Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of Korea

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

Sang‐Joon Park, Hyoung Joo Kim, Jaewoo Noh

Published Sep 25, 2012• 2 citations
Publisher

Abstract

We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

DOI
10.3807/josk.2012.16.3.277

Related papers

Deflection Measurements with Weak Values

P. Ben Dixon, David J. Starling, Nathan S. Williams +3 more

We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.

Frontiers in Optics•Jan 1, 2010•0 citations

Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification

P. Ben Dixon, David J. Starling, Andrew N. Jordan +1 more

We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.

arXiv:0906.4828•Physical Review Letters•Apr 27, 2009•771 citations

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

박상준, 김형주, 노재우

•Sep 1, 2012•0 citations

Enhancing the sensitivity of amplification of rotation velocity in Sagnac's interferometer with biased weak measurement

Jing-Hui Huang, Xiangyun Hu, Xue-Ying Duan +1 more

Recently, biased weak measurement(BWM) has shown higher precision than both conventional measurement and standard weak measurement(SWM) in optical metrology. In this paper, we propose a scheme of detecting rotation velocity in Sagnac's interferometer with BWM. In particular, BWM employs an additional reduction of photons in the post-selection by introducing a pre-coupling, and the remaining photons have been shown to be extremely sensitive to the estimated parameter. In addition, our numerical results show that the scheme with BWM can obtain a higher sensitivity than the scheme with SWM.

arXiv:2110.11060•Oct 21, 2021•1 citation

Technical Advantages for Weak-Value Amplification

Julián Martínez-Rincón, Gerardo I. Viza, G. B. Alves +2 more

We consider different types of technical noise in an optical context and show that weak-value amplification techniques (using a small fraction of photons) compare favourably with standard techniques (using all of them). We measure small beam deflections of an optical beam by monitoring the dark port in a Sagnac interferometer (weak-value technique) or by focusing the entire beam onto a split detector (standard technique). In all cases, the weak-value technique performs favourable in precision respect to the standard technique.

Frontiers in Optics•Jan 1, 2015•1 citation

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•5 citations
We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.
We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.
We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.
Recently, biased weak measurement(BWM) has shown higher precision than both conventional measurement and standard weak measurement(SWM) in optical metrology. In this paper, we propose a scheme of detecting rotation velocity in Sagnac's interferometer with BWM. In particular, BWM employs an additional reduction of photons in the post-selection by introducing a pre-coupling, and the remaining photons have been shown to be extremely sensitive to the estimated parameter. In addition, our numerical results show that the scheme with BWM can obtain a higher sensitivity than the scheme with SWM.
We consider different types of technical noise in an optical context and show that weak-value amplification techniques (using a small fraction of photons) compare favourably with standard techniques (using all of them). We measure small beam deflections of an optical beam by monitoring the dark port in a Sagnac interferometer (weak-value technique) or by focusing the entire beam onto a split detector (standard technique). In all cases, the weak-value technique performs favourable in precision respect to the standard technique.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.