Precision measurement of the density shift caused by the interaction among neutral atoms trapped in an optical lattice has important applications in the study of multi-body interaction and the realization of high-performance optical lattice clocks. The common methods of measuring the density are the self-comparison technique and frequency comparison between two optical lattice clocks. Both methods are based on the identical density shift coefficient and should interrelatedly operate the clock at high- and low-density state, respectively. The precision of self-comparison method is limited by the Dick effect. The synchronous frequency comparison between two optical lattice clocks can realize the precision beyond the Dick limit. However, both methods can only obtain the average density shift and ignore the fact that the magnitude of the density shift is different over the lattice sites as inhomogeneous density distribution in the lattice. In this paper, the synchronous frequency comparison technique based on in situ imaging is used to accurately measure the density shift coefficient of optical lattice clock. Atoms in the optical lattice are simultaneously and independently excited by the same clock laser beam, and the clock transition probability of 11 uncorrelated regions of the optical lattice is simultaneously detected by in situ imaging. Thus, the clock laser noise, which is the root cause of the Dick effect, is common-mode rejected as the frequency difference between uncorrelated regions is measured by the clock transition spectrum. Beyond the Dick-noise-limited stability, the stability of synchronous frequency comparison between uncorrelated regions is consistent with the limit resulting from the atom detection noise. Between the center and margin of the lattice, the differential shifts of the black-body radiation shift, lattice AC Stark shift, probe Stark shift, DC Stark shift, and quadratic Zeeman shift are all below 5 × 10–6 Hz, which is three orders of magnitude smaller than the density shift and can be ignored in this experiment. Benefitting from the inhomogeneous distribution of atom number and negligible external field gradient in the optical lattice, the compared frequency shift between uncorrelated regions indicates the density shift. By measuring the relationship between the density shift and atom difference, the density shift coefficient is determined as –0.101(3) Hz/atom/site (with a measurement time of 103 s), and the fractional measurement uncertainty of the mean density shift of our system is 1.5 × 10–17.
Precision measurement of the density shift caused by the interaction among neutral atoms trapped in an optical lattice has important applications in the study of multi-body interaction and the realization of high-performance optical lattice clocks. The common methods of measuring the density are the self-comparison technique and frequency comparison between two optical lattice clocks. Both methods are based on the identical density shift coefficient and should interrelatedly operate the clock at high- and low-density state, respectively. The precision of self-comparison method is limited by the Dick effect. The synchronous frequency comparison between two optical lattice clocks can realize the precision beyond the Dick limit. However, both methods can only obtain the average density shift and ignore the fact that the magnitude of the density shift is different over the lattice sites as inhomogeneous density distribution in the lattice. In this paper, the synchronous frequency comparison technique based on in situ imaging is used to accurately measure the density shift coefficient of optical lattice clock. Atoms in the optical lattice are simultaneously and independently excited by the same clock laser beam, and the clock transition probability of 11 uncorrelated regions of the optical lattice is simultaneously detected by in situ imaging. Thus, the clock laser noise, which is the root cause of the Dick effect, is common-mode rejected as the frequency difference between uncorrelated regions is measured by the clock transition spectrum. Beyond the Dick-noise-limited stability, the stability of synchronous frequency comparison between uncorrelated regions is consistent with the limit resulting from the atom detection noise. Between the center and margin of the lattice, the differential shifts of the black-body radiation shift, lattice AC Stark shift, probe Stark shift, DC Stark shift, and quadratic Zeeman shift are all below 5 × 10–6 Hz, which is three orders of magnitude smaller than the density shift and can be ignored in this experiment. Benefitting from the inhomogeneous distribution of atom number and negligible external field gradient in the optical lattice, the compared frequency shift between uncorrelated regions indicates the density shift. By measuring the relationship between the density shift and atom difference, the density shift coefficient is determined as –0.101(3) Hz/atom/site (with a measurement time of 103 s), and the fractional measurement uncertainty of the mean density shift of our system is 1.5 × 10–17.
In this paper, we demonstrate in situ synchronous frequency comparison between distinct regions in a one-dimensional optical lattice. The synchronous comparison instability is well below the Dick limit and agrees with the limit induced by atomic detection noise. The absolute atom number is extracted from the synchronous comparison instability with an uncertainty below 3%. Surpassing the performance of absorption imaging, this method provides a way to directly and precisely determine the absolute atom number from detection noise. Taking advantage of the inhomogeneous density distribution over the whole lattice, the density shift can also be conveniently measured by this synchronous frequency comparison method. Inconsistent with the expectation of the linear relationship between density shift and atom number difference, nonlinearity is observed, indicating that the assumption of an identical density shift coefficient over the whole lattice is not always safe.
Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.
We present a synchronous frequency comparison method based on one cold-atom ensemble by using the dual-excitation spectrum technique, which can simultaneously detect the probabilities of two different clock transitions. We experimentally verify this synchronous frequency comparison method between |mF|=9/2 and |mF|=7/2 in a one-dimensional 87Sr optical lattice clock and the comparison instability is well below the Dick limit. We also extend the dual-excitation spectrum method to shorten the clock feedback cycle by a half in optical lattice clocks and experimentally demonstrate that the interleaved self-comparison instability is 1.4 times lower than that of the traditional operation method.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.