Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Determining the atom number from detection noise in a one-dimensional optical lattice clock

Xiaotong Lu, Jingjing Xia, Benquan Lu, Yebing Wang, Tao Wang, Hong Chang

Published Apr 11, 2022• 4 citations
Publisher

Abstract

In this paper, we demonstrate in situ synchronous frequency comparison between distinct regions in a one-dimensional optical lattice. The synchronous comparison instability is well below the Dick limit and agrees with the limit induced by atomic detection noise. The absolute atom number is extracted from the synchronous comparison instability with an uncertainty below 3%. Surpassing the performance of absorption imaging, this method provides a way to directly and precisely determine the absolute atom number from detection noise. Taking advantage of the inhomogeneous density distribution over the whole lattice, the density shift can also be conveniently measured by this synchronous frequency comparison method. Inconsistent with the expectation of the linear relationship between density shift and atom number difference, nonlinearity is observed, indicating that the assumption of an identical density shift coefficient over the whole lattice is not always safe.

DOI
10.1063/5.0085166

Related papers

Density shift measurement and synchronous frequency comparison based on in situ imaging technique

Xiaohua Hu, Xiaotong Lu, Xiao-Fei Zhang +1 more

Precision measurement of the density shift caused by the interaction among neutral atoms trapped in an optical lattice has important applications in the study of multi-body interaction and the realization of high-performance optical lattice clocks. The common methods of measuring the density are the self-comparison technique and frequency comparison between two optical lattice clocks. Both methods are based on the identical density shift coefficient and should interrelatedly operate the clock at high- and low-density state, respectively. The precision of self-comparison method is limited by the Dick effect. The synchronous frequency comparison between two optical lattice clocks can realize the precision beyond the Dick limit. However, both methods can only obtain the average density shift and ignore the fact that the magnitude of the density shift is different over the lattice sites as inhomogeneous density distribution in the lattice. In this paper, the synchronous frequency comparison technique based on in situ imaging is used to accurately measure the density shift coefficient of optical lattice clock. Atoms in the optical lattice are simultaneously and independently excited by the same clock laser beam, and the clock transition probability of 11 uncorrelated regions of the optical lattice is simultaneously detected by in situ imaging. Thus, the clock laser noise, which is the root cause of the Dick effect, is common-mode rejected as the frequency difference between uncorrelated regions is measured by the clock transition spectrum. Beyond the Dick-noise-limited stability, the stability of synchronous frequency comparison between uncorrelated regions is consistent with the limit resulting from the atom detection noise. Between the center and margin of the lattice, the differential shifts of the black-body radiation shift, lattice AC Stark shift, probe Stark shift, DC Stark shift, and quadratic Zeeman shift are all below 5 × 10–6 Hz, which is three orders of magnitude smaller than the density shift and can be ignored in this experiment. Benefitting from the inhomogeneous distribution of atom number and negligible external field gradient in the optical lattice, the compared frequency shift between uncorrelated regions indicates the density shift. By measuring the relationship between the density shift and atom difference, the density shift coefficient is determined as –0.101(3) Hz/atom/site (with a measurement time of 103 s), and the fractional measurement uncertainty of the mean density shift of our system is 1.5 × 10–17.

Acta Physica Sinica•Jan 1, 2022•0 citations

Synchronous frequency comparison beyond the Dick limit based on dual-excitation spectrum in an optical lattice clock

Xiaotong Lu, Chihua Zhou, Ting Li +2 more

We present a synchronous frequency comparison method based on one cold-atom ensemble by using the dual-excitation spectrum technique, which can simultaneously detect the probabilities of two different clock transitions. We experimentally verify this synchronous frequency comparison method between |mF|=9/2 and |mF|=7/2 in a one-dimensional 87Sr optical lattice clock and the comparison instability is well below the Dick limit. We also extend the dual-excitation spectrum method to shorten the clock feedback cycle by a half in optical lattice clocks and experimentally demonstrate that the interleaved self-comparison instability is 1.4 times lower than that of the traditional operation method.

Applied Physics Letters•Dec 7, 2020•8 citations

Stability analysis in an optical lattice clock using the four-path measurement

Xiaotong Lu, Feng Guo, Jingjing Xia +3 more

In this paper, we propose a method for identifying the contribution of various sources of noise to the instability of an optical lattice clock. These sources include Dick noise, quantum projection noise, shot noise, and technical noise. By measuring the clock instability at four different sets of parameters, we can determine the frequency fluctuations due to each type of noise separately. Furthermore, we can accurately extract the absolute number of atoms, the photon number detected per atom by the photoelectric detector, and the root mean square fluctuations of the atom number. We demonstrate the effectiveness of our approach through numerical simulations, showcasing the ability to determine these parameters with an uncertainty of less than 10%. Specifically, a remarkable uncertainty of 1% can be achieved when determining the atom number.

Physical Review A•Feb 13, 2024•1 citation

Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems

Qi Gao, Min Zhou, Chengyin Han +12 more

Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.

Scientific Reports•May 16, 2018•42 citations

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•204 citations

Synchronous frequency comparison of optical lattice clocks to approach the quantum limit

Hidetoshi Katori, T. Takano, Masao Takamoto

We demonstrate a synchronous frequency comparison of two optical lattice clocks operated using87Sr and88Sr atoms, whose Allan standard deviation achieved 1 × 10-17in an averaging time of 1,600 s by cancelling out the Dick effect to approach the QPN limit. The scheme manifests an advantage of using a large number N ≈ 2,000 of atoms in optical clocks and paves the way to investigate clocks' inherent uncertainties and relativistic geodesy on a time scale of tens of minutes.

URSI General Assembly and Scientific Symposium•Aug 1, 2011•0 citations
In this paper, we demonstrate in situ synchronous frequency comparison between distinct regions in a one-dimensional optical lattice. The synchronous comparison instability is well below the Dick limit and agrees with the limit induced by atomic detection noise. The absolute atom number is extracted from the synchronous comparison instability with an uncertainty below 3%. Surpassing the performance of absorption imaging, this method provides a way to directly and precisely determine the absolute atom number from detection noise. Taking advantage of the inhomogeneous density distribution over the whole lattice, the density shift can also be conveniently measured by this synchronous frequency comparison method. Inconsistent with the expectation of the linear relationship between density shift and atom number difference, nonlinearity is observed, indicating that the assumption of an identical density shift coefficient over the whole lattice is not always safe.
Precision measurement of the density shift caused by the interaction among neutral atoms trapped in an optical lattice has important applications in the study of multi-body interaction and the realization of high-performance optical lattice clocks. The common methods of measuring the density are the self-comparison technique and frequency comparison between two optical lattice clocks. Both methods are based on the identical density shift coefficient and should interrelatedly operate the clock at high- and low-density state, respectively. The precision of self-comparison method is limited by the Dick effect. The synchronous frequency comparison between two optical lattice clocks can realize the precision beyond the Dick limit. However, both methods can only obtain the average density shift and ignore the fact that the magnitude of the density shift is different over the lattice sites as inhomogeneous density distribution in the lattice. In this paper, the synchronous frequency comparison technique based on in situ imaging is used to accurately measure the density shift coefficient of optical lattice clock. Atoms in the optical lattice are simultaneously and independently excited by the same clock laser beam, and the clock transition probability of 11 uncorrelated regions of the optical lattice is simultaneously detected by in situ imaging. Thus, the clock laser noise, which is the root cause of the Dick effect, is common-mode rejected as the frequency difference between uncorrelated regions is measured by the clock transition spectrum. Beyond the Dick-noise-limited stability, the stability of synchronous frequency comparison between uncorrelated regions is consistent with the limit resulting from the atom detection noise. Between the center and margin of the lattice, the differential shifts of the black-body radiation shift, lattice AC Stark shift, probe Stark shift, DC Stark shift, and quadratic Zeeman shift are all below 5 × 10–6 Hz, which is three orders of magnitude smaller than the density shift and can be ignored in this experiment. Benefitting from the inhomogeneous distribution of atom number and negligible external field gradient in the optical lattice, the compared frequency shift between uncorrelated regions indicates the density shift. By measuring the relationship between the density shift and atom difference, the density shift coefficient is determined as –0.101(3) Hz/atom/site (with a measurement time of 103 s), and the fractional measurement uncertainty of the mean density shift of our system is 1.5 × 10–17.
We present a synchronous frequency comparison method based on one cold-atom ensemble by using the dual-excitation spectrum technique, which can simultaneously detect the probabilities of two different clock transitions. We experimentally verify this synchronous frequency comparison method between |mF|=9/2 and |mF|=7/2 in a one-dimensional 87Sr optical lattice clock and the comparison instability is well below the Dick limit. We also extend the dual-excitation spectrum method to shorten the clock feedback cycle by a half in optical lattice clocks and experimentally demonstrate that the interleaved self-comparison instability is 1.4 times lower than that of the traditional operation method.
In this paper, we propose a method for identifying the contribution of various sources of noise to the instability of an optical lattice clock. These sources include Dick noise, quantum projection noise, shot noise, and technical noise. By measuring the clock instability at four different sets of parameters, we can determine the frequency fluctuations due to each type of noise separately. Furthermore, we can accurately extract the absolute number of atoms, the photon number detected per atom by the photoelectric detector, and the root mean square fluctuations of the atom number. We demonstrate the effectiveness of our approach through numerical simulations, showcasing the ability to determine these parameters with an uncertainty of less than 10%. Specifically, a remarkable uncertainty of 1% can be achieved when determining the atom number.
Abstract Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.