.5 × 10 − 13 / τ . The ground-state hyperfine splitting frequency of 171Yb+ was determined to be 12642812118.4674(8) Hz with a fractional frequency uncertainty of 6.33 × 10−14.
Microwave frequency standards based on ions are promising as the next generation atomic clocks. This paper reports the recent progresses of the microwave frequency standard based on laser-cooled113Cd+ions developed at Tsinghua University. Based on the current experimental setup, the ground-state hyperfine splitting of113Cd+is measured with higher precision and a better short-term frequency stability is obtained than before. To improve the performance of the Cd+clock further, a new experimental setup with dual-traps is designed, and bi-ions operation is proposed.
A microwave frequency standard based on113Cd+ions at Tsinghua University has been carried out for twelve years. To overcome the limitations of the Dick effect and the second-order Doppler frequency shift (SODFS), we propose to use heavy174Yb+as the coolant ions to sympathetically cool the large113Cd+cloud, which is expected to further improve the performance of the cadmium-ion microwave frequency standard. This paper reports our recent experimental and simulation progress towards the cadmium-ion microwave frequency standard.
We reported the realization of a 174Yb+–113Cd+ bi-species Coulomb crystal comprising 174Yb+, a heavier ion, as coolant and verified the potential of applying a coolant ion with a greater mass than the clock ion to sympathetically cooled microwave frequency standard. The two species of massive ions stably trapped in a Paul trap make up this large two-component crystal. The 113Cd+ ions are trapped in the center, which reduces considerably RF heating and excess micro-motion to which the 113Cd+ ions are subjected. Under this scheme, the uncertainty due to the second-order Doppler effect is reduced to 5×10−16, which represents an order of magnitude improvement over sympathetic cooled 40Ca+–113Cd+ crystal. The second-order Zeeman frequency shift, which contributes the largest term of the systematic frequency shifts to the microwave ion frequency standard, is estimated to be as low as 7.133×10−13 corresponding to the low value of the operating magnetic field. The relevant AC Stark shift uncertainty is estimated to be 4×10−19. These results demonstrate that using a heavier coolant ion is far superior and confirm the feasibility of a sympathetic-cooled cadmium-ion microwave clock system employing a 174Yb+–113Cd+ bicrystal.