Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2203.15231 · Physical Review A

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada, Jeff S. Lundeen, Kyle M. Jordan, Huan Chen, Jianqi An

Published Nov 3, 2022• 8 citations
arXivHTMLPDF

Abstract

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

DOI
10.1103/physreva.106.053704

Related papers

Mitigating source and detection noises in autocorrelative weak-value amplification

Xiangyun Hu, Jing-Hui Huang, Feifan He +2 more

Weak-value amplification (WVA), a postselection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and postselected quantum states, is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in postselection. While prior work established the efficacy of autocorrelative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise (including shot noise and electrical noise). Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA's dual advantage: under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes in- creasingly pronounced as input laser power increases, whereas in detection-limited regimes AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cram\'er-Rao bound. Crucially, this work demonstrates that AWVA improves precision in both high-power (laser-noise-dominated) and photon-starved (detector-noise-dominated) regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.

arXiv:2209.12732•Physical Review A•Oct 2, 2025•1 citation

Real-time analog circuit for auto-correlative weak-value amplification in the time domain

Jing-Hui Huang, Guang-Jun Wang, Xiangyun Hu

The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation, the AWVA requires additional resources compared to SWVA, namely real-time multiplication and integrator modules. We implemented a real-time analog circuit for AWVA using an AD835 multiplier and an NE5532 operational amplifier for the integrator. The circuit was tested using Gaussian pointers in the AWVA scheme, exhibiting sufficient sensitivity for Gaussian pointers with frequencies 200 Hz ≤ f ≤ 20 kHz. Compared to SWVA, AWVA achieves higher accuracy and superior robustness against noise at signal-to-noise ratios (SNRs) of −12 dB ≤ SNR ≤ −4 dB. Beyond quantum metrology, the circuit is applicable to diverse detection schemes for correlated signals.

arXiv:2507.18180•International Conference on Advanced Optics and Photonics Research in Engineering (AOPR)•Dec 2, 2025•0 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•11 citations

Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance

Jing-Hui Huang, Xiang-Yun Hu

We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of $T$ = $0.01-0.1$ s, representing two orders of magnitude variance reduction compared to the $T=300$ s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number $1/N_r$, confirming shot-noise-limited operation with WVA. Furthermore, this $1/N_r$ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime ($>10$ Hz).

quant-pharXiv:2602.17035•Physical Review A•Feb 20, 2026•2 citations

Adaptive weak-value amplification with adjustable postselection

Fei Li, Jingzheng Huang, Guihua Zeng

Weak-value amplification (WVA) has recently become an important technique for parameter estimation, owing to its ability to enhance the signal-to-noise ratio by amplifying extremely small signals with proper postselection strategies. In this paper, we propose an adaptive WVA scheme to achieve the highest Fisher information when using an unbalanced pointer. Different from previous schemes, the adaptive WVA scheme is associated with a real-time update on the postselection states with the help of feedback information from the outcomes, and the ``extremely small'' condition set on the parameter of interest is relaxed. By applying this scheme to a time-delay measurement scenario, we show by numerical simulation that the precision achieved in our scheme is several times higher than the standard WVA scheme. Our result might open a path for improving the WVA technique in a more flexible and robust way.

arXiv:1803.09421•Physical Review A•Sep 15, 2017•23 citations

Fisher information analysis on weak-value-amplification metrology using optical coherent states

Yingxin Liu, Lupei Qin, Xin-Qi Li

The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.

Physical Review A•Aug 30, 2022•20 citations
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) \ensuremathτ\ensuremath{\tau}\ensuremathτ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities \ensuremathτ\ensuremath{\tau}\ensuremathτ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.
Weak-value amplification (WVA), a postselection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and postselected quantum states, is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in postselection. While prior work established the efficacy of autocorrelative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise (including shot noise and electrical noise). Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA's dual advantage: under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes in- creasingly pronounced as input laser power increases, whereas in detection-limited regimes AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cram\'er-Rao bound. Crucially, this work demonstrates that AWVA improves precision in both high-power (laser-noise-dominated) and photon-starved (detector-noise-dominated) regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.
The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation, the AWVA requires additional resources compared to SWVA, namely real-time multiplication and integrator modules. We implemented a real-time analog circuit for AWVA using an AD835 multiplier and an NE5532 operational amplifier for the integrator. The circuit was tested using Gaussian pointers in the AWVA scheme, exhibiting sufficient sensitivity for Gaussian pointers with frequencies 200 Hz ≤ f ≤ 20 kHz. Compared to SWVA, AWVA achieves higher accuracy and superior robustness against noise at signal-to-noise ratios (SNRs) of −12 dB ≤ SNR ≤ −4 dB. Beyond quantum metrology, the circuit is applicable to diverse detection schemes for correlated signals.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.
We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of TTT = 0.01−0.10.01-0.10.01−0.1 s, representing two orders of magnitude variance reduction compared to the T=300T=300T=300 s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number 1/Nr1/N_r1/Nr​, confirming shot-noise-limited operation with WVA. Furthermore, this 1/Nr1/N_r1/Nr​ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime (>10>10>10 Hz).
Weak-value amplification (WVA) has recently become an important technique for parameter estimation, owing to its ability to enhance the signal-to-noise ratio by amplifying extremely small signals with proper postselection strategies. In this paper, we propose an adaptive WVA scheme to achieve the highest Fisher information when using an unbalanced pointer. Different from previous schemes, the adaptive WVA scheme is associated with a real-time update on the postselection states with the help of feedback information from the outcomes, and the ``extremely small'' condition set on the parameter of interest is relaxed. By applying this scheme to a time-delay measurement scenario, we show by numerical simulation that the precision achieved in our scheme is several times higher than the standard WVA scheme. Our result might open a path for improving the WVA technique in a more flexible and robust way.
The weak-value-amplification (WVA) technique has been extensively considered and debated in the field of quantum precision measurement, largely owing to the reduced Fisher information caused by the low probability of successful postselection. In this work we show that, rather than the transverse-spatial-wave-function meter typically considered, using the optical coherent state as a meter, the WVA measurement can outperform the conventional measurement not involving the strategy of postselection. We also show that the postselection procedure involved in the WVA scheme can make a mixture of coherent states work better than a pure coherent state with identical average photon numbers. This is in contrast to the main result proved in the absence of postselection. The postselection strategy can also result in the precision of Heisenberg scaling with the photon numbers without using expensive quantum resources. The present work may stimulate further interest in postselection strategy for quantum precision measurements.