Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1602.00442 · Journal of Low Temperature Physics

Calibration Scheme for Large Kinetic Inductance Detector Arrays Based on Readout Frequency Response

Laura Bisigello, S. J. C. Yates, Vignesh Murugesan, J. J. A. Baselmans, Andrey M. Baryshev

Published Feb 9, 2016• 14 citations
arXivHTMLPDF

Abstract

Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.

DOI
10.1007/s10909-016-1524-x

Related papers

A measurement method for responsivity of microwave kinetic inductance detector by changing power of readout microwaves

Hiroki Kutsuma, M. Hattori, Ryo Koyano +5 more

Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of the cutting-edge superconducting detectors. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase responses as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285 mK. We also confirm the consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.

arXiv:1907.03403•Applied Physics Letters•Jul 15, 2019•5 citations

Validity of analytical Microwave Kinetic Inductance Detector responsivity expressions

Elmore Vaal

Astrophysical photons with a sub-millimetre wavelength are of great value to research star and galaxy formation. Superconductors have a small energy gap with which these sub-millimetre photons can be measured. Superconductors can absorb photons so that quasiparticles are created, which will in turn change the complex conductivity: incoming photons change the electrical response of the superconductor. This principle can be used to realise a detector. This is done with the Microwave Kinetic Inductance Detectors (MKIDs) that consist of a superconducting film embedded in a resonant circuit, so that photons falling in will change the resonant frequency. This can be measured with a readout signal. To enhance the sensitivity of the MKID, we want to increase the responsivity of an MKID as much as possible.A previous study has proposed a figure of merit regarding the material properties of a superconductor to achieve a high responsivity. However, the readout frequency used is not included in this figure. The goal of this work is to extend the figure of merit so that the readout frequency of the MKID can be optimised for a higher responsivity.

•Jan 1, 2016•0 citations

Tunable responsivity and bandwidth in microwave kinetic inductance detectors via readout current nonlinearity

M. Rouble, Peter Day, Matt Dobbs +3 more

Microwave kinetic inductance detectors (MKIDs) are generally read out with microwave readout tones of high enough amplitude to adequately suppress the noise contribution of the first-stage amplifier. At high readout power, the detector's resonant frequency is altered as a result of the dependence of the kinetic inductance on the internally circulating microwave current. With the tone placed below the resonant frequency, the nonlinear frequency shift results in a positive feedback effect that can significantly enhance the responsivity of the detector, to both optical and microwave power. We report a factor of 10 enhancement in optical response by tuning the readout power and frequency to close to the resonator's bifurcation point. A corresponding decrease in the bandwidth of the resonator is observed under these conditions. We show that the strength of the feedback effect can be easily selected by adjusting the excitation, and provide a map of possible operational states to do so. Operation of MKIDs in this mode could be used to improve sensitivity when non-intrinsic noise sources are significant.

arXiv:2607.09178•Jul 10, 2026•0 citations

A method to measure superconducting transition temperature of microwave kinetic inductance detector by changing power of readout microwaves

Hiroki Kutsuma, Yoshinori Sueno, M. Hattori +5 more

A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited on the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we evaluate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.

arXiv:2005.08765•AIP Advances•Sep 1, 2020•2 citations

Design and Readout of Large MKID Arrays for Submillimeter Astronomy

James A. Schlaerth, Omid Noroozian, Nicole G. Czakon +16 more

Microwave Kinetic Inductance Detectors (MKIDs) are superconducting microresonators useful as detectors for sub/millimeter and far-infrared cameras, as well as instruments in optical and x-ray wavelengths. A probe sine wave at the resonance frequency can detect a change in frequency and microwave loss due to submillimeter optical load as a phase or amplitude change. These detectors may be coupled to light through on-chip, phased-array antennas. A single antenna may feed several detectors with different bandpasses defined by on-chip lumped-element filters. The resonators are easily frequency multiplexed by tuning the resonance frequencies, so hundreds of detectors can be read out while coupled to a single feedline. The deployment and operation of ground-based, background-limited detectors in close-packed arrays present significant challenges in both readout strategy and array design. The initial designs consisted of simple coplanar waveguide microwave resonators with aluminum absorptive sections. The first change has been to substitute the capacitive portion of the resonator with a large interdigitated capacitor (IDC) to reduce its noise contribution. While their low-noise characteristics have been demonstrated, these detectors had not yet been tested on array-scale devices. We present results from arrays of detectors designed for sub/millimeter imaging, tested for their optical response characteristics. In particular, we address challenges of microwave inter-resonator coupling, out-of-band resonator optical sensitivity, and noise reduction in the latest device designs. We show the results of stepped-impedance filters in preventing direct pickup of wide-band radiation, and new frequency spacing to limit crosstalk between resonators. We show direct comparison between olderdesign coplanar waveguide resonators and new IDC resonators under optical load, demonstrating the noise reduction and comparable responsivity. In addition, we show results of the probe signal readout power that maximizes signal-to-noise.

Softwaretechnik-Trends•Mar 1, 2010•0 citations

Kinetic inductance detectors for measuring the polarization of the cosmic microwave background

D. Flanigan

Kinetic inductance detectors (KIDs) are superconducting thin-film microresonators that are sensitive photon detectors. These detectors are a candidate for the next generation of experiments designed to measure the polarization of the cosmic microwave background (CMB). I discuss the basic theory needed to understand the response of a KID to light, focusing on the dynamics of the quasiparticle system. I derive an equation that describes the dynamics of the quasiparticle number, solve it in a simplified form not previously published, and show that it can describe the dynamic response of a detector. Magnetic flux vortices in a superconducting thin film can be a significant source of dissipation, and I demonstrate some techniques to prevent their formation. Based on the presented theory, I derive a corrected version of a widely-used equation for the quasiparticle recombination noise in a KID. I show that a KID consisting of a lumped-element resonator can be sensitive enough to be limited by photon noise, which is the fundamental limit for photometry, at a level of optical loading below levels in ground-based CMB experiments. Finally, I describe an ongoing project to develop multichroic KID pixels that are each sensitive to two linear polarization states in two spectral bands, intended for the next generation of CMB experiments. I show that a prototype 23-pixel array can detect millimeter-wave light, and present characterization measurements of the detectors.

•Jan 1, 2018•1 citation
Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of the cutting-edge superconducting detectors. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase responses as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285 mK. We also confirm the consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.
Astrophysical photons with a sub-millimetre wavelength are of great value to research star and galaxy formation. Superconductors have a small energy gap with which these sub-millimetre photons can be measured. Superconductors can absorb photons so that quasiparticles are created, which will in turn change the complex conductivity: incoming photons change the electrical response of the superconductor. This principle can be used to realise a detector. This is done with the Microwave Kinetic Inductance Detectors (MKIDs) that consist of a superconducting film embedded in a resonant circuit, so that photons falling in will change the resonant frequency. This can be measured with a readout signal. To enhance the sensitivity of the MKID, we want to increase the responsivity of an MKID as much as possible.A previous study has proposed a figure of merit regarding the material properties of a superconductor to achieve a high responsivity. However, the readout frequency used is not included in this figure. The goal of this work is to extend the figure of merit so that the readout frequency of the MKID can be optimised for a higher responsivity.
Microwave kinetic inductance detectors (MKIDs) are generally read out with microwave readout tones of high enough amplitude to adequately suppress the noise contribution of the first-stage amplifier. At high readout power, the detector's resonant frequency is altered as a result of the dependence of the kinetic inductance on the internally circulating microwave current. With the tone placed below the resonant frequency, the nonlinear frequency shift results in a positive feedback effect that can significantly enhance the responsivity of the detector, to both optical and microwave power. We report a factor of 10 enhancement in optical response by tuning the readout power and frequency to close to the resonator's bifurcation point. A corresponding decrease in the bandwidth of the resonator is observed under these conditions. We show that the strength of the feedback effect can be easily selected by adjusting the excitation, and provide a map of possible operational states to do so. Operation of MKIDs in this mode could be used to improve sensitivity when non-intrinsic noise sources are significant.
A microwave kinetic inductance detector (MKID) is a cutting-edge superconducting detector, and its principle is based on a superconducting resonator circuit. The superconducting transition temperature (Tc) of the MKID is an important parameter because various MKID characterization parameters depend on it. In this paper, we propose a method to measure the Tc of the MKID by changing the applied power of the readout microwaves. A small fraction of the readout power is deposited on the MKID, and the number of quasiparticles in the MKID increases with this power. Furthermore, the quasiparticle lifetime decreases with the number of quasiparticles. Therefore, we can measure the relation between the quasiparticle lifetime and the detector response by rapidly varying the readout power. From this relation, we evaluate the intrinsic quasiparticle lifetime. This lifetime is theoretically modeled by Tc, the physical temperature of the MKID device, and other known parameters. We obtain Tc by comparing the measured lifetime with that acquired using the theoretical model. Using an MKID fabricated with aluminum, we demonstrate this method at a 0.3 K operation. The results are consistent with those obtained by Tc measured by monitoring the transmittance of the readout microwaves with the variation in the device temperature. The method proposed in this paper is applicable to other types, such as a hybrid-type MKID.
Microwave Kinetic Inductance Detectors (MKIDs) are superconducting microresonators useful as detectors for sub/millimeter and far-infrared cameras, as well as instruments in optical and x-ray wavelengths. A probe sine wave at the resonance frequency can detect a change in frequency and microwave loss due to submillimeter optical load as a phase or amplitude change. These detectors may be coupled to light through on-chip, phased-array antennas. A single antenna may feed several detectors with different bandpasses defined by on-chip lumped-element filters. The resonators are easily frequency multiplexed by tuning the resonance frequencies, so hundreds of detectors can be read out while coupled to a single feedline. The deployment and operation of ground-based, background-limited detectors in close-packed arrays present significant challenges in both readout strategy and array design. The initial designs consisted of simple coplanar waveguide microwave resonators with aluminum absorptive sections. The first change has been to substitute the capacitive portion of the resonator with a large interdigitated capacitor (IDC) to reduce its noise contribution. While their low-noise characteristics have been demonstrated, these detectors had not yet been tested on array-scale devices. We present results from arrays of detectors designed for sub/millimeter imaging, tested for their optical response characteristics. In particular, we address challenges of microwave inter-resonator coupling, out-of-band resonator optical sensitivity, and noise reduction in the latest device designs. We show the results of stepped-impedance filters in preventing direct pickup of wide-band radiation, and new frequency spacing to limit crosstalk between resonators. We show direct comparison between olderdesign coplanar waveguide resonators and new IDC resonators under optical load, demonstrating the noise reduction and comparable responsivity. In addition, we show results of the probe signal readout power that maximizes signal-to-noise.
Kinetic inductance detectors (KIDs) are superconducting thin-film microresonators that are sensitive photon detectors. These detectors are a candidate for the next generation of experiments designed to measure the polarization of the cosmic microwave background (CMB). I discuss the basic theory needed to understand the response of a KID to light, focusing on the dynamics of the quasiparticle system. I derive an equation that describes the dynamics of the quasiparticle number, solve it in a simplified form not previously published, and show that it can describe the dynamic response of a detector. Magnetic flux vortices in a superconducting thin film can be a significant source of dissipation, and I demonstrate some techniques to prevent their formation. Based on the presented theory, I derive a corrected version of a widely-used equation for the quasiparticle recombination noise in a KID. I show that a KID consisting of a lumped-element resonator can be sensitive enough to be limited by photon noise, which is the fundamental limit for photometry, at a level of optical loading below levels in ground-based CMB experiments. Finally, I describe an ongoing project to develop multichroic KID pixels that are each sensitive to two linear polarization states in two spectral bands, intended for the next generation of CMB experiments. I show that a prototype 23-pixel array can detect millimeter-wave light, and present characterization measurements of the detectors.