Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification

P. Ben Dixon, David J. Starling, Andrew N. Jordan, John C. Howell

Published Apr 27, 2009• 771 citations
arXivHTMLPDF

Abstract

We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.

DOI
10.1103/physrevlett.102.173601

Related papers

Deflection Measurements with Weak Values

P. Ben Dixon, David J. Starling, Nathan S. Williams +3 more

We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.

Frontiers in Optics•Jan 1, 2010•0 citations

Weak Value Measurement of an Optical Beam Deflection in Image Rotating Sagnac Interferometer

Sang‐Joon Park, Hyoung Joo Kim, Jaewoo Noh

We measured small optical beam deflection in an image rotating Sagnac interferometer. We used a weak value measurement scheme that involves a pre-selection, weak perturbation, and a post-selection procedure to obtain the amplified value of beam deflection. The amplification factor of the measured beam deflection varied from 11 to 63 depending on the settings of the post-selection polarizer in front of the photodetector and the settings of polarization compensator in the interferometer.

Journal of the Optical Society of Korea•Sep 25, 2012•2 citations

Generalized framework of weak-value amplification in path interference of polarized light for the enhancement of all possible polarization anisotropy effects

Niladri Modak, B S Athira, Ankit Kumar Singh +1 more

Using the profound interferometric philosophy of weak-value amplification, we propose a simple, general, and robust polarization method for the amplification and quantification of small magnitudes of all possible polarization anisotropy effects in a single experimental embodiment. The approach is experimentally realized by introducing a weak coupling between the polarization degree of freedom of light and the path degree of freedom in a Mach-Zehnder interferometer in the presence of a weak anisotropy effect. Real and imaginary weak-value amplifications of different polarization anisotropy effects are manifested as characteristic changes in the relevant Stokes vector elements at the exit port of the interferometer, which follow orthogonal trajectories in the Poincar\'e sphere. The proof-of-concept experiment demonstrates that by using this scheme, one can faithfully extract and quantify an anisotropy parameter that is smaller than the typical sensitivity of measurement of a given Stokes parameter of a traditional polarimeter by a large weak-value amplification factor. This opens up the possibility of a sample measuring weak-value polarimeter for studying the rich variety of fundamental optical effects and for materials characterization and precision metrology.

arXiv:2002.10093•Physical Review A•May 19, 2021•8 citations

Experimentally quantifying the advantages of weak-value-based metrology

Gerardo I. Viza, Julián Martínez-Rincón, G. B. Alves +2 more

We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on $1%$ of the photons, we obtain $99%$ of the available Fisher information of the beam deflection parameter.

arXiv:1410.8461•Physical Review A•Sep 22, 2015•118 citations

Optimizing the signal-to-noise ratio of a beam-deflection measurement with interferometric weak values

David J. Starling, P. Ben Dixon, Andrew N. Jordan +1 more

The amplification obtained using weak values is quantified through a detailed investigation of the signal-to-noise ratio for an optical beam-deflection measurement. We show that for a given deflection, input power and beam radius, the use of interferometric weak values allows one to obtain the optimum signal-to-noise ratio using a coherent beam. This method has the advantage of reduced technical noise and allows for the use of detectors with a low saturation intensity. We report on an experiment which improves the signal-to-noise ratio for a beam-deflection measurement by a factor of 54 when compared to a measurement using the same beam size and a quantum-limited detector.

arXiv:0910.2410•Physical Review A•Oct 8, 2009•213 citations

Development of an “Interferometric Quasi-Autocollimator”

Matthew D. Turner, Charles A. Hagedorn, Stephan Schlamminger +1 more

We have developed a device that uses weak-value amplification to measure angular deflections of a target mirror while remaining insensitive to all translations of the target. We present demonstrated sensitivities and discuss practical implementation.

Frontiers in Optics•Jan 1, 2011•0 citations
We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 400+/-200 frad and the linear travel of a piezo actuator down to 14+/-7 fm.
We report on the use of an interferometric weak value technique to amplify small transverse deflections of an optical beam. Our techniques consists of coupling the beam’s transverse degrees of freedom to the which-path states of a Sagnac interferometer. The theory for the amplification, including signal to noise ratio considerations, is presented along with the experimental results which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and showed the signal to noise ratio to be amplified by a factor of 150.
Using the profound interferometric philosophy of weak-value amplification, we propose a simple, general, and robust polarization method for the amplification and quantification of small magnitudes of all possible polarization anisotropy effects in a single experimental embodiment. The approach is experimentally realized by introducing a weak coupling between the polarization degree of freedom of light and the path degree of freedom in a Mach-Zehnder interferometer in the presence of a weak anisotropy effect. Real and imaginary weak-value amplifications of different polarization anisotropy effects are manifested as characteristic changes in the relevant Stokes vector elements at the exit port of the interferometer, which follow orthogonal trajectories in the Poincar\'e sphere. The proof-of-concept experiment demonstrates that by using this scheme, one can faithfully extract and quantify an anisotropy parameter that is smaller than the typical sensitivity of measurement of a given Stokes parameter of a traditional polarimeter by a large weak-value amplification factor. This opens up the possibility of a sample measuring weak-value polarimeter for studying the rich variety of fundamental optical effects and for materials characterization and precision metrology.
We experimentally investigate the relative advantages of implementing weak-value-based metrology versus standard methods. While the techniques outlined herein apply more generally, we measure small optical beam deflections both using a Sagnac interferometer with a monitored dark port (the weak-value-based technique), and by focusing the entire beam to a split detector (the standard technique). By introducing controlled external transverse detector modulations and transverse beam deflection momentum modulations, we quantify the mitigation of these sources in the weak-value-based experiment versus the standard focusing experiment. The experiments are compared using a combination of deterministic and stochastic methods. In all cases, the weak-value technique performs the same or better than the standard technique by up to two orders of magnitude in precision for our parameters. We further measure the statistical efficiency of the weak-value-based technique. By postselecting on 11%1 of the photons, we obtain 9999%99 of the available Fisher information of the beam deflection parameter.
The amplification obtained using weak values is quantified through a detailed investigation of the signal-to-noise ratio for an optical beam-deflection measurement. We show that for a given deflection, input power and beam radius, the use of interferometric weak values allows one to obtain the optimum signal-to-noise ratio using a coherent beam. This method has the advantage of reduced technical noise and allows for the use of detectors with a low saturation intensity. We report on an experiment which improves the signal-to-noise ratio for a beam-deflection measurement by a factor of 54 when compared to a measurement using the same beam size and a quantum-limited detector.