Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Ultra-small phase estimation via weak measurement with postselection: A comparison of joint weak measurement and weak value amplification

Fang Chen, Jingzheng Huang, Yang Yu, Qinzheng Li, Guihua Zeng

Published Sep 14, 2015• 2 citations
OpenAlex

Abstract

We derive a general theory for the joint weak measurement with arbitrary postselection and employ it in the time-delay measurement. Especially, we study two special cases, i.e., the balanced and unbalanced postselection regimes, and present an experiment to verify the theoretical results. The experimental results show that under similar conditions, the signal-to-noise ratio of using joint weak measurement scheme remains higher than 12 dB when the measured time-delay is smaller the ultimate precision limit of the weak-value amplification scheme. Moreover, the joint weak measurement scheme is robust to the misalignment errors and the wavelength-dependency of optical components, which indicates its advantage of improving the measurement precision with convenient laboratory equipments.

Related papers

Ultra-small time-delay estimation via a weak measurement technique with post-selection

Chen Fang, Jing-Zheng Huang, Yang Yu +2 more

Abstract Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment.

arXiv:1509.04003•Journal of Physics B Atomic Molecular and Optical Physics•Aug 10, 2016•45 citations

Measuring Ultrasmall Time Delays of Light by Joint Weak Measurements

Grégory Strübi, Christoph Bruder

We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.

arXiv:1301.5846•Physical Review Letters•Feb 22, 2013•134 citations

Experimental Ultra-small Longitudinal Phase Estimation via Weak Measurement Amplification

Mengjun Hu, Xiao‐Min Hu, Bi‐Heng Liu +4 more

Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.

•Jan 1, 2018•2 citations

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•8 citations

Adaptive weak-value amplification with adjustable postselection

Fei Li, Jingzheng Huang, Guihua Zeng

Weak-value amplification (WVA) has recently become an important technique for parameter estimation, owing to its ability to enhance the signal-to-noise ratio by amplifying extremely small signals with proper postselection strategies. In this paper, we propose an adaptive WVA scheme to achieve the highest Fisher information when using an unbalanced pointer. Different from previous schemes, the adaptive WVA scheme is associated with a real-time update on the postselection states with the help of feedback information from the outcomes, and the ``extremely small'' condition set on the parameter of interest is relaxed. By applying this scheme to a time-delay measurement scenario, we show by numerical simulation that the precision achieved in our scheme is several times higher than the standard WVA scheme. Our result might open a path for improving the WVA technique in a more flexible and robust way.

arXiv:1803.09421•Physical Review A•Sep 15, 2017•23 citations

Realization of ultra-small stress birefringence detection with weak-value amplification technique

Yongsheng Wang, Shizhen Chen, Shuangchun Wen +1 more

How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.

Applied Physics Letters•Apr 19, 2021•20 citations
We derive a general theory for the joint weak measurement with arbitrary postselection and employ it in the time-delay measurement. Especially, we study two special cases, i.e., the balanced and unbalanced postselection regimes, and present an experiment to verify the theoretical results. The experimental results show that under similar conditions, the signal-to-noise ratio of using joint weak measurement scheme remains higher than 12 dB when the measured time-delay is smaller the ultimate precision limit of the weak-value amplification scheme. Moreover, the joint weak measurement scheme is robust to the misalignment errors and the wavelength-dependency of optical components, which indicates its advantage of improving the measurement precision with convenient laboratory equipments.
Abstract Weak measurement is a novel technique for parameter estimation with higher precision. In this paper we develop a general theory for the parameter estimation based on a weak measurement technique with arbitrary post-selection. The weak-value amplification model and the joint weak measurement model are two special cases in our theory. Applying the developed theory, time-delay estimation is investigated in both theory and experiments. The experimental results show that when the time delay is ultra-small, the joint weak measurement scheme outperforms the weak-value amplification scheme, and is robust against not only misalignment errors but also the wavelength dependence of the optical components. These results are consistent with theoretical predictions that have not been previously verified by any experiment.
We propose to use weak measurements away from the weak-value amplification regime to carry out precision measurements of time delays of light. Our scheme is robust to several sources of noise that are shown to only limit the relative precision of the measurement. Thus, they do not set a limit on the smallest measurable phase shift, contrary to standard interferometry and weak-value-based measurement techniques. Our idea is not restricted to phase-shift measurements and could be used to measure other small effects using a similar protocol.
Weak value amplification has been applied to various small physical quantities estimation, however there still lacks a practical feasible protocol to amplify ultra-small longitudinal phase, which is of importance in high precision measurement. Very recently, a different amplification protocol within the framework of weak measurements is proposed to solve this problem, which is capable of measuring any ultra-small longitudinal phase signal that conventional interferometry tries to do. Here we experimentally demonstrate this weak measurements amplification protocol of ultra-small longitudinal phase and realize one order of magnitude amplification in the same technical condition, which verifies the validity of the protocol and show higher precision and sensitivity than conventional interferometry. Our results significantly broaden the area of applications of weak measurements and may play an important role in high precision measurements.
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.
Weak-value amplification (WVA) has recently become an important technique for parameter estimation, owing to its ability to enhance the signal-to-noise ratio by amplifying extremely small signals with proper postselection strategies. In this paper, we propose an adaptive WVA scheme to achieve the highest Fisher information when using an unbalanced pointer. Different from previous schemes, the adaptive WVA scheme is associated with a real-time update on the postselection states with the help of feedback information from the outcomes, and the ``extremely small'' condition set on the parameter of interest is relaxed. By applying this scheme to a time-delay measurement scenario, we show by numerical simulation that the precision achieved in our scheme is several times higher than the standard WVA scheme. Our result might open a path for improving the WVA technique in a more flexible and robust way.
How to realize the detection of tiny birefringence is an important but challenging issue for investigations and applications in optics. In weak measurements, weak-value amplification has been widely applied to the precise estimation of time delay. Here, we show that the linear amplification in weak measurements has the potential to outperform standard weak-value amplification for ultra-small parameter characterization. The higher measurement accuracy in the linear amplification enables us to achieve a measurement of stress-induced birefringence with a high resolution of 5×10−10. Compared with existing methods, the accuracy based on weak measurements for birefringence detection can improve two orders of magnitude. Our method may have important applications in a variety of fields involving the precise measurement of time delay or birefringence.