Journal of Experimental and Theoretical Physics Letters

Surface-Electrode Ion Trap Development

Timur Abbasov, Sergei A. Zibrov, I. Sherstov

Published Jul 31, 2023• 6 citations
Publisher

Abstract

We present a segmented linear surface electrode ion trap design that can be used for various applications in optical clocks and quantum computation based on trapped 171Yb+ ions. Our simulations show that calculated trap depth can reach up to several electronvolts and that the pseudopotential minimum of the trap is located above the trap surface at a distance greater than 80 μm. The described pseudopotential simulations and calculations of different trap parameters can be used to design the planar trap with required parameters. This design could be scaled to store a long chain of ions and used for quantum logic applications as well.

DOI
10.1134/s0021364023602063

Related papers

A grooved planar ion trap design for scalable quantum information processing

Wei-Bang Ji, Jinyin Wan, Hua-Dong Cheng +1 more

We describe a new electrode design for a grooved surface-electrode ion trap, which is fabricated in printed-circuit-board technology with segmented electrodes. This design allows a laser beam to get through the central groove to avoid optical access blocking and laser scattering from the ion trap surface. The confining potentials are modeled both analytically and numerically. We optimize the radio frequency (rf) electrodes and dc electrodes to achieve the maximum trap depth for a given ion height above the trap electrodes. We also compare our design with the reality ion chip MI I for practical considerations. Comparison results show that our design is superior to MI I. This ion trap design may form the basis for large scale quantum computers or parallel quadrupole mass spectrometers.

Chinese Physics B•Jun 1, 2012•2 citations

Surface-Electrode Architecture for Ion-Trap Quantum Information Processing

John Chiaverini, R. B. Blakestad, J. Britton +5 more

We investigate a surface-mounted electrode geometry for miniature linear radio frequency Paul ion traps. The electrodes reside in a single plane on a substrate, and the pseudopotential minimum of the trap is located above the substrate at a distance on order of the electrodes' lateral extent or separation. This architecture provides the possibility to apply standard microfabrication principles to the construction of multiplexed ion traps, which may be of particular importance in light of recent proposals for large-scale quantum computation based on individual trapped ions.

arXiv:quant-ph/0501147•Jan 25, 2005•5 citations

Surface-electrode architecture for ion-trap quantum information processing

John Chiaverini, R. B. Blakestad, J. Britton +5 more

We investigate a surface-mounted electrode geometry for miniature linear radio frequency Paul ion traps. The electrodes reside in a single plane on a substrate, and the pseudopotential minimum of the trap is located above the substrate at a distance on the order of the electrodes' lateral extent or separation. This architecture provides the possibility to apply standard microfabrication principles to the construction of multiplexed ion traps, which may be of particular importance in light of recent proposals for large-scale quantum computation based on individual trapped ions.

Quantum Information and Computation•Sep 1, 2005•145 citations

Surface-electrode architecture for ion-trap quantum information processing

John Chiaverini, R. B. Blakestad, J. Britton +5 more

We investigate a surface-mounted electrode geometry for miniature linear radio frequency Paul ion traps. The electrodes reside in a single plane on a substrate, and the pseudopotential minimum of the trap is located above the substrate at a distance on order of the electrodes' lateral extent or separation. This architecture provides the possibility to apply standard microfabrication principles to the construction of multiplexed ion traps, which may be of particular importance in light of recent proposals for large-scale quantum computation based on individual trapped ions.

Quantum Information and Computation•Sep 1, 2005•195 citations

Optimized Surface Ion Trap Design for Tight Confinement and Separation of Ion Chains

Ilya Gerasin, Nikita O. Zhadnov, K. S. Kudeyarov +3 more

Qubit systems based on trapped ultracold ions win one of the leading positions in the quantum computing field, demonstrating quantum algorithms with the highest complexity to date. Surface Paul traps for ion confinement open the opportunity to scale quantum processors to hundreds of qubits and enable high-connectivity manipulations on ions. To fabricate such a system with certain characteristics, the special design of a surface electrode structure is required. The depth of the trapping potential, the stability parameter, the secular frequency and the distance between an ion and the trap surface should be optimized for better performance. Here, we present the optimized design of a relatively simple surface trap that allows several important high-fidelity primitives: tight ion confinement, laser cooling, and wide optical access. The suggested trap design also allows us to perform an important basic operation, namely, splitting an ion chain into two parts.

arXiv:2407.14195•Quantum Reports•Aug 23, 2024•4 citations

Design, fabrication and experimental demonstration of junction surface ion traps

D L Moehring, C Highstrete, Daniel Stick +4 more

We present the design, fabrication and experimental implementation of surface ion traps with Y-shaped junctions. The traps are designed to minimize the pseudopotential variations in the junction region at the symmetric intersection of three linear segments. We experimentally demonstrate robust linear and junction shuttling with greater than 10 6 round-trip shuttles without ion loss. By minimizing the direct line of sight between trapped ions and dielectric surfaces, negligible day-to-day and trap-to-trap variations are observed. In addition to high-fidelity single-ion shuttling, multiple-ion chains survive splitting, ion-position swapping and recombining routines. The development of two-dimensional trapping structures is an important milestone for ion-trap quantum computing and quantum simulations.

arXiv:1105.1834•New Journal of Physics•Jul 29, 2011•93 citations
We present a segmented linear surface electrode ion trap design that can be used for various applications in optical clocks and quantum computation based on trapped 171Yb+ ions. Our simulations show that calculated trap depth can reach up to several electronvolts and that the pseudopotential minimum of the trap is located above the trap surface at a distance greater than 80 μm. The described pseudopotential simulations and calculations of different trap parameters can be used to design the planar trap with required parameters. This design could be scaled to store a long chain of ions and used for quantum logic applications as well.
We describe a new electrode design for a grooved surface-electrode ion trap, which is fabricated in printed-circuit-board technology with segmented electrodes. This design allows a laser beam to get through the central groove to avoid optical access blocking and laser scattering from the ion trap surface. The confining potentials are modeled both analytically and numerically. We optimize the radio frequency (rf) electrodes and dc electrodes to achieve the maximum trap depth for a given ion height above the trap electrodes. We also compare our design with the reality ion chip MI I for practical considerations. Comparison results show that our design is superior to MI I. This ion trap design may form the basis for large scale quantum computers or parallel quadrupole mass spectrometers.
We investigate a surface-mounted electrode geometry for miniature linear radio frequency Paul ion traps. The electrodes reside in a single plane on a substrate, and the pseudopotential minimum of the trap is located above the substrate at a distance on order of the electrodes' lateral extent or separation. This architecture provides the possibility to apply standard microfabrication principles to the construction of multiplexed ion traps, which may be of particular importance in light of recent proposals for large-scale quantum computation based on individual trapped ions.
We investigate a surface-mounted electrode geometry for miniature linear radio frequency Paul ion traps. The electrodes reside in a single plane on a substrate, and the pseudopotential minimum of the trap is located above the substrate at a distance on the order of the electrodes' lateral extent or separation. This architecture provides the possibility to apply standard microfabrication principles to the construction of multiplexed ion traps, which may be of particular importance in light of recent proposals for large-scale quantum computation based on individual trapped ions.
We investigate a surface-mounted electrode geometry for miniature linear radio frequency Paul ion traps. The electrodes reside in a single plane on a substrate, and the pseudopotential minimum of the trap is located above the substrate at a distance on order of the electrodes' lateral extent or separation. This architecture provides the possibility to apply standard microfabrication principles to the construction of multiplexed ion traps, which may be of particular importance in light of recent proposals for large-scale quantum computation based on individual trapped ions.
Qubit systems based on trapped ultracold ions win one of the leading positions in the quantum computing field, demonstrating quantum algorithms with the highest complexity to date. Surface Paul traps for ion confinement open the opportunity to scale quantum processors to hundreds of qubits and enable high-connectivity manipulations on ions. To fabricate such a system with certain characteristics, the special design of a surface electrode structure is required. The depth of the trapping potential, the stability parameter, the secular frequency and the distance between an ion and the trap surface should be optimized for better performance. Here, we present the optimized design of a relatively simple surface trap that allows several important high-fidelity primitives: tight ion confinement, laser cooling, and wide optical access. The suggested trap design also allows us to perform an important basic operation, namely, splitting an ion chain into two parts.
We present the design, fabrication and experimental implementation of surface ion traps with Y-shaped junctions. The traps are designed to minimize the pseudopotential variations in the junction region at the symmetric intersection of three linear segments. We experimentally demonstrate robust linear and junction shuttling with greater than 10 6 round-trip shuttles without ion loss. By minimizing the direct line of sight between trapped ions and dielectric surfaces, negligible day-to-day and trap-to-trap variations are observed. In addition to high-fidelity single-ion shuttling, multiple-ion chains survive splitting, ion-position swapping and recombining routines. The development of two-dimensional trapping structures is an important milestone for ion-trap quantum computing and quantum simulations.