Optics Express

Transient dynamics of atomic spin in the spin-exchange-relaxation-free regime

Junjian Tang, Yan Yin, Yueyang Zhai, Binquan Zhou, Bangcheng Han, Hongying Yang, Gang Liu

Published Feb 17, 2021• 24 citations
Publisher

Abstract

In this paper, we experimentally study transient dynamics of spin polarized atoms in the spin-exchange-relaxation-free (SERF) regime with a single-beam configuration. We pumped atoms with a weak detuning pumping beam, along with a sequence of magnetic field pulses orthogonal to the pumping beam were applied. The dynamics of atomic spin, which experiences Larmor precession under the perturbation of magnetic field, is detected by the transmitted pumping beam. Benefited from the long coherence time of atomic spin in the SERF regime, the dependence of precession frequency and decay rate, which is equal to the magnetic resonance linewidth of atomic spin, on magnetic fields is studied with the transient dynamics of atomic spin in the limit of low spin polarization. Moreover, we demonstrate that coil constants can be calibrated by analyzing the precession frequency of the transient dynamics of atomic spin. And the experimental results show that the coil constants are 114.25 ± 0.02 nT/mA and 114.12 ± 0.04 nT/mA in x- and y-axis, respectively. This method is particularly applicable to study the atomic spin dynamics and calibrate the coil constant in situ of a miniature single-beam SERF magnetometer.

DOI
10.1364/oe.418776

Related papers

Rabi oscillation of spin-polarized rubidium in the spin-exchange relaxation-free regime

Yaxiang Wang, Junjian Tang, Binquan Zhou +4 more

The transient dynamics of atomic spins under oscillating and static magnetic fields have been studied in the spin-exchange relaxation-free (SERF) regime with a dual-beam configuration. The spin-relaxation rate can be accurately measured by detecting the transient response signal of the free induction decay (FID) process within several milliseconds. Leveraging this convenient method for measuring a large relaxation rate in a small cell volume, the dependence of the spin-relaxation rate on the probe intensity and ambient magnetic field was studied in the limit of low spin polarization. Moreover, by theoretical analysis of the dynamic evolution of the Rabi oscillation generated by a consecutive oscillating field and a small static magnetic field, we experimentally demonstrate that the amplitude of the Rabi oscillation is affected by the amplitude of the oscillating field in the SERF regime. According to the retrieved frequency of the FID signal and amplitude of relevant Rabi oscillation, the coil constants were 75.55 ± 0.78~nT/mA, 151.5 ± 0.9~nT/mA, and 116.6 ± 0.3~nT/mA along the x-, y-, and z-axes, respectively.

Optics Express•Aug 31, 2022•6 citations

Determination of Spin Polarization in Spin-Exchange Relaxation-Free Atomic Magnetometer Using Transient Response

Junpeng Zhao, Ming Ding, Jixi Lu +5 more

A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.

IEEE Transactions on Instrumentation and Measurement•Apr 27, 2019•67 citations

Nonzero-Order Resonances in Single-Beam Spin-Exchange Relaxation-Free Magnetometers

Kun Wang, Kaixuan Zhang, Nuozhou Xu +3 more

Zero-field optically pumped magnetometers operating in the spin-exchange relaxation-free (SERF) regime have been extensively studied, and usually depend on zeroth-order parametric resonance to measure the magnetic field. However, the studies conducted on this topic lack thorough analyses and in-depth discussion of nonzero-order magnetic resonances in single-beam SERF magnetometers. In this paper, we analyzed the nonzero-order resonance, especially the first-order resonance, based on a single-beam SERF magnetometer, and discussed its various applications. A comprehensive theoretical analysis and experiments were conducted with respect to multiple functions, including nonzero finite magnetic field measurements, spin polarization measurement, and in situ coil constant calibration. The results showed that first-order resonance can be utilized for nonzerofinite magnetic field measurements, and the spin polarization of alkali-metal atoms can be determined by measuring the slowing-down factor using the resonance condition. Furthermore, acquiring the first-order resonance point at an equivalent zero pump light power through fitting offers an approach for quick and precise in situ coil constant calibration. This study contributes to the applications of SERF magnetometers in nonzero finite magnetic fields.

Photonics•Apr 15, 2023•2 citations

Triaxial Coils In Situ Calibration Method Based on Measuring the Alternating Magnetic Field-Induced Dynamic Response of the SERF Magnetometer

Kun Wang, Danyue Ma, Siran Li +4 more

The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in situ calibration, we first studied the transient atomic dynamics of a dual-beam spin-exchange relaxation free (SERF) atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction-decay (FID) curves by alternately applying square wave signals to the${x}$-,${y}$-, and${z}$-axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x–y, y–z, and z–x, respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.

IEEE Sensors Journal•Jul 7, 2023•15 citations

An all-optical scalar and vector spin-exchange relaxation-free magnetometer employing on–off pump modulation

Alexander Gusarov, David Levron, Andrei Ben-Amar Baranga +2 more

It is demonstrated that a spin-exchange relaxation-free (SERF) atomic magnetometer can be used for scalar measurements with no additional hardware. Because of relaxation processes, an ensemble of alkali atoms needs a constant supply of polarized photons by a pump beam to maintain a polarized state. If the pump beam is shuttered off, the system decays to its equilibrium state. For a low enough relaxation rate and with a magnetic field present, the system will exhibit oscillations at its natural frequencies. In a SERF magnetometer, it happens at the Zeeman resonance frequency of the atoms (Larmor frequency). Thus, shuttering off the pump beam reveals oscillations at the Larmor frequency. From this frequency, one can deduce the scalar value of the applied magnetic field. As a result, all-optical scalar measurements can be performed. At the same time, either one or two vector components of the applied field can be measured by using one or two orthogonal probe beams, respectively. In a low-polarization SERF regime, the ground state can be well described by the Bloch equations for the electron spin polarization. By solving the time-dependent Bloch equations [neglecting the diffusion term and assuming that the nuclear slowing-down factor q(P) is constant], the oscillation frequency of the system is obtained. From this frequency, the scalar value of the applied magnetic field is derived. It is shown that applied fields down to 1 nT can be measured with a 0.1% relative uncertainty. Fields down to 50 pT can be measured with a 10% relative uncertainty. The time dependence acquired in the “off” periods is strongly correlated with the Zeeman sublevels population of the atomic ground state and reveals its spin dynamics.

Journal of Applied Physics•Mar 22, 2011•20 citations

Measuring Spin Polarization of a Spin-Exchange Relaxation-Free Atomic Magnetometer at Extremely Large Optical Depths

Yanning Ma, Jixi Lu, Ke Yang +5 more

This paper presents a method for measuring the spin polarization of spin-exchange relaxation-free (SERF) atomic magnetometers at extremely large optical depths. Owing to the slowing-down effect, the spin polarization can be extracted by measuring the slowing-down factor extracted from the precession frequency. However, this technique is limited by a significant error in the regime of extremely large optical depths, where the pump beam intensity for achieving the optimized spin polarization of alkali atoms is significantly increased. We observed that the instantaneous precession frequency measured in the regime where the spin-exchange rate is not much larger than the Larmor frequency was no longer a constant but varied with the pump beam intensity. Thus, a method for measuring spin polarization based on the ratio of the precession frequency to the measured instantaneous precession frequency is proposed. Based on the proposed method, the spin polarization at a temperature of 473K and optical depth of 64 is measured. The measurement results were accordant with theoretical analysis. The expanded uncertainties of the experimental results varied between 1.8% and 9.6%. The proposed method is also applicable to other atomic devices operated in the SERF regime with extremely large optical depths, such as co-magnetometers and atomic spin gyroscopes.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•8 citations
In this paper, we experimentally study transient dynamics of spin polarized atoms in the spin-exchange-relaxation-free (SERF) regime with a single-beam configuration. We pumped atoms with a weak detuning pumping beam, along with a sequence of magnetic field pulses orthogonal to the pumping beam were applied. The dynamics of atomic spin, which experiences Larmor precession under the perturbation of magnetic field, is detected by the transmitted pumping beam. Benefited from the long coherence time of atomic spin in the SERF regime, the dependence of precession frequency and decay rate, which is equal to the magnetic resonance linewidth of atomic spin, on magnetic fields is studied with the transient dynamics of atomic spin in the limit of low spin polarization. Moreover, we demonstrate that coil constants can be calibrated by analyzing the precession frequency of the transient dynamics of atomic spin. And the experimental results show that the coil constants are 114.25 ± 0.02 nT/mA and 114.12 ± 0.04 nT/mA in x- and y-axis, respectively. This method is particularly applicable to study the atomic spin dynamics and calibrate the coil constant in situ of a miniature single-beam SERF magnetometer.
The transient dynamics of atomic spins under oscillating and static magnetic fields have been studied in the spin-exchange relaxation-free (SERF) regime with a dual-beam configuration. The spin-relaxation rate can be accurately measured by detecting the transient response signal of the free induction decay (FID) process within several milliseconds. Leveraging this convenient method for measuring a large relaxation rate in a small cell volume, the dependence of the spin-relaxation rate on the probe intensity and ambient magnetic field was studied in the limit of low spin polarization. Moreover, by theoretical analysis of the dynamic evolution of the Rabi oscillation generated by a consecutive oscillating field and a small static magnetic field, we experimentally demonstrate that the amplitude of the Rabi oscillation is affected by the amplitude of the oscillating field in the SERF regime. According to the retrieved frequency of the FID signal and amplitude of relevant Rabi oscillation, the coil constants were 75.55 ± 0.78~nT/mA, 151.5 ± 0.9~nT/mA, and 116.6 ± 0.3~nT/mA along the x-, y-, and z-axes, respectively.
A novel method to determine the spin polarization and its distribution for a spin-exchange relaxation-free (SERF) atomic magnetometer are proposed in this paper. The Larmor precession frequency is measured using the fast Fourier transform (FFT) analysis result of the transient response of the magnetometer under the excitation of a series of the step-changed magnetic field. The spin polarization is extracted from the slow-down factor of the precession frequency. The variation of the spin polarization with different pump light intensities and the distribution of the spin polarization along the direction of the pump light are analyzed, and the experimental results are well consistent with the theoretical predictions. The expanded uncertainties of the experimental results vary from 2% to 11% with the increase of the spin polarization and the reason for this variation is analyzed. The advantage of this method is that it allows the accurate measurement of the spin polarization in the pump beam direction within the SERF regime operating state, and it is unaffected by the large optical depth of the vapor cell.
Zero-field optically pumped magnetometers operating in the spin-exchange relaxation-free (SERF) regime have been extensively studied, and usually depend on zeroth-order parametric resonance to measure the magnetic field. However, the studies conducted on this topic lack thorough analyses and in-depth discussion of nonzero-order magnetic resonances in single-beam SERF magnetometers. In this paper, we analyzed the nonzero-order resonance, especially the first-order resonance, based on a single-beam SERF magnetometer, and discussed its various applications. A comprehensive theoretical analysis and experiments were conducted with respect to multiple functions, including nonzero finite magnetic field measurements, spin polarization measurement, and in situ coil constant calibration. The results showed that first-order resonance can be utilized for nonzerofinite magnetic field measurements, and the spin polarization of alkali-metal atoms can be determined by measuring the slowing-down factor using the resonance condition. Furthermore, acquiring the first-order resonance point at an equivalent zero pump light power through fitting offers an approach for quick and precise in situ coil constant calibration. This study contributes to the applications of SERF magnetometers in nonzero finite magnetic fields.
The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in situ calibration, we first studied the transient atomic dynamics of a dual-beam spin-exchange relaxation free (SERF) atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction-decay (FID) curves by alternately applying square wave signals to thex{x}x-,y{y}y-, andz{z}z-axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x–y, y–z, and z–x, respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.
It is demonstrated that a spin-exchange relaxation-free (SERF) atomic magnetometer can be used for scalar measurements with no additional hardware. Because of relaxation processes, an ensemble of alkali atoms needs a constant supply of polarized photons by a pump beam to maintain a polarized state. If the pump beam is shuttered off, the system decays to its equilibrium state. For a low enough relaxation rate and with a magnetic field present, the system will exhibit oscillations at its natural frequencies. In a SERF magnetometer, it happens at the Zeeman resonance frequency of the atoms (Larmor frequency). Thus, shuttering off the pump beam reveals oscillations at the Larmor frequency. From this frequency, one can deduce the scalar value of the applied magnetic field. As a result, all-optical scalar measurements can be performed. At the same time, either one or two vector components of the applied field can be measured by using one or two orthogonal probe beams, respectively. In a low-polarization SERF regime, the ground state can be well described by the Bloch equations for the electron spin polarization. By solving the time-dependent Bloch equations [neglecting the diffusion term and assuming that the nuclear slowing-down factor q(P) is constant], the oscillation frequency of the system is obtained. From this frequency, the scalar value of the applied magnetic field is derived. It is shown that applied fields down to 1 nT can be measured with a 0.1% relative uncertainty. Fields down to 50 pT can be measured with a 10% relative uncertainty. The time dependence acquired in the “off” periods is strongly correlated with the Zeeman sublevels population of the atomic ground state and reveals its spin dynamics.
This paper presents a method for measuring the spin polarization of spin-exchange relaxation-free (SERF) atomic magnetometers at extremely large optical depths. Owing to the slowing-down effect, the spin polarization can be extracted by measuring the slowing-down factor extracted from the precession frequency. However, this technique is limited by a significant error in the regime of extremely large optical depths, where the pump beam intensity for achieving the optimized spin polarization of alkali atoms is significantly increased. We observed that the instantaneous precession frequency measured in the regime where the spin-exchange rate is not much larger than the Larmor frequency was no longer a constant but varied with the pump beam intensity. Thus, a method for measuring spin polarization based on the ratio of the precession frequency to the measured instantaneous precession frequency is proposed. Based on the proposed method, the spin polarization at a temperature of 473K and optical depth of 64 is measured. The measurement results were accordant with theoretical analysis. The expanded uncertainties of the experimental results varied between 1.8% and 9.6%. The proposed method is also applicable to other atomic devices operated in the SERF regime with extremely large optical depths, such as co-magnetometers and atomic spin gyroscopes.