Sensitive and Stable Atomic Vector Magnetometer to Detect Weak Fields Using Two Orthogonal Multipass Cavities

S.-Q. Liu, Q.-Q. Yu, Hongwei Zhou, Dong Sheng

Published Apr 21, 2023• 15 citations
arXivHTMLPDF

Abstract

This paper presents a compact low-temperature atomic vector magnetometer for weak-field measurements, using an atomic cell containing two orthogonal multipass cavities. At the working temperature of $75{\phantom{\rule{0.1em}{0ex}}}^{\ensuremath{\circ}}\mathrm{C}$, the magnetic field sensitivities at all three axes are better than $45\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$ at 10 Hz limited by photon noise, and $85\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}$ at 0.1 Hz. This sensor also shows measurement stabilities better than 1.5 pT at three axes for an integration time of ${10}^{4}\phantom{\rule{0.2em}{0ex}}\mathrm{s}$, even with the laser frequency unlocked. The sensor response to a rotation is demonstrated, which is also developed to measure the effective gyromagnetic ratio of atoms in this sensor when the bias field is nulled. This magnetometer makes an important step towards long-term stable measurements and calibrations of ultralow fields.

DOI
10.1103/physrevapplied.19.044062

Related papers

Vector Atomic Magnetometer with Free Induction Decay Detection Based on a Microfabricated Vapor Cell

Pengbo Jiang, Qi Li, Jianan Qin +1 more

Atomic magnetometers are highly sensitive instruments widely used for measurements of weak magnetic field. Extracting vector information while maintaining high-precision scalar detection has become the trend in atomic magnetometer development. We introduce a vector atomic magnetometer containing a 5 mm-thick microfabricated vapor cell operating in free-induction-decay mode. By employing orthogonal modulation techniques, the system achieves high-precision in-plane vector magnetic field measurements. The high-precision vector magnetic field measurements are demonstrated in the x–z plane. The sensitivity of the total field detection in the miniaturized atomic magnetometer is 30 pT·Hz−1/2 @11 µT. The average angular error of the decoupled measurement is as low as 4.7 mrad @7.6 µT for vector magnetic fields, providing a new approach for vector magnetic field measurement in miniaturized atomic magnetometers.

Micromachines•Dec 30, 2024•2 citations

Signal-processing electronics for stable and sensitive weak-field atomic vector magnetometers

Hongwei Zhou, X.-K. Wang, S.-Q. Liu +7 more

We present the electronics developed for a sensitive and stable atomic vector magnetometer used in low-field detections. These electronics are required to be not only highly reliable and sophisticated for signal processing but also compact in size and low cost in resource consumption for the purpose of miniaturization. In addition, this magnetometer works with multiple modulations, where the interferences between harmonics of modulation fields often disturb the long-term measurements of the sensor. We work out a robust method to eliminate this problem by choosing the modulation frequencies with separations to match the minimum response points of the low-pass filters used in the demodulation processes. We validate the performance of the electronics and the frequency-selection scheme of the modulation fields with corresponding experimental results.

Review of Scientific Instruments•May 1, 2023•0 citations

An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer

Shengran Su, Zhen-Yuan Xu, Xiang He +6 more

Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.

Sensors•Mar 15, 2023•16 citations

Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

Yibo Qi, Bo Li, Shuying Wang +3 more

Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz$^{1/2}$) was 1.89 times that of the single-pass configuration (3.4 fT/Hz$^{1/2}$), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•19 citations

Herriott-cavity-assisted all-optical atomic vector magnetometer

B. Cai, Chongyan Hao, Zheru Qiu +3 more

We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at $^{85}\mathrm{Rb}$ and $^{87}\mathrm{Rb}$ Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.

arXiv:2005.11196•Physical Review A•May 28, 2020•36 citations

Dead-zone-free free-induction-decay alkali-metal atomic magnetometer

X.-K. Wang, J. He, HH Deng +2 more

The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead-zone-free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell-Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass-cavity-assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross-talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three-dimensional space, and a field sensitivity better than 80 ${\mathrm{fT}/\mathrm{Hz}}^{1/2}$ over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed-loop mode by feeding back the real-time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work pave the way towards a sensitive vector FID magnetometer.

arXiv:2609.04847•Physical Review A•Sep 8, 2026•0 citations
This paper presents a compact low-temperature atomic vector magnetometer for weak-field measurements, using an atomic cell containing two orthogonal multipass cavities. At the working temperature of 75\ensuremath∘C75{\phantom{\rule{0.1em}{0ex}}}^{\ensuremath{\circ}}\mathrm{C}75\ensuremath∘C, the magnetic field sensitivities at all three axes are better than 45fTHz\ensuremath−1/245\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}45fTHz\ensuremath−1/2 at 10 Hz limited by photon noise, and 85fTHz\ensuremath−1/285\phantom{\rule{0.2em}{0ex}}\mathrm{fT}\phantom{\rule{0.2em}{0ex}}{\mathrm{Hz}}^{\ensuremath{-}1/2}85fTHz\ensuremath−1/2 at 0.1 Hz. This sensor also shows measurement stabilities better than 1.5 pT at three axes for an integration time of 104s{10}^{4}\phantom{\rule{0.2em}{0ex}}\mathrm{s}104s, even with the laser frequency unlocked. The sensor response to a rotation is demonstrated, which is also developed to measure the effective gyromagnetic ratio of atoms in this sensor when the bias field is nulled. This magnetometer makes an important step towards long-term stable measurements and calibrations of ultralow fields.
Atomic magnetometers are highly sensitive instruments widely used for measurements of weak magnetic field. Extracting vector information while maintaining high-precision scalar detection has become the trend in atomic magnetometer development. We introduce a vector atomic magnetometer containing a 5 mm-thick microfabricated vapor cell operating in free-induction-decay mode. By employing orthogonal modulation techniques, the system achieves high-precision in-plane vector magnetic field measurements. The high-precision vector magnetic field measurements are demonstrated in the x–z plane. The sensitivity of the total field detection in the miniaturized atomic magnetometer is 30 pT·Hz−1/2 @11 µT. The average angular error of the decoupled measurement is as low as 4.7 mrad @7.6 µT for vector magnetic fields, providing a new approach for vector magnetic field measurement in miniaturized atomic magnetometers.
We present the electronics developed for a sensitive and stable atomic vector magnetometer used in low-field detections. These electronics are required to be not only highly reliable and sophisticated for signal processing but also compact in size and low cost in resource consumption for the purpose of miniaturization. In addition, this magnetometer works with multiple modulations, where the interferences between harmonics of modulation fields often disturb the long-term measurements of the sensor. We work out a robust method to eliminate this problem by choosing the modulation frequencies with separations to match the minimum response points of the low-pass filters used in the demodulation processes. We validate the performance of the electronics and the frequency-selection scheme of the modulation fields with corresponding experimental results.
Three-axis atomic magnetometers have great advantages for interpreting information conveyed by magnetic fields. Here, we demonstrate a compact construction of a three-axis vector atomic magnetometer. The magnetometer is operated with a single laser beam and with a specially designed triangular 87Rb vapor cell (side length is 5 mm). The ability of three-axis measurement is realized by reflecting the light beam in the cell chamber under high pressure, so that the atoms before and after reflection are polarized along two different directions. It achieves a sensitivity of 40 fT/Hz in x-axis, 20 fT/Hz in y-axis, and 30 fT/Hz in z-axis under spin-exchange relaxation-free regime. The crosstalk effect between different axes is proven to be little in this configuration. The sensor configuration here is expected to form further values, especially for vector biomagnetism measurement, clinical diagnosis, and field source reconstruction.
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz1/2^{1/2}1/2) was 1.89 times that of the single-pass configuration (3.4 fT/Hz1/2^{1/2}1/2), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at 85Rb^{85}\mathrm{Rb}85Rb and 87Rb^{87}\mathrm{Rb}87Rb Larmor frequencies, respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100 mG to 500 mG, and demonstrate a field angle sensitivity better than 10 $\ensuremath{\mu}\mathrm{rad}/{\mathrm{Hz}}^{1/2}$ above 10 Hz.
The detection dead zone is an important systematic limitation in scalar atomic magnetometers, constraining their practical utility. In this work, we demonstrate a sensitive dead-zone-free scalar magnetometer by integrating previously established techniques into a FID magnetometer based on Bell-Bloom optical pumping. The dead zone is eliminated by inserting a reflecting mirror within a multipass-cavity-assisted atomic cell, which folds the optical beam into orthogonal paths. Our analysis reveals that interregion cross-talk is essential for interpreting the resulted experimental signals. The sensor exhibits oscillation signal amplitude variations within a factor of three across all orientations in three-dimensional space, and a field sensitivity better than 80 fT/Hz1/2{\mathrm{fT}/\mathrm{Hz}}^{1/2}fT/Hz1/2 over the full space. We further characterize the heading error in the geomagnetic field range, where experimental results agree with theoretical predictions within 0.7 nT. Additionally, the sensor can operate in a closed-loop mode by feeding back the real-time frequency extracted from the FID signal to modulate the pump beam, we characterize the magnetic field slew rate of the sensor. This work pave the way towards a sensitive vector FID magnetometer.