Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Laser, Optics and Optoelectronic Technology (LOPET)

Precise modulation of beam deflection via weak measurement

Xu Han

Published Oct 14, 2022• 0 citations
Publisher

Abstract

Weak measurement technology can be used to achieve ultra-precision modulation of variables. Based on this, to achieve precise modulation of beam deflection, we establish a model of beam propagation using weak measurement, theoretically deduce the general formula of the deflection angle, and illustrate the general process of precise modulation of the angular shift of the beam. By controlling the post-selection state of the weak measurement, the angular shift of the beam can be precisely regulated. The deflection angle is proportional to the imaginary part of the weak value. We describe a simulation and discuss how precise angle tuning can be achieved by controlling experimental parameters.

DOI
10.1117/12.2648252

Related papers

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•6 citations

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

Sang‐Joon Park, Hyoung Joo Kim, Jaewoo Noh

We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

Journal of the Optical Society of Korea•Sep 25, 2012•3 citations

Experimentally Quantifying the Advantages of Weak-Values-Based Metrology

Gerardo I. Viza, Julián Martínez-Rincón, Gabriel Alves +2 more

We measure optical beam deflections both using a weak-values technique and by focusing. By introducing controlled modulations, the WVT outperforms focusing. Post-selecting on 1\% of the photons, we obtain 99\% of the available Fisher information.

Conference on Lasers and Electro-Optics•Jan 1, 2015•4 citations

Retaining high precision and sensitivity for an extended range of phase estimation via modulated weak measurement

Zhaoxue Li, Jiangdong Qiu, Linguo Xie +5 more

We theoretically propose and experimentally demonstrate a modulated weak measurement scheme that permits a precise estimation of the extended phase shift. By choosing the frequency and the total post-selected light intensity as the input and output meter variables, respectively, a linear weak measurement model is established that is especially applicable to precise phase estimation. By performing a time-delay-dependent modulation strategy based on the feedback modulation of the experimental outcome, both the high phase-sensitivity and measurement precision can be retained. We have achieved a precision at the order of ∼10−5 rad that can be effectively retained with an increase in the measured phase.

Applied Physics Letters•Nov 5, 2018•15 citations

On the validity of weak measurement applied for precision measurement

Yuichiro Mori, Jaeha Lee, Izumi Tsutsui

We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.

arXiv:1901.06831•Journal of Physics B Atomic Molecular and Optical Physics•Nov 25, 2019•12 citations

Ultra-small time-delay estimation via a weak measurement technique with post-selection

Chen Fang, Jing-Zheng Huang, Yang Yu +2 more

Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment.

arXiv:1509.04003•Journal of Physics B Atomic Molecular and Optical Physics•Aug 10, 2016•51 citations
Weak measurement technology can be used to achieve ultra-precision modulation of variables. Based on this, to achieve precise modulation of beam deflection, we establish a model of beam propagation using weak measurement, theoretically deduce the general formula of the deflection angle, and illustrate the general process of precise modulation of the angular shift of the beam. By controlling the post-selection state of the weak measurement, the angular shift of the beam can be precisely regulated. The deflection angle is proportional to the imaginary part of the weak value. We describe a simulation and discuss how precise angle tuning can be achieved by controlling experimental parameters.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
We theoretically propose and experimentally demonstrate a modulated weak measurement scheme that permits a precise estimation of the extended phase shift. By choosing the frequency and the total post-selected light intensity as the input and output meter variables, respectively, a linear weak measurement model is established that is especially applicable to precise phase estimation. By performing a time-delay-dependent modulation strategy based on the feedback modulation of the experimental outcome, both the high phase-sensitivity and measurement precision can be retained. We have achieved a precision at the order of ∼10−5 rad that can be effectively retained with an increase in the measured phase.
We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.
Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment.