A New Readout Electronic for Kinetic Inductance Detectors
Andrea Limonta, M. Zannoni, Gabriele Coppi, G. Conenna, Faouzi M. Boussaha, A. Tartari, M. Gervasi, F. Nati, Andrea Passerini, P. de Bernardis, A. Coppolecchia, G. D’Alessandro, S. Masi, A. Paiella, Marco Bersanelli, C. Franceschet, Elenia Manzan, ANIELLO MENNELLA
Abstract With this contribution we show the readout electronics for kinetic inductance detectors (KIDs) that we are developing based on commercial IQ transceivers from National Instruments and using a Virtex 5 class FPGA. It will be the readout electronics of the COSmic Monopole Observer (COSMO) experiment, a ground based cryogenic Martin–Puplett Interferometer searching for the cosmic microwave background spectral distortions. The readout electronics require a sampling rate in the range of tens of kHz, which is both due to a fast rotating mirror modulating the signal and the time constant of the COSMO KIDs. In this contribution we show the capabilities of our readout electronics using Niobium KIDs developed by Paris Observatory for our 5 K cryogenic system. In particular, we demonstrate the capability to detect 23 resonators from frequency sweeps and to readout the state of each resonator with a sampling rate of about 8 kHz. The readout is based on a finite-state machine where the first two states look for the resonances and generate the comb of tones, while the third one performs the acquisition of phase and amplitude of each detector in free running. Our electronics are based on commercial modules, which brings two key advantages: they can be acquired easily and it is relative simple to write and modify the firmware within the LabView environment in order to meet the needs of the experiment.
Abstract With this contribution we show the readout electronics for kinetic inductance detectors (KIDs) that we are developing based on commercial IQ transceivers from National Instruments and using a Virtex 5 class FPGA. It will be the readout electronics of the COSmic Monopole Observer (COSMO) experiment, a ground based cryogenic Martin–Puplett Interferometer searching for the cosmic microwave background spectral distortions. The readout electronics require a sampling rate in the range of tens of kHz, which is both due to a fast rotating mirror modulating the signal and the time constant of the COSMO KIDs. In this contribution we show the capabilities of our readout electronics using Niobium KIDs developed by Paris Observatory for our 5 K cryogenic system. In particular, we demonstrate the capability to detect 23 resonators from frequency sweeps and to readout the state of each resonator with a sampling rate of about 8 kHz. The readout is based on a finite-state machine where the first two states look for the resonances and generate the comb of tones, while the third one performs the acquisition of phase and amplitude of each detector in free running. Our electronics are based on commercial modules, which brings two key advantages: they can be acquired easily and it is relative simple to write and modify the firmware within the LabView environment in order to meet the needs of the experiment.
We present the development of a frequency-domain multiplexing readout of kinetic inductance detectors (KIDs) for pulse signals with a self-trigger system. The KIDs consist of an array of superconducting resonators that have different resonant frequencies individually, allowing us to read out multiple channels in the frequency domain with a single wire using a microwave-frequency comb. The energy deposited to the resonators break Cooper pairs, changing the kinetic inductance and, hence, the amplitude and the phase of the probing microwaves. For some applications such as X-ray detections, the deposited energy is detected as a pulse signal shaped by the time constants of the quasiparticle lifetime, the resonator quality factor, and the ballistic phonon lifetime in the substrate, ranging from microseconds to milliseconds. A readout system commonly used converts the frequency-domain data to the time-domain data. For the short pulse signals, the data rate may exceed the data transfer bandwidth, as the short time constant pulses require us to have a high sampling rate. In order to overcome this circumstance, we have developed a KID readout system that contains a self-trigger system to extract relevant signal data and reduces the total data rate with a commercial off-the-shelf FPGA board. We have demonstrated that the system can read out pulse signals of 15 resonators simultaneously with about 10 Hz event rate by irradiating α particles from 241 Am to the silicon substrate on whose surface aluminum KID resonators are formed.
A microwave kinetic inductance detector (MKID) is a superconducting pair-breaking detector used for astronomical observations in the sub-millimeter through visible range. Radiation is detected as a phase and amplitude signal proportional to the frequency shift of the device. In the case of arrays of MKIDs, the read-out is performed using the frequency division multiplexing technique. However, there is currently no commercial system or low-cost standard electronics available for this task. In this work, we take the first steps towards developing a low-cost readout system for MKIDs based on the Red Pitaya board. We have developed a firmware for the efficient generation of probe tones, and show figures of merit characterizing the performance of the readout in a hardware prototype. The design is flexible, letting us to adapt it to new frequencies and amplitudes requirements of the MKID arrays.
Kinetic inductance detectors (KIDs) are superconducting thin-film microresonators that are sensitive photon detectors. These detectors are a candidate for the next generation of experiments designed to measure the polarization of the cosmic microwave background (CMB). I discuss the basic theory needed to understand the response of a KID to light, focusing on the dynamics of the quasiparticle system. I derive an equation that describes the dynamics of the quasiparticle number, solve it in a simplified form not previously published, and show that it can describe the dynamic response of a detector. Magnetic flux vortices in a superconducting thin film can be a significant source of dissipation, and I demonstrate some techniques to prevent their formation. Based on the presented theory, I derive a corrected version of a widely-used equation for the quasiparticle recombination noise in a KID. I show that a KID consisting of a lumped-element resonator can be sensitive enough to be limited by photon noise, which is the fundamental limit for photometry, at a level of optical loading below levels in ground-based CMB experiments. Finally, I describe an ongoing project to develop multichroic KID pixels that are each sensitive to two linear polarization states in two spectral bands, intended for the next generation of CMB experiments. I show that a prototype 23-pixel array can detect millimeter-wave light, and present characterization measurements of the detectors.
Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
When we apply an AC current to a superconductor, the Cooper pairs oscillate and acquire kinetic inductance, that can be measured by inserting the superconductor in a LC circuit with high merit factor. Interactions in the superconductor can break the Cooper pairs,causing sizable variations in the kinetic inductance and, thus, the response of the LC circuit. This concept is at the basis of Kinetic Inductance Detectors (KIDs). The CALDER project aims to develope high sensitivity, cryogenic light detectors using KIDs in combination with a silicon absorber to cover, via phonon mediation, an area of several cm2 [1]. This contribution focuses on the development of a low-noise, digital and analogical,electronics for the sensor's readout and on the design and testing of a new geometry for the superconductive resonator to improve detector sensitivity.
The frequency comb generator is an essential component in the readout of superconducting detectors. This component is responsible for generating the resonant frequencies necessary to detect photon interaction with the detectors. This component however has not received the much needed attention in terms of readout systems optimization. Conventional implementations rely on either inverse fast Fourier transform (IFFT) engines, which scale poorly in power with increasing frequency resolution requirement but allow flexible tone updates, or lookup tables (LUTs), which demand large memory for high frequency resolution. Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors which have gained significant interest for cryogenic astrophysical instrumentation due to their high sensitivity, intrinsic multiplexing capability, and scalable fabrication. However, their simplified detector architecture shifts complexity to the readout electronics, making the development of compact, low-power frequency comb generators especially valuable. The design of the compact frequency comb generator targets applications involving MKIDs which typically detect photons in the submilliter bands. In this thesis, I present the design and hardware realization of a compact frequency comb generator. The design has been verified on an Field Programmable Gate Array (FPGA) using the Xilinx's RFSoC ZCU111 evaluation board. The architecture consumes less than 5% of FPGA resources and less than 5 Watts of power with the capability of handling multiple independent channels of the compact frequency comb generator on the evaluation board. These results demonstrate the potential of this approach to enable scalable, energy-efficient MKID readout systems for large-format detector arrays in next-generation cryogenic experiments.