arXiv:1509.04003 · Journal of Physics B Atomic Molecular and Optical Physics

Ultra-small time-delay estimation via a weak measurement technique with post-selection

Chen Fang, Jing-Zheng Huang, Yang Yu, Qinzheng Li, Guihua Zeng

Published Aug 10, 2016• 45 citations
arXivHTMLPDF

Abstract

Abstract Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment.

DOI
10.1088/0953-4075/49/17/175501

Related papers

Ultra-small phase estimation via weak measurement with postselection: A comparison of joint weak measurement and weak value amplification

Fang Chen, Jingzheng Huang, Yang Yu +2 more

We derive a general theory for the joint weak measurement with arbitrary postselection and employ it in the time-delay measurement. Especially, we study two special cases, i.e., the balanced and unbalanced postselection regimes, and present an experiment to verify the theoretical results. The experimental results show that under similar conditions, the signal-to-noise ratio of using joint weak measurement scheme remains higher than 12 dB when the measured time-delay is smaller the ultimate precision limit of the weak-value amplification scheme. Moreover, the joint weak measurement scheme is robust to the misalignment errors and the wavelength-dependency of optical components, which indicates its advantage of improving the measurement precision with convenient laboratory equipments.

•Sep 14, 2015•2 citations

Realization of ultra-small stress birefringence detection with weak-value amplification technique

Yongsheng Wang, Shizhen Chen, Shuangchun Wen +1 more

How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.

Applied Physics Letters•Apr 19, 2021•20 citations

Experimental Ultra-small Longitudinal Phase Estimation via Weak Measurement Amplification

Mengjun Hu, Xiao‐Min Hu, Bi‐Heng Liu +4 more

Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.

•Jan 1, 2018•2 citations

Measuring Ultrasmall Time Delays of Light by Joint Weak Measurements

Grégory Strübi, Christoph Bruder

We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.

arXiv:1301.5846•Physical Review Letters•Feb 22, 2013•134 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•5 citations

Optimal pre- and post-selections of weak measurements for precision parameter estimation

Xiong Liu, Xiaodong Qiu, Linguo Xie +4 more

Weak measurements, which offer a significant signal enhancement with pre- and post-selections, have proven to be powerful for precision metrology. However, the measured precision of the parameter of interest is always limited by the post-selection-induced probe loss, especially in the presence of technical noise. In this paper, we investigate the optimal pre- and post-selections of weak measurements for precision metrology in the presence of technical noise. While weak measurements apply more generally, we experimentally measure the spin splitting induced by the spin Hall effect of light (SHEL) to approach this issue. The highest measured precision of the spin splitting can be obtained with the post-selected state in the nonlinear intermediate regime. Surprisingly, the pre- and post-selections for the largest weak-value amplification are incapable of estimation of the spin splitting, since the amplified shift is independent of the spin splitting. Our results are not restricted to the SHEL and could be applied to other parameter estimations with weak measurements.

Journal of Applied Physics•May 28, 2017•5 citations
Abstract Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment.
We derive a general theory for the joint weak measurement with arbitrary postselection and employ it in the time-delay measurement. Especially, we study two special cases, i.e., the balanced and unbalanced postselection regimes, and present an experiment to verify the theoretical results. The experimental results show that under similar conditions, the signal-to-noise ratio of using joint weak measurement scheme remains higher than 12 dB when the measured time-delay is smaller the ultimate precision limit of the weak-value amplification scheme. Moreover, the joint weak measurement scheme is robust to the misalignment errors and the wavelength-dependency of optical components, which indicates its advantage of improving the measurement precision with convenient laboratory equipments.
How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.
Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.
We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
Weak measurements, which offer a significant signal enhancement with pre- and post-selections, have proven to be powerful for precision metrology. However, the measured precision of the parameter of interest is always limited by the post-selection-induced probe loss, especially in the presence of technical noise. In this paper, we investigate the optimal pre- and post-selections of weak measurements for precision metrology in the presence of technical noise. While weak measurements apply more generally, we experimentally measure the spin splitting induced by the spin Hall effect of light (SHEL) to approach this issue. The highest measured precision of the spin splitting can be obtained with the post-selected state in the nonlinear intermediate regime. Surprisingly, the pre- and post-selections for the largest weak-value amplification are incapable of estimation of the spin splitting, since the amplified shift is independent of the spin splitting. Our results are not restricted to the SHEL and could be applied to other parameter estimations with weak measurements.