Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Rabi oscillation of spin-polarized rubidium in the spin-exchange relaxation-free regime

Yaxiang Wang, Junjian Tang, Binquan Zhou, Ge Jin, Tao Shi, Sheng Zou, Bangcheng Han

Published Aug 31, 2022• 6 citations
Publisher

Abstract

The transient dynamics of atomic spins under oscillating and static magnetic fields have been studied in the spin-exchange relaxation-free (SERF) regime with a dual-beam configuration. The spin-relaxation rate can be accurately measured by detecting the transient response signal of the free induction decay (FID) process within several milliseconds. Leveraging this convenient method for measuring a large relaxation rate in a small cell volume, the dependence of the spin-relaxation rate on the probe intensity and ambient magnetic field was studied in the limit of low spin polarization. Moreover, by theoretical analysis of the dynamic evolution of the Rabi oscillation generated by a consecutive oscillating field and a small static magnetic field, we experimentally demonstrate that the amplitude of the Rabi oscillation is affected by the amplitude of the oscillating field in the SERF regime. According to the retrieved frequency of the FID signal and amplitude of relevant Rabi oscillation, the coil constants were 75.55 ± 0.78~nT/mA, 151.5 ± 0.9~nT/mA, and 116.6 ± 0.3~nT/mA along the x-, y-, and z-axes, respectively.

DOI
10.1364/oe.471475

Related papers

Transient dynamics of atomic spin in the spin-exchange-relaxation-free regime

Junjian Tang, Yan Yin, Yueyang Zhai +4 more

In this paper, we experimentally study transient dynamics of spin polarized atoms in the spin-exchange-relaxation-free (SERF) regime with a single-beam configuration. We pumped atoms with a weak detuning pumping beam, along with a sequence of magnetic field pulses orthogonal to the pumping beam were applied. The dynamics of atomic spin, which experiences Larmor precession under the perturbation of magnetic field, is detected by the transmitted pumping beam. Benefited from the long coherence time of atomic spin in the SERF regime, the dependence of precession frequency and decay rate, which is equal to the magnetic resonance linewidth of atomic spin, on magnetic fields is studied with the transient dynamics of atomic spin in the limit of low spin polarization. Moreover, we demonstrate that coil constants can be calibrated by analyzing the precession frequency of the transient dynamics of atomic spin. And the experimental results show that the coil constants are 114.25 ± 0.02 nT/mA and 114.12 ± 0.04 nT/mA in x- and y-axis, respectively. This method is particularly applicable to study the atomic spin dynamics and calibrate the coil constant in situ of a miniature single-beam SERF magnetometer.

Optics Express•Feb 17, 2021•24 citations

Determination of Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometer Using Transient Response

Junpeng Zhao, Ming Ding, Jixi Lu +5 more

A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.

IEEE Transactions on Instrumentation and Measurement•Apr 27, 2019•67 citations

Triaxial Coils In Situ Calibration Method Based on Measuring the Alternating Magnetic Field-Induced Dynamic Response of the SERF Magnetometer

Kun Wang, Danyue Ma, Siran Li +4 more

The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in situ calibration, we first studied the transient atomic dynamics of a dual-beam spin-exchange relaxation free (SERF) atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction-decay (FID) curves by alternately applying square wave signals to the${x}$-,${y}$-, and${z}$-axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x–y, y–z, and z–x, respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.

IEEE Sensors Journal•Jul 7, 2023•15 citations

An all-optical scalar and vector spin-exchange relaxation-free magnetometer employing on–off pump modulation

Alexander Gusarov, David Levron, Andrei Ben-Amar Baranga +2 more

It is demonstrated that a spin-exchange relaxation-free (SERF) atomic magnetometer can be used for scalar measurements with no additional hardware. Because of relaxation processes, an ensemble of alkali atoms needs a constant supply of polarized photons by a pump beam to maintain a polarized state. If the pump beam is shuttered off, the system decays to its equilibrium state. For a low enough relaxation rate and with a magnetic field present, the system will exhibit oscillations at its natural frequencies. In a SERF magnetometer, it happens at the Zeeman resonance frequency of the atoms (Larmor frequency). Thus, shuttering off the pump beam reveals oscillations at the Larmor frequency. From this frequency, one can deduce the scalar value of the applied magnetic field. As a result, all-optical scalar measurements can be performed. At the same time, either one or two vector components of the applied field can be measured by using one or two orthogonal probe beams, respectively. In a low-polarization SERF regime, the ground state can be well described by the Bloch equations for the electron spin polarization. By solving the time-dependent Bloch equations [neglecting the diffusion term and assuming that the nuclear slowing-down factor q(P) is constant], the oscillation frequency of the system is obtained. From this frequency, the scalar value of the applied magnetic field is derived. It is shown that applied fields down to 1 nT can be measured with a 0.1% relative uncertainty. Fields down to 50 pT can be measured with a 10% relative uncertainty. The time dependence acquired in the “off” periods is strongly correlated with the Zeeman sublevels population of the atomic ground state and reveals its spin dynamics.

Journal of Applied Physics•Mar 22, 2011•20 citations

Analysis of effects of magnetic field gradient on atomic spin polarization and relaxation in optically pumped atomic magnetometers

Xiujie Fang, Kai Wei, Yueyang Zhai +6 more

The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

Optics Express•Jan 14, 2022•61 citations

Fast extraction of the electron spin-relaxation rate in the SERF magnetometer from a transient response

Yanning Ma, Kaixuan Zhang, Yaoguo Wang +3 more

The magnitude of the electron spin-relaxation rate Rrel of the atomic ensemble directly affects the sensitivity of the spin-exchange relaxation-free (SERF) atomic magnetometer (AM). The rapid and in-situ characterization of Rrel is of great importance. In this work, a fast extraction method of Rrel is proposed with a measurement period shorten to 0.5 s, merely detecting the transient response of SERF AM to a transverse DC excitation magnetic field after switching off the pump beam. In contrast to the conventional methods based on the measurement of the magnetic resonance linewidth, this method circumvents the involvement of optical pumping rate, and enables monitoring Rrel under arbitrary polarization, which is expected to improve the authenticity of Rrel measurement in a more convenient way.

Optics Express•May 2, 2022•12 citations
The transient dynamics of atomic spins under oscillating and static magnetic fields have been studied in the spin-exchange relaxation-free (SERF) regime with a dual-beam configuration. The spin-relaxation rate can be accurately measured by detecting the transient response signal of the free induction decay (FID) process within several milliseconds. Leveraging this convenient method for measuring a large relaxation rate in a small cell volume, the dependence of the spin-relaxation rate on the probe intensity and ambient magnetic field was studied in the limit of low spin polarization. Moreover, by theoretical analysis of the dynamic evolution of the Rabi oscillation generated by a consecutive oscillating field and a small static magnetic field, we experimentally demonstrate that the amplitude of the Rabi oscillation is affected by the amplitude of the oscillating field in the SERF regime. According to the retrieved frequency of the FID signal and amplitude of relevant Rabi oscillation, the coil constants were 75.55 ± 0.78nT/mA, 151.5 ± 0.9nT/mA, and 116.6 ± 0.3~nT/mA along the x-, y-, and z-axes, respectively.
In this paper, we experimentally study transient dynamics of spin polarized atoms in the spin-exchange-relaxation-free (SERF) regime with a single-beam configuration. We pumped atoms with a weak detuning pumping beam, along with a sequence of magnetic field pulses orthogonal to the pumping beam were applied. The dynamics of atomic spin, which experiences Larmor precession under the perturbation of magnetic field, is detected by the transmitted pumping beam. Benefited from the long coherence time of atomic spin in the SERF regime, the dependence of precession frequency and decay rate, which is equal to the magnetic resonance linewidth of atomic spin, on magnetic fields is studied with the transient dynamics of atomic spin in the limit of low spin polarization. Moreover, we demonstrate that coil constants can be calibrated by analyzing the precession frequency of the transient dynamics of atomic spin. And the experimental results show that the coil constants are 114.25 ± 0.02 nT/mA and 114.12 ± 0.04 nT/mA in x- and y-axis, respectively. This method is particularly applicable to study the atomic spin dynamics and calibrate the coil constant in situ of a miniature single-beam SERF magnetometer.
A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.
The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in situ calibration, we first studied the transient atomic dynamics of a dual-beam spin-exchange relaxation free (SERF) atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction-decay (FID) curves by alternately applying square wave signals to thex{x}x-,y{y}y-, andz{z}z-axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x–y, y–z, and z–x, respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.
It is demonstrated that a spin-exchange relaxation-free (SERF) atomic magnetometer can be used for scalar measurements with no additional hardware. Because of relaxation processes, an ensemble of alkali atoms needs a constant supply of polarized photons by a pump beam to maintain a polarized state. If the pump beam is shuttered off, the system decays to its equilibrium state. For a low enough relaxation rate and with a magnetic field present, the system will exhibit oscillations at its natural frequencies. In a SERF magnetometer, it happens at the Zeeman resonance frequency of the atoms (Larmor frequency). Thus, shuttering off the pump beam reveals oscillations at the Larmor frequency. From this frequency, one can deduce the scalar value of the applied magnetic field. As a result, all-optical scalar measurements can be performed. At the same time, either one or two vector components of the applied field can be measured by using one or two orthogonal probe beams, respectively. In a low-polarization SERF regime, the ground state can be well described by the Bloch equations for the electron spin polarization. By solving the time-dependent Bloch equations [neglecting the diffusion term and assuming that the nuclear slowing-down factor q(P) is constant], the oscillation frequency of the system is obtained. From this frequency, the scalar value of the applied magnetic field is derived. It is shown that applied fields down to 1 nT can be measured with a 0.1% relative uncertainty. Fields down to 50 pT can be measured with a 10% relative uncertainty. The time dependence acquired in the “off” periods is strongly correlated with the Zeeman sublevels population of the atomic ground state and reveals its spin dynamics.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
The magnitude of the electron spin-relaxation rate Rrel of the atomic ensemble directly affects the sensitivity of the spin-exchange relaxation-free (SERF) atomic magnetometer (AM). The rapid and in-situ characterization of Rrel is of great importance. In this work, a fast extraction method of Rrel is proposed with a measurement period shorten to 0.5 s, merely detecting the transient response of SERF AM to a transverse DC excitation magnetic field after switching off the pump beam. In contrast to the conventional methods based on the measurement of the magnetic resonance linewidth, this method circumvents the involvement of optical pumping rate, and enables monitoring Rrel under arbitrary polarization, which is expected to improve the authenticity of Rrel measurement in a more convenient way.