Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

Signal-processing electronics for stable and sensitive weak-field atomic vector magnetometers

Hongwei Zhou, X.-K. Wang, S.-Q. Liu, Liansheng Cheng, Kai Liu, Zonghao Pan, Yiren Li, Xinjun Hao, Dong Sheng, Yuming Wang

Published May 1, 2023• 0 citations
Publisher

Abstract

We present the electronics developed for a sensitive and stable atomic vector magnetometer used in low-field detections. These electronics are required to be not only highly reliable and sophisticated for signal processing but also compact in size and low cost in resource consumption for the purpose of miniaturization. In addition, this magnetometer works with multiple modulations, where the interferences between harmonics of modulation fields often disturb the long-term measurements of the sensor. We work out a robust method to eliminate this problem by choosing the modulation frequencies with separations to match the minimum response points of the low-pass filters used in the demodulation processes. We validate the performance of the electronics and the frequency-selection scheme of the modulation fields with corresponding experimental results.

DOI
10.1063/5.0150256

Related papers

Sensitive and Stable Atomic Vector Magnetometer to Detect Weak Fields Using Two Orthogonal Multipass Cavities

S.-Q. Liu, Q.-Q. Yu, Hongwei Zhou +1 more

This paper presents a compact low-temperature atomic vector magnetometer for weak-field measurements, using an atomic cell containing two orthogonal multipass cavities. At the working temperature of $75{\phantom{\rule{0.1em}{0ex}}}^{\ensuremath{\circ}}\mathrm{C}$, the magnetic field sensitivities at all three axes are better than $45\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$ at 10 Hz limited by photon noise, and $85\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$ at 0.1 Hz. This sensor also shows measurement stabilities better than 1.5 pT at three axes for an integration time of ${10}^{4}\phantom{\rule{0.2em}{0ex}}\mathrm{s}$, even with the laser frequency unlocked. The sensor response to a rotation is demonstrated, which is also developed to measure the effective gyromagnetic ratio of atoms in this sensor when the bias field is nulled. This magnetometer makes an important step towards long-term stable measurements and calibrations of ultralow fields.

arXiv:2303.04354•Physical Review Applied•Apr 21, 2023•15 citations

Vector Atomic Magnetometer with Free Induction Decay Detection Based on a Microfabricated Vapor Cell

Pengbo Jiang, Qi Li, Jianan Qin +1 more

Atomic magnetometers are highly sensitive instruments widely used for measurements of weak magnetic field. Extracting vector information while maintaining high-precision scalar detection has become the trend in atomic magnetometer development. We introduce a vector atomic magnetometer containing a 5 mm-thick microfabricated vapor cell operating in free-induction-decay mode. By employing orthogonal modulation techniques, the system achieves high-precision in-plane vector magnetic field measurements. The high-precision vector magnetic field measurements are demonstrated in the x–z plane. The sensitivity of the total field detection in the miniaturized atomic magnetometer is 30 pT·Hz−1/2 @11 µT. The average angular error of the decoupled measurement is as low as 4.7 mrad @7.6 µT for vector magnetic fields, providing a new approach for vector magnetic field measurement in miniaturized atomic magnetometers.

Micromachines•Dec 30, 2024•2 citations

Miniature Wide-Range Three-Axis Vector Atomic Magnetometer

Jianjun Li, Deng Yicheng, Xuefeng Wang +2 more

A miniature wide-range three-axis vector atomic magnetometer under spin-exchange relaxation-free regime has been developed. With a cylindrical vapor cell of size 10 mm in diameter and length, we have constructed a single-beam configuration through a polarization-maintaining fiber carrying the laser beam to the sensor and a multimode fiber guiding the transmitted light field to the photodiode. A rotating field on the plane perpendicular to the direction of propagation of the laser and another modulation field in the pump direction, which are generated in the field programmable gate array using direct digital synthesis to measure the three components of the magnetic field simultaneously. The spin-exchange relaxation is suppressed in zero field controlled by a feedback system, thus a wide range and excellent accuracy of three-axis vector atomic magnetometer response is obtained. Consequently, the transverse magnetic field sensitivity of 350 fT/Hz1/2and longitudinal field sensitivity of 3pT/Hz1/2are achieved with a dynamic range of 60000 nT. This sensor with compact size, wide range and high sensitivity is particularly suitable for geomagnetic observatory and space exploration.

IEEE Sensors Journal•Sep 13, 2021•14 citations

Miniaturized atomic magnetometer employing pump-beam modulation

Ziqian Yue, Junjian Tang, Yueyang Zhai

Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).

Advanced Sensor Systems and Applications•Oct 11, 2024•0 citations

CPT Magnetometer with Atomic Energy Level Modulation

Liu Guo-Bin, Runchang Du, Liu Chao-Yang +1 more

We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87 Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.

Chinese Physics Letters•Feb 1, 2008•17 citations

Feedback Methods for Vector Measurements Using an All-Optical Atomic Magnetometer

Michael Bulatowicz, Jonas Tost, Thad G Walker

In this work, we look to compare three methods of feedback for the ultimate purpose of measuring the transverse vector components of a magnetic field using a synchronous light-pulse atomic scalar magnetometer with a few tens of fT/Hz sensitivity in Earth-field-scale magnetic environments. By applying modulation in the magnetic field to orthogonal axes, the respective vector components may, in principle, be separated from the scalar measurement. Success of this technique depends in significant part on the ability to measure and respond to these perturbations with low measurement uncertainty. Using high-speed least-squares fitting, the phase response of the atomic spins relative to the first harmonic of the optical pump pulse repetition rate is monitored and correspondingly adjusted into resonance with the natural Larmor precession frequency. This paper seeks to motivate and compare three distinct methods of feedback for this purpose. As a first step toward the full development of this technique, the present work uses a simplified version with modulation applied only along the bias field. All three methods investigated herein are shown to provide results that match well with the scalar magnetometer measurements and to depend on both the applied modulation amplitude and optimal feedback response to achieve low relative uncertainty.

Sensors•Apr 25, 2023•4 citations
We present the electronics developed for a sensitive and stable atomic vector magnetometer used in low-field detections. These electronics are required to be not only highly reliable and sophisticated for signal processing but also compact in size and low cost in resource consumption for the purpose of miniaturization. In addition, this magnetometer works with multiple modulations, where the interferences between harmonics of modulation fields often disturb the long-term measurements of the sensor. We work out a robust method to eliminate this problem by choosing the modulation frequencies with separations to match the minimum response points of the low-pass filters used in the demodulation processes. We validate the performance of the electronics and the frequency-selection scheme of the modulation fields with corresponding experimental results.
This paper presents a compact low-temperature atomic vector magnetometer for weak-field measurements, using an atomic cell containing two orthogonal multipass cavities. At the working temperature of $75{\phantom{\rule{0.1em}{0ex}}}^{\ensuremath{\circ}}\mathrm{C}$, the magnetic field sensitivities at all three axes are better than $45\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$ at 10 Hz limited by photon noise, and $85\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$ at 0.1 Hz. This sensor also shows measurement stabilities better than 1.5 pT at three axes for an integration time of 104s{10}^{4}\phantom{\rule{0.2em}{0ex}}\mathrm{s}104s, even with the laser frequency unlocked. The sensor response to a rotation is demonstrated, which is also developed to measure the effective gyromagnetic ratio of atoms in this sensor when the bias field is nulled. This magnetometer makes an important step towards long-term stable measurements and calibrations of ultralow fields.
Atomic magnetometers are highly sensitive instruments widely used for measurements of weak magnetic field. Extracting vector information while maintaining high-precision scalar detection has become the trend in atomic magnetometer development. We introduce a vector atomic magnetometer containing a 5 mm-thick microfabricated vapor cell operating in free-induction-decay mode. By employing orthogonal modulation techniques, the system achieves high-precision in-plane vector magnetic field measurements. The high-precision vector magnetic field measurements are demonstrated in the x–z plane. The sensitivity of the total field detection in the miniaturized atomic magnetometer is 30 pT·Hz−1/2 @11 µT. The average angular error of the decoupled measurement is as low as 4.7 mrad @7.6 µT for vector magnetic fields, providing a new approach for vector magnetic field measurement in miniaturized atomic magnetometers.
A miniature wide-range three-axis vector atomic magnetometer under spin-exchange relaxation-free regime has been developed. With a cylindrical vapor cell of size 10 mm in diameter and length, we have constructed a single-beam configuration through a polarization-maintaining fiber carrying the laser beam to the sensor and a multimode fiber guiding the transmitted light field to the photodiode. A rotating field on the plane perpendicular to the direction of propagation of the laser and another modulation field in the pump direction, which are generated in the field programmable gate array using direct digital synthesis to measure the three components of the magnetic field simultaneously. The spin-exchange relaxation is suppressed in zero field controlled by a feedback system, thus a wide range and excellent accuracy of three-axis vector atomic magnetometer response is obtained. Consequently, the transverse magnetic field sensitivity of 350 fT/Hz1/2and longitudinal field sensitivity of 3pT/Hz1/2are achieved with a dynamic range of 60000 nT. This sensor with compact size, wide range and high sensitivity is particularly suitable for geomagnetic observatory and space exploration.
Atomic magnetometers with magnetic field modulation have emerged as pivotal sensors for biomagnetic measurements. However, challenges such as crosstalk between adjacent modulation fields and the complexity of signal circuitry become increasingly serious in the development of array-based equipment with the magnetometers, especially in the miniaturized atomic magnetometer. This paper proposes an all-optical, fully integrated fiber-coupled atomic magnetometer that employs pump beam modulation. A miniaturized atomic magnetometer with a volume of 10 cm³ has been designed, incorporating an active measurement area of 3 × 3 × 3 mm3. The magnetometer operates in the spinexchange relaxation-free (SERF) regime with an 87Rb vapor cell. An amplitude-modulated pump beam directly modulates the rubidium atomic ensembles, rather than the magnetic field modulation. The optical rotation angle is detected by an unmodulated probe beam oriented orthogonally to the pump beam. In light of the discontinuous pumping characteristics, we developed a modified theoretical model to clarify the output response of the proposed atomic magnetometer. The experimental results demonstrate that the new design achieves the same sensitivity as conventional magnetometer configurations with a smaller volume and without crosstalk of the magnetic field. This research highlights the significant potential for advancing the development of highly sensitive, miniaturized atomic magnetometers, making them particularly suitable for applications in magnetocardiography (MCG) and magnetoencephalography (MEG).
We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87 Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.
In this work, we look to compare three methods of feedback for the ultimate purpose of measuring the transverse vector components of a magnetic field using a synchronous light-pulse atomic scalar magnetometer with a few tens of fT/Hz sensitivity in Earth-field-scale magnetic environments. By applying modulation in the magnetic field to orthogonal axes, the respective vector components may, in principle, be separated from the scalar measurement. Success of this technique depends in significant part on the ability to measure and respond to these perturbations with low measurement uncertainty. Using high-speed least-squares fitting, the phase response of the atomic spins relative to the first harmonic of the optical pump pulse repetition rate is monitored and correspondingly adjusted into resonance with the natural Larmor precession frequency. This paper seeks to motivate and compare three distinct methods of feedback for this purpose. As a first step toward the full development of this technique, the present work uses a simplified version with modulation applied only along the bias field. All three methods investigated herein are shown to provide results that match well with the scalar magnetometer measurements and to depend on both the applied modulation amplitude and optimal feedback response to achieve low relative uncertainty.