Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Synchronous frequency comparison beyond the Dick limit based on dual-excitation spectrum in an optical lattice clock

Xiaotong Lu, Chihua Zhou, Ting Li, Yebing Wang, Hong Chang

Published Dec 7, 2020• 8 citations
Publisher

Abstract

We present a synchronous frequency comparison method based on one cold-atom ensemble by using the dual-excitation spectrum technique, which can simultaneously detect the probabilities of two different clock transitions. We experimentally verify this synchronous frequency comparison method between |mF|=9/2 and |mF|=7/2 in a one-dimensional 87Sr optical lattice clock and the comparison instability is well below the Dick limit. We also extend the dual-excitation spectrum method to shorten the clock feedback cycle by a half in optical lattice clocks and experimentally demonstrate that the interleaved self-comparison instability is 1.4 times lower than that of the traditional operation method.

DOI
10.1063/5.0025097

Related papers

Determining the atom number from detection noise in a one-dimensional optical lattice clock

Xiaotong Lu, Jingjing Xia, Benquan Lu +3 more

In this paper, we demonstrate in situ synchronous frequency comparison between distinct regions in a one-dimensional optical lattice. The synchronous comparison instability is well below the Dick limit and agrees with the limit induced by atomic detection noise. The absolute atom number is extracted from the synchronous comparison instability with an uncertainty below 3%. Surpassing the performance of absorption imaging, this method provides a way to directly and precisely determine the absolute atom number from detection noise. Taking advantage of the inhomogeneous density distribution over the whole lattice, the density shift can also be conveniently measured by this synchronous frequency comparison method. Inconsistent with the expectation of the linear relationship between density shift and atom number difference, nonlinearity is observed, indicating that the assumption of an identical density shift coefficient over the whole lattice is not always safe.

Applied Physics Letters•Apr 11, 2022•4 citations

Frequency comparison of optical lattice clocks

Masao Takamoto, T. Takano, Hidetoshi Katori

We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations

Systematic evaluation of a 171Yb optical clock by synchronous comparison between two lattice systems

Qi Gao, Min Zhou, Chengyin Han +12 more

Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.

Scientific Reports•May 22, 2018•46 citations

Synchronous frequency comparison of optical lattice clocks to approach the quantum limit

Hidetoshi Katori, T. Takano, Masao Takamoto

We demonstrate a synchronous frequency comparison of two optical lattice clocks operated using87Sr and88Sr atoms, whose Allan standard deviation achieved 1 × 10-17in an averaging time of 1,600 s by cancelling out the Dick effect to approach the QPN limit. The scheme manifests an advantage of using a large number N ≈ 2,000 of atoms in optical clocks and paves the way to investigate clocks' inherent uncertainties and relativistic geodesy on a time scale of tens of minutes.

URSI General Assembly and Scientific Symposium•Aug 1, 2011•0 citations

Synchronous Comparison of Two Thulium Optical Clocks

Artem A. Golovizin, D. Mishin, Daniil I. Provorchenko +2 more

The experimental comparison of two thulium optical lattice clocks in a time interval of up to one hour has been carried out. The synchronous comparison of a clock transition in two independent atomic ensembles using a single ultrastable laser has allowed us to eliminate fluctuations of the laser frequency from the measured frequency difference and to reach a relative measurement error of 10–16 after 500-s averaging, which corresponds to a relative instability of $$2 \times {{10}^{{ - 15}}}{\text{/}}\sqrt \tau $$ . The successful demonstration of the long-term operation of two systems using the synchronous comparison of clock transitions opens the possibility of studying systematic shifts in thulium optical clocks with an uncertainty of 10–17.

arXiv:2407.04139•Journal of Experimental and Theoretical Physics Letters•May 1, 2024•5 citations

通过减小碰撞导致的退相干和谱线增宽提高光晶格钟稳定度

Chihua Zhou, Xiaotong Lu, 郭峰 Guo Feng +3 more

Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.

Acta Optica Sinica•Jan 1, 2023•0 citations
We present a synchronous frequency comparison method based on one cold-atom ensemble by using the dual-excitation spectrum technique, which can simultaneously detect the probabilities of two different clock transitions. We experimentally verify this synchronous frequency comparison method between |mF|=9/2 and |mF|=7/2 in a one-dimensional 87Sr optical lattice clock and the comparison instability is well below the Dick limit. We also extend the dual-excitation spectrum method to shorten the clock feedback cycle by a half in optical lattice clocks and experimentally demonstrate that the interleaved self-comparison instability is 1.4 times lower than that of the traditional operation method.
In this paper, we demonstrate in situ synchronous frequency comparison between distinct regions in a one-dimensional optical lattice. The synchronous comparison instability is well below the Dick limit and agrees with the limit induced by atomic detection noise. The absolute atom number is extracted from the synchronous comparison instability with an uncertainty below 3%. Surpassing the performance of absorption imaging, this method provides a way to directly and precisely determine the absolute atom number from detection noise. Taking advantage of the inhomogeneous density distribution over the whole lattice, the density shift can also be conveniently measured by this synchronous frequency comparison method. Inconsistent with the expectation of the linear relationship between density shift and atom number difference, nonlinearity is observed, indicating that the assumption of an identical density shift coefficient over the whole lattice is not always safe.
We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.
Optical clocks are the most precise measurement devices. Here we experimentally characterize one such clock based on the 1S0-3P0 transition of neutral 171Yb atoms confined in an optical lattice. Given that the systematic evaluation using an interleaved stabilization scheme is unable to avoid noise from the clock laser, synchronous comparisons against a second 171Yb lattice system were implemented to accelerate the evaluation. The fractional instability of one clock falls below 4 × 10−17 after an averaging over a time of 5,000 seconds. The systematic frequency shifts were corrected with a total uncertainty of 1.7 × 10−16. The lattice polarizability shift currently contributes the largest source. This work paves the way to measuring the absolute clock transition frequency relative to the primary Cs standard or against the International System of Units (SI) second.
The experimental comparison of two thulium optical lattice clocks in a time interval of up to one hour has been carried out. The synchronous comparison of a clock transition in two independent atomic ensembles using a single ultrastable laser has allowed us to eliminate fluctuations of the laser frequency from the measured frequency difference and to reach a relative measurement error of 10–16 after 500-s averaging, which corresponds to a relative instability of 2×10−15/τ2 \times {{10}^{{ - 15}}}{\text{/}}\sqrt \tau 2×10−15/τ​ . The successful demonstration of the long-term operation of two systems using the synchronous comparison of clock transitions opens the possibility of studying systematic shifts in thulium optical clocks with an uncertainty of 10–17.
Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.