arXiv:2209.12732 · Physical Review A

Mitigating source and detection noises in autocorrelative weak-value amplification

Xiangyun Hu, Jing-Hui Huang, Feifan He, Guang-Jun Wang, Adetunmise C. Dada

Published Oct 2, 2025• 1 citation
arXivHTMLPDF

Abstract

Weak-value amplification (WVA), a postselection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and postselected quantum states, is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in postselection. While prior work established the efficacy of autocorrelative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise (including shot noise and electrical noise). Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA's dual advantage: under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes in- creasingly pronounced as input laser power increases, whereas in detection-limited regimes AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cram\'er-Rao bound. Crucially, this work demonstrates that AWVA improves precision in both high-power (laser-noise-dominated) and photon-starved (detector-noise-dominated) regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.

DOI
10.1103/vr7v-lwtb

Related papers

Autocorrelative weak-value amplification and simulating the protocol under strong Gaussian noise

Jing-Hui Huang, Xiangyun Hu, Adetunmise C. Dada +4 more

By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.

arXiv:2203.15231•Physical Review A•Nov 3, 2022•8 citations

A potential third-generation gravitational-wave detector based on autocorrelative weak-value amplification

Jing-Hui Huang, Feifan He, Xue-Ying Duan +2 more

Abstract Reducing noises and enhancing signal-to-noise ratios (SNRs) have become critical for designing third-generation gravitational-wave (GW) detectors with a GW strain of less than 10 − 23 H z − 1 . In this paper, we propose a potential third-generation GW detector based on autocorrelative weak-value amplification (AWVA) for GW detection with a strain of h g = 4 × 10 − 25 H z − 1 . In our scheme, a GW event induces a phase difference Δ ϕ by passing through a 11-bounce delay line, 10-km arm-length, zero-area Sagnac interferometer illuminated with a 1064-nm laser. Subsequently, Δ ϕ is amplified as the parameter of post-selection by choosing the appropriate pre-selected state and coupling strength in AWVA. In particular, we theoretically investigate the AWVA measurements for GW detection within the frequency band of 200 Hz ⩽ f g ⩽ 800 Hz, considering Gaussian noises with negative-decibel SNRs. The peak response of the AWVA sensitivity κ ( f g ) occurs at frequency f g , m a x = 500 Hz, which falls within the frequency band of interest of the current third-generation GW detectors. Our simulation results indicate that AWVA can demonstrate a measurable sensitivity of the autocorrelation coefficient Θ ( f g ) within the frequency band of interest. Moreover, the robustness of WVA shows promising potential in mitigating the effects of Gaussian noises.

arXiv:2306.06827•Classical and Quantum Gravity•Jul 27, 2023•2 citations

Weak-Value Amplification for Longitudinal Phase Measurements Approaching the Shot-Noise Limit Characterized by Allan Variance

Jing-Hui Huang, Xiang-Yun Hu

We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of $T$ = $0.01-0.1$ s, representing two orders of magnitude variance reduction compared to the $T=300$ s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number $1/N_r$, confirming shot-noise-limited operation with WVA. Furthermore, this $1/N_r$ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime ($>10$ Hz).

quant-pharXiv:2602.17035•Physical Review A•Feb 20, 2026•2 citations

Approaching Quantum-Limited Metrology with Imperfect Detectors by Using Weak-Value Amplification

Liang Xu, Zexuan Liu, Animesh Datta +4 more

Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.

arXiv:2005.03629•Physical Review Letters•Aug 17, 2020•97 citations

Real-time analog circuit for auto-correlative weak-value amplification in the time domain

Jing-Hui Huang, Guang-Jun Wang, Xiangyun Hu

The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation, the AWVA requires additional resources compared to SWVA, namely real-time multiplication and integrator modules. We implemented a real-time analog circuit for AWVA using an AD835 multiplier and an NE5532 operational amplifier for the integrator. The circuit was tested using Gaussian pointers in the AWVA scheme, exhibiting sufficient sensitivity for Gaussian pointers with frequencies 200 Hz ≤ f ≤ 20 kHz. Compared to SWVA, AWVA achieves higher accuracy and superior robustness against noise at signal-to-noise ratios (SNRs) of −12 dB ≤ SNR ≤ −4 dB. Beyond quantum metrology, the circuit is applicable to diverse detection schemes for correlated signals.

arXiv:2507.18180•International Conference on Advanced Optics and Photonics Research in Engineering (AOPR)•Dec 2, 2025•0 citations

Enhancing Interferometry Using Weak Value Amplification with Real Weak Values

Jing-Hui Huang, Kyle M. Jordan, Adetunmise C. Dada +2 more

We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.

arXiv:2404.00531•Physical Review Letters•Feb 27, 2025•11 citations
Weak-value amplification (WVA), a postselection-based technique that amplifies weak physical signals by preparing nearly orthogonal pre- and postselected quantum states, is intrinsically limited by various kinds of technical noise, which distorts amplified weak values, especially when discarding photons in postselection. While prior work established the efficacy of autocorrelative weak-value amplification (AWVA) under Gaussian noise, practical implementations face challenges from band-limited laser-source noise and detection noise (including shot noise and electrical noise). Here, we demonstrate that the AWVA protocol robustly suppresses both laser-power fluctuations and detection noise. Numerical experiments in Simulink further reveal AWVA's dual advantage: under high-power conditions, the noise-reduction superiority of AWVA over WVA becomes in- creasingly pronounced as input laser power increases, whereas in detection-limited regimes AWVA achieves an order-of-magnitude lower uncertainty, closely approaching the Cram'er-Rao bound. Crucially, this work demonstrates that AWVA improves precision in both high-power (laser-noise-dominated) and photon-starved (detector-noise-dominated) regimes, thereby bridging these operating extremes and advancing precision in applications from gravitational-wave detection to hybrid quantum systems.
By choosing more orthogonality between preselection and postselection states, one can significantly improve the sensitivity in general optical quantum metrology based on the weak-value amplification (WVA) approach. However, increasing the orthogonality decreases the probability of detecting photons and makes the weak measurement difficult, especially when the weak measurement is disturbed by strong noise and the pointer is drowned in noise with a negative-decibel signal-to-noise ratio (SNR). In this article we introduce and numerically evaluate a modified weak-measurement protocol with a temporal pointer, namely, the autocorrelative weak-value amplification (AWVA) approach. Specifically, a small longitudinal time delay (tiny phase shift) $\ensuremath{\tau}$ of a Gaussian pulse is measured by implementing two simultaneous autocorrelative weak measurements under Gaussian white noise with different SNRs. The small quantities $\ensuremath{\tau}$ are obtained by measuring the autocorrelation coefficient of the pulses instead of fitting the shift of the mean value of the probe in the standard WVA technique. Simulation results show that the AWVA approach outperforms the standard WVA technique in the time domain with smaller statistical errors, remarkably increasing the precision of weak measurement under a strong noise background.
Abstract Reducing noises and enhancing signal-to-noise ratios (SNRs) have become critical for designing third-generation gravitational-wave (GW) detectors with a GW strain of less than 10 − 23 H z − 1 . In this paper, we propose a potential third-generation GW detector based on autocorrelative weak-value amplification (AWVA) for GW detection with a strain of h g = 4 × 10 − 25 H z − 1 . In our scheme, a GW event induces a phase difference Δ ϕ by passing through a 11-bounce delay line, 10-km arm-length, zero-area Sagnac interferometer illuminated with a 1064-nm laser. Subsequently, Δ ϕ is amplified as the parameter of post-selection by choosing the appropriate pre-selected state and coupling strength in AWVA. In particular, we theoretically investigate the AWVA measurements for GW detection within the frequency band of 200 Hz ⩽ f g ⩽ 800 Hz, considering Gaussian noises with negative-decibel SNRs. The peak response of the AWVA sensitivity κ ( f g ) occurs at frequency f g , m a x = 500 Hz, which falls within the frequency band of interest of the current third-generation GW detectors. Our simulation results indicate that AWVA can demonstrate a measurable sensitivity of the autocorrelation coefficient Θ ( f g ) within the frequency band of interest. Moreover, the robustness of WVA shows promising potential in mitigating the effects of Gaussian noises.
We report a quantitative evaluation of weak-value amplification (WVA) for longitudinal phase measurements using Allan variance analysis. Building on a recent double-slit interferometry experiment with real weak values [Phys. Rev. Lett. 134, 080802 (2025)], our Allan variance analysis demonstrates measurement of a few attosecond time delay approaching the shot noise limit at short averaging intervals of TTT = 0.01−0.10.01-0.10.01−0.1 s, representing two orders of magnitude variance reduction compared to the T=300T=300T=300 s operating point in prior implementations. We demonstrate that the Allan-variance noise floor scales with the inverse of the detected photon number 1/Nr1/N_r1/Nr​, confirming shot-noise-limited operation with WVA. Furthermore, this 1/Nr1/N_r1/Nr​ scaling experimentally validates that WVA can outperform conventional measurement under fixed detected photon number and detector saturation, in the presence of technical noise, as theoretically predicted [Phys. Rev. Lett. 118, 070802 (2017)]. Our results provide rigorous, quantitative evidence of the near-optimal noise performance achievable with WVA, establishing a new benchmark for precision optical metrology. This advancement is particularly relevant to applications such as gravitational-wave detection, where signals predominantly occupy the high-frequency regime (>10>10>10 Hz).
Weak-value amplification (WVA) is a metrological protocol that amplifies ultrasmall physical effects. However, the amplified outcomes necessarily occur with highly suppressed probabilities, leading to the extensive debate on whether the overall measurement precision is improved in comparison to that of conventional measurement (CM). Here, we experimentally demonstrate the unambiguous advantages of WVA that overcome practical limitations including noise and saturation of photodetection and maintain a shot-noise-scaling precision for a large range of input light intensity well beyond the dynamic range of the photodetector. The precision achieved by WVA is 6 times higher than that of CM in our setup. Our results clear the way for the widespread use of WVA in applications involving the measurement of small signals including precision metrology and commercial sensors.
The auto-correlative weak-value amplification (AWVA) technique demonstrates distinct advantages over standard weak-value amplification (SWVA) for quantum parameter estimation. To achieve enhanced precision in real-time parameter estimation, the AWVA requires additional resources compared to SWVA, namely real-time multiplication and integrator modules. We implemented a real-time analog circuit for AWVA using an AD835 multiplier and an NE5532 operational amplifier for the integrator. The circuit was tested using Gaussian pointers in the AWVA scheme, exhibiting sufficient sensitivity for Gaussian pointers with frequencies 200 Hz ≤ f ≤ 20 kHz. Compared to SWVA, AWVA achieves higher accuracy and superior robustness against noise at signal-to-noise ratios (SNRs) of −12 dB ≤ SNR ≤ −4 dB. Beyond quantum metrology, the circuit is applicable to diverse detection schemes for correlated signals.
We introduce an ultrasensitive interferometric protocol that combines weak value amplification (WVA) with traditional interferometry. This protocol WVA+interferometry uses weak value amplification of the relative delay between two paths to enhance interferometric sensitivity. As an example, we demonstrate a proof-of-principle experiment that achieves few-attosecond timing resolution (few nanometer path length resolution) with a double-slit interferometer using only common optical components. Since our example uses only the spatial shift of double-slit interference fringes, its precision is not limited by the timing resolution of the detectors but is instead limited by the fundamental shot noise associated with classical light and the diminished technical noise. We experimentally demonstrate that the signal-to-noise ratio can be improved by one to two orders of magnitude relative to a measurement that does not use WVA. Two key conclusions are drawn: (i) Most conventional interferometric techniques primarily rely on determining the path difference (time delay or longitudinal phase), with their precision constrained by technical noise. Our protocol offers a robust solution for minimizing the technical noise in traditional interferometry, with precision in principle approaching the shot-noise limit. (ii) Although WVA has achieved significant advancements in ultrasensitive longitudinal phase measurement, its applicability is constrained by the need for broad spectral bandwidths and high-resolution spectrometers. Contrary to previous assumptions, we demonstrate that quantum-limited WVA time delay measurements are achievable with narrow band light using real weak values. Thus, the cost-effectiveness and practicality of the proposed WVA+interferometry protocol using narrow band light broaden the scope of WVA applications. This protocol holds potential for broad applications in optical metrology, quantum optics and quantum information, biomedical imaging, and interferometric telescopes for astrophysics.