Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1901.06831 · Journal of Physics B Atomic Molecular and Optical Physics

On the validity of weak measurement applied for precision measurement

Yuichiro Mori, Jaeha Lee, Izumi Tsutsui

Published Oct 28, 2019• 7 citations
arXivHTMLPDF

Abstract

Abstract We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.

DOI
10.1088/1361-6455/ab5200

Related papers

On the validity of weak measurement applied for precision measurement

Yuichiro Mori, Jaeha Lee, Izumi Tsutsui

We present a general framework of examining the validity of weak measurement -- the standard procedure to acquire Aharonov's weak value -- which has been used intensively in recent years for precision measurement, taking advantage of the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten's detection measurement of the spin Hall effect of light and Dixon's ultra sensitive beam deflection measurement. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.

•Jan 1, 2020•7 citations

Experimental Ultra-small Longitudinal Phase Estimation via Weak Measurement Amplification

Mengjun Hu, Xiao‐Min Hu, Bi‐Heng Liu +4 more

Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.

•Jan 1, 2018•2 citations

Weak value and measurement in precision sensing

Junfan Zhu, Ling Ye, Yifan Wang +5 more

Weak measurement refers to a type of quantum measurement that disturbs the system very little. In the framework of weak measurement, Aharonov, Albert, and Vaidman introduced the concept of postselection and thereby defined the weak value. In recent research, weak-value measurement (WVM) has offered a novel perspective for studying intricate problems in quantum mechanics, leading to many conceptual breakthroughs. More importantly in practice, WVM has shown an unprecedented impact on precision sensing. In this review, we begin by presenting the fundamental theory of WVM based on quantum parameter estimation, from which the effects of weak-value amplification and weak-coupling amplification can be derived. The two effects can significantly improve the precision in various sensing schemes based on WVM. We point out the technical advantages that enable the WVM schemes to outperform the conventional ones under the same measurement conditions. Notably, the capability of information compression is underscored, which is garnering increasing attention in the field of quantum metrology. This review aims to show the possibility for broadening the application of WVM to address more critical problems, and on the other hand, for leveraging its advantages to accomplish tasks that are currently unattainable, such that WVM could play a more important role in the future of precision sensing.

Applied Physics Reviews•May 6, 2025•13 citations

Beating Standard Quantum Limit with Weak Measurement

Geng Chen, Peng Yin, Wen-Hao Zhang +3 more

Weak measurements have been under intensive investigation in both experiment and theory. Numerous experiments have indicated that the amplified meter shift is produced by the post-selection, yielding an improved precision compared to conventional methods. However, this amplification effect comes at the cost of a reduced rate of acquiring data, which leads to an increasing uncertainty to determine the level of meter shift. From this point of view, a number of theoretical works have suggested that weak measurements cannot improve the precision, or even damage the metrology information due to the post-selection. In this review, we give a comprehensive analysis of the weak measurements to justify their positive effect on prompting measurement precision. As a further step, we introduce two modified weak measurement protocols to boost the precision beyond the standard quantum limit. Compared to previous works beating the standard quantum limit, these protocols are free of using entangled or squeezed states. The achieved precision outperforms that of the conventional method by two orders of magnitude and attains a practical Heisenberg scaling up to n=106 photons.

Entropy•Mar 16, 2021•23 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•5 citations

Weak value amplification in high energy physics: A case study for precision measurement of CP violation in B meson decays

S. Higashino, Yuichiro Mori, Y. Takubo +3 more

The technique of weak value amplification, proposed by Aharonov et al. in 1988, has been applied for various fields of physics for the purpose of precision measurement, which is made possible by exploiting the freedom of ``postselection'' specifying actively the final state in the physical process. Here we report the feasibility of utilizing the technique of weak value amplification in high-energy particle physics, especially in measuring the $CP$-violating parameters in $B$ meson decays, where the effective lifetime of the decay mode is expected to be prolonged statistically due to the postselection. Our analysis shows that, when adopted in the Belle II experiment at the SuperKEKB collider, the effective lifetime may be prolonged up to 2.6 times, and that the measurement precision of the $CP$-violating parameters will also be improved by its effect.

arXiv:2011.07560•Physical review. D/Physical review. D.•Aug 9, 2021•2 citations
Abstract We present a general framework of examining the validity of weak measurement—the standard procedure to acquire Aharonov’s weak value—which has been used intensively in recent years for precision measurement, exploiting the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten’s detection measurement of the spin Hall effect of light [Hosten and Kwiat 2008 Science 319 787] and Dixon’s ultra sensitive beam deflection measurement [Dixon et al 2009 Phys. Rev. Lett. 102 173601]. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.
We present a general framework of examining the validity of weak measurement -- the standard procedure to acquire Aharonov's weak value -- which has been used intensively in recent years for precision measurement, taking advantage of the amplification mechanism available for the weak value. Our framework allows one to deal systematically with various causes of uncertainties intrinsic to the actual measurement process as well as those found in the theoretical analysis employed to describe the system. Using our framework, we examine in detail the two seminal experiments, Hosten's detection measurement of the spin Hall effect of light and Dixon's ultra sensitive beam deflection measurement. Our analysis shows that their results are well within the range of amplification (actually in the vicinity of the optimal point) where the weak measurements are valid. This suggests that our framework is both practical and sound, and may be useful to determine beforehand the possible extent of amplification in the future weak measurement experiments.
Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.
Weak measurement refers to a type of quantum measurement that disturbs the system very little. In the framework of weak measurement, Aharonov, Albert, and Vaidman introduced the concept of postselection and thereby defined the weak value. In recent research, weak-value measurement (WVM) has offered a novel perspective for studying intricate problems in quantum mechanics, leading to many conceptual breakthroughs. More importantly in practice, WVM has shown an unprecedented impact on precision sensing. In this review, we begin by presenting the fundamental theory of WVM based on quantum parameter estimation, from which the effects of weak-value amplification and weak-coupling amplification can be derived. The two effects can significantly improve the precision in various sensing schemes based on WVM. We point out the technical advantages that enable the WVM schemes to outperform the conventional ones under the same measurement conditions. Notably, the capability of information compression is underscored, which is garnering increasing attention in the field of quantum metrology. This review aims to show the possibility for broadening the application of WVM to address more critical problems, and on the other hand, for leveraging its advantages to accomplish tasks that are currently unattainable, such that WVM could play a more important role in the future of precision sensing.
Weak measurements have been under intensive investigation in both experiment and theory. Numerous experiments have indicated that the amplified meter shift is produced by the post-selection, yielding an improved precision compared to conventional methods. However, this amplification effect comes at the cost of a reduced rate of acquiring data, which leads to an increasing uncertainty to determine the level of meter shift. From this point of view, a number of theoretical works have suggested that weak measurements cannot improve the precision, or even damage the metrology information due to the post-selection. In this review, we give a comprehensive analysis of the weak measurements to justify their positive effect on prompting measurement precision. As a further step, we introduce two modified weak measurement protocols to boost the precision beyond the standard quantum limit. Compared to previous works beating the standard quantum limit, these protocols are free of using entangled or squeezed states. The achieved precision outperforms that of the conventional method by two orders of magnitude and attains a practical Heisenberg scaling up to n=106 photons.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
The technique of weak value amplification, proposed by Aharonov et al. in 1988, has been applied for various fields of physics for the purpose of precision measurement, which is made possible by exploiting the freedom of ``postselection'' specifying actively the final state in the physical process. Here we report the feasibility of utilizing the technique of weak value amplification in high-energy particle physics, especially in measuring the CPCPCP-violating parameters in BBB meson decays, where the effective lifetime of the decay mode is expected to be prolonged statistically due to the postselection. Our analysis shows that, when adopted in the Belle II experiment at the SuperKEKB collider, the effective lifetime may be prolonged up to 2.6 times, and that the measurement precision of the CPCPCP-violating parameters will also be improved by its effect.