Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Optica Sinica

通过减小碰撞导致的退相干和谱线增宽提高光晶格钟稳定度

Chihua Zhou, Xiaotong Lu, 郭峰 Guo Feng, 王叶兵 Wang Yebing, Ting Liang, Hong Chang

Published Jan 1, 2023• 0 citations
Publisher

Abstract

Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.

DOI
10.3788/aos221849

Related papers

一维光晶格中原子的光学黏团冷却与轴向边带冷却

夏京京 Xia Jingjing, 郭峰 Guo Feng, 刘艳艳 Liu Yanyan +2 more

Objective We aim to reduce the temperature of cold atoms in a one-dimensional optical lattice, as this can remarkably enhance atomic coherence time and thereby improve the performance of applications like quantum simulation, optical lattice clocks, and quantum computing. In a one-dimensional optical lattice clock, atoms that have undergone two-stage Doppler cooling are confined within the lattice. The lattice has strong confinement only in the polarization direction and weaker confinement in the other two directions, which leads to radial heating effects. Moreover, since cold atoms occupy different motional states within the lattice and follow a Boltzmann thermal distribution, using a clock laser to probe the atoms confined in the optical lattice can result in inhomogenous excitation due to the dependence of motional states on Rabi frequency. This inhomogeneity reduces the indistinguishability of fermions, introduces additional collision frequency shifts, and weakens the coherence between the laser and the atoms, ultimately decreasing the detection time. Consequently, it becomes impossible to obtain narrow linewidth clock transition spectra with high signal-to-noise ratios, further affecting the stability of the optical lattice clock and the level of quantum control. Even at μK temperatures, the Doppler broadening can still reach tens of kHz. Cooling the atom ensemble using the damping force generated by standing wave fields can effectively reduce the temperature. To further lower the temperature of the atoms, various sub-Doppler cooling techniques are employed to cool the trapped atoms to their vibrational ground state, such as evaporative cooling and Raman sideband cooling. However, evaporative cooling requires long evaporation times and significant atomic loss, making it unsuitable for many applications. In contrast, the effectiveness of Raman sideband cooling can rival that of ion traps, making this cooling method widely applicable in optical clocks and optical tweezers. In this work, we apply optical molasses cooling and longitudinal Raman sideband cooling in a one-dimensional optical lattice to effectively lower the temperature of the cold atom ensemble and enhance coherence. Methods Based on the 87Sr optical lattice clock, the atomic temperature is cooled to the μK level after two-stage laser cooling and is confined in a one-dimensional optical lattice with a trap depth of U=182Er. Using three pairs of orthogonal 689 nm lasers, a standing wave field is formed. By adjusting the frequency and power, the optical molasses cooling further lowers the temperature under the influence of three-dimensional damping forces. For the prepared quantum reference system, an appropriate bias magnetic field is applied, making the energy level shift of 1S0 indistinguishable, while the energy level shift of 3P1 is highly resolvable. At this point, a 698 nm cooling laser is applied along the polarization direction of the lattice light (+Z direction), with its frequency set to the red-detuned resonance frequency of the clock transition. This excites the atoms from the |1S0,|n〉 state to the |3P0,|n-1〉 state. Due to the long lifetime of the excited state 3P0 [151.4(48) s], atoms cannot spontaneously return to the ground state quickly enough for effective cooling. Therefore, a 679 nm repumping laser is used to pump the atoms from the 3P0 state to the 3S1 state, allowing spontaneous relaxation to 3P2, 3P1, and 3P0 states. Only the 3P1 state can spontaneously relax back to |1S0,|n-1〉. Thus, a 707 nm repumping laser is applied to pump the atoms from the 3P2 state to the 3S1 state, ensuring that all populations return to the ground state |1S0,|n-1〉 via the 3P1 state. The entire cooling process lasts about 30 ms, with the sideband cooling light circulating 5 times to improve cooling efficiency. Finally, two 698 nm clock lasers probe the atoms, achieving the axial and radial clock laser resonant transitions between (5s2) 1S0(F=9/2)-(5s5p) 3P0(F=9/2), with the radial clock laser acting for 5 ms. Results and Discussions Through the optimization of the frequency and power of the 689 nm laser, optical lattice cooling successfully reduce the radial temperature of the atoms from 14.6 μK to 8 μK (Fig. 2). Longitudinal sideband cooling further lowers the axial temperature of the atoms from 5.6 μK to 1.2 μK (Fig. 2), decreasing the average external vibrational quantum number from 0.82 to 0.02. By observing Rabi oscillations (Fig. 3), the combination of optical molasses cooling and sideband cooling improves the maximum excitation fraction from 0.85 to 0.95, reduces inhomogeneous excitation, and increases the coherence time of the laser and atoms. Additionally, by measuring the atom fractions under different trap depths (Fig. 4), we demonstrate that our method increases low-temperature atom number in the lattice. This effect contributes to achieving higher stability for optical lattice clocks under lower quantum projection noise (QPN), particularly for shallow lattice clocks. Conclusions Optical molasses cooling and longitudinal sideband cooling effectively reduce the axial temperature of 87Sr atoms to 1/5 of the temperature without cooling while also lowering the radial temperature. After cooling, the average vibrational state of the atoms is 0.02, with over 98.4% of the atoms in the vibrational ground state. The maximum excitation fraction increases from 0.85 to 0.95, indicating that this cooling method enhances coherence. Moreover, remaining atom fraction under different trap depths also show that cooling increases the atomic population. This research helps improve coherence time and the atom number in shallow optical lattices, thus enhancing the performance of quantum applications such as optical lattice atomic clocks. This cooling method can also be extended to other atoms, including 171Yb, 199Hg, and 111Cd. In future work, high-power lasers and three-dimensional sideband cooling can be utilized to cool atomic temperatures to the tens of nK, enhancing atomic coherence and increasing the atom number in shallow lattices, thereby improving the level of quantum control.

Acta Optica Sinica•Jan 1, 2025•2 citations

Comparison of Two Independent Sr Optical Clocks with 1 × 10 − 17 Stability at 10 3 s

Travis Nicholson, Michael J. Martin, Jason Williams +5 more

Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two $^{87}\mathrm{Sr}$ lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.

arXiv:1210.0064•Physical Review Letters•Dec 5, 2012•249 citations

基于腔增强的镱原子光晶格系统研究

江子文 Zi-wen JIANG, 唐颖 Ying TANG, 黄攀 Pan HUANG +3 more

ObjectiveNeutral atomic optical lattice clocks are based on the frequency transition of cold atoms trapped in the magic wavelength optical lattice as the frequency reference, and the frequency stability and uncertainty can reach the order of 10-19, which is a popular research in the field of time-frequency. The realization of the magic wavelength optical lattice with a reinforced cavity can greatly reduce the power requirement of the lattice laser. Cavity-enhanced optical lattice can achieve a large lattice waist with limited optical power, thereby significantly reducing the collision frequency shift between atoms. It also contributes to improve the transfer efficiency of cold atoms to the optical lattice and reduce the quantum projection noise.MethodsWe built a vacuum cavity-enhanced optical lattice system at magic wavelength for ytterbium optical clocks. Using the Pound-Drever-Hall (PDH) technique for laser frequency stabilization, we achieved accurate frequency control of 759 nm lattice laser as well as the enhancement cavity. The frequency noise of the enhancement cavity was evaluated by the error signal. We also analyzed the heating effect of the lattice on the trapped atoms, suppressed the heating effect by power stabilization, and then analyzed the lifetime of the optical lattice by monitoring the spectrum of transmitted signal intensity.Results and DiscussionsThe cavity enhancement factor reached 640 times. By measuring the intensity noise and power spectral density of the transmitted light in the cavity, we evaluated the lifetime of the optical lattice at different well depths, and the optical lattice lifetime can reach more than 10 seconds at a typical well depth of 10 μK.ConclusionsWe have built a vacuum cavity-enhanced optical lattice system for ytterbium atomic optical clocks which can use low-power, high-stability semiconductor lasers as lattice light sources, laying the foundation for further miniaturization and portability of atomic optical clocks.

Acta Sinica Quantum Optica•Jan 1, 2024•0 citations

Quantum Metrology and Many-Body Physics: Pushing the Frontier of the Optical Lattice Clock

Michael J. Martin

Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.

•Jan 1, 2013•34 citations

Frequency comparison of optical lattice clocks

Masao Takamoto, T. Takano, Hidetoshi Katori

We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•0 citations

Interrogation of optical Ramsey spectrum and stability study of an 87Sr optical lattice clock

Jingjing Xia, Xiaotong Lu, Hong Chang

The optical Ramsey spectrum is experimentally realized in an 87Sr optical lattice clock, and the measured linewidth agrees well with theoretical expectation. The coherence time between the clock laser and the atoms, which indicates the maximum free evolution period of using Ramsey detection to measure the atom-laser phase information, is determined as 340(23) ms by measuring the fringe contrasts of the Ramsey spectrum as a function of the free evolution period. Furthermore, with the same clock duty cycle of about 0.1, the clock stability is measured by using the Ramsey and Rabi spectra, respectively. The experimental and theoretical results show approximately the same stability as the two detection methods, which indicates that Ramsey detection cannot obviously improve the clock stability until the clock duty cycle is large enough. Thus, it is of great significance to choose the detection method of a specific clock.

Chinese Physics B•Jul 7, 2021•2 citations
Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.
Objective We aim to reduce the temperature of cold atoms in a one-dimensional optical lattice, as this can remarkably enhance atomic coherence time and thereby improve the performance of applications like quantum simulation, optical lattice clocks, and quantum computing. In a one-dimensional optical lattice clock, atoms that have undergone two-stage Doppler cooling are confined within the lattice. The lattice has strong confinement only in the polarization direction and weaker confinement in the other two directions, which leads to radial heating effects. Moreover, since cold atoms occupy different motional states within the lattice and follow a Boltzmann thermal distribution, using a clock laser to probe the atoms confined in the optical lattice can result in inhomogenous excitation due to the dependence of motional states on Rabi frequency. This inhomogeneity reduces the indistinguishability of fermions, introduces additional collision frequency shifts, and weakens the coherence between the laser and the atoms, ultimately decreasing the detection time. Consequently, it becomes impossible to obtain narrow linewidth clock transition spectra with high signal-to-noise ratios, further affecting the stability of the optical lattice clock and the level of quantum control. Even at μK temperatures, the Doppler broadening can still reach tens of kHz. Cooling the atom ensemble using the damping force generated by standing wave fields can effectively reduce the temperature. To further lower the temperature of the atoms, various sub-Doppler cooling techniques are employed to cool the trapped atoms to their vibrational ground state, such as evaporative cooling and Raman sideband cooling. However, evaporative cooling requires long evaporation times and significant atomic loss, making it unsuitable for many applications. In contrast, the effectiveness of Raman sideband cooling can rival that of ion traps, making this cooling method widely applicable in optical clocks and optical tweezers. In this work, we apply optical molasses cooling and longitudinal Raman sideband cooling in a one-dimensional optical lattice to effectively lower the temperature of the cold atom ensemble and enhance coherence. Methods Based on the 87Sr optical lattice clock, the atomic temperature is cooled to the μK level after two-stage laser cooling and is confined in a one-dimensional optical lattice with a trap depth of U=182Er. Using three pairs of orthogonal 689 nm lasers, a standing wave field is formed. By adjusting the frequency and power, the optical molasses cooling further lowers the temperature under the influence of three-dimensional damping forces. For the prepared quantum reference system, an appropriate bias magnetic field is applied, making the energy level shift of 1S0 indistinguishable, while the energy level shift of 3P1 is highly resolvable. At this point, a 698 nm cooling laser is applied along the polarization direction of the lattice light (+Z direction), with its frequency set to the red-detuned resonance frequency of the clock transition. This excites the atoms from the |1S0,|n〉 state to the |3P0,|n-1〉 state. Due to the long lifetime of the excited state 3P0 [151.4(48) s], atoms cannot spontaneously return to the ground state quickly enough for effective cooling. Therefore, a 679 nm repumping laser is used to pump the atoms from the 3P0 state to the 3S1 state, allowing spontaneous relaxation to 3P2, 3P1, and 3P0 states. Only the 3P1 state can spontaneously relax back to |1S0,|n-1〉. Thus, a 707 nm repumping laser is applied to pump the atoms from the 3P2 state to the 3S1 state, ensuring that all populations return to the ground state |1S0,|n-1〉 via the 3P1 state. The entire cooling process lasts about 30 ms, with the sideband cooling light circulating 5 times to improve cooling efficiency. Finally, two 698 nm clock lasers probe the atoms, achieving the axial and radial clock laser resonant transitions between (5s2) 1S0(F=9/2)-(5s5p) 3P0(F=9/2), with the radial clock laser acting for 5 ms. Results and Discussions Through the optimization of the frequency and power of the 689 nm laser, optical lattice cooling successfully reduce the radial temperature of the atoms from 14.6 μK to 8 μK (Fig. 2). Longitudinal sideband cooling further lowers the axial temperature of the atoms from 5.6 μK to 1.2 μK (Fig. 2), decreasing the average external vibrational quantum number from 0.82 to 0.02. By observing Rabi oscillations (Fig. 3), the combination of optical molasses cooling and sideband cooling improves the maximum excitation fraction from 0.85 to 0.95, reduces inhomogeneous excitation, and increases the coherence time of the laser and atoms. Additionally, by measuring the atom fractions under different trap depths (Fig. 4), we demonstrate that our method increases low-temperature atom number in the lattice. This effect contributes to achieving higher stability for optical lattice clocks under lower quantum projection noise (QPN), particularly for shallow lattice clocks. Conclusions Optical molasses cooling and longitudinal sideband cooling effectively reduce the axial temperature of 87Sr atoms to 1/5 of the temperature without cooling while also lowering the radial temperature. After cooling, the average vibrational state of the atoms is 0.02, with over 98.4% of the atoms in the vibrational ground state. The maximum excitation fraction increases from 0.85 to 0.95, indicating that this cooling method enhances coherence. Moreover, remaining atom fraction under different trap depths also show that cooling increases the atomic population. This research helps improve coherence time and the atom number in shallow optical lattices, thus enhancing the performance of quantum applications such as optical lattice atomic clocks. This cooling method can also be extended to other atoms, including 171Yb, 199Hg, and 111Cd. In future work, high-power lasers and three-dimensional sideband cooling can be utilized to cool atomic temperatures to the tens of nK, enhancing atomic coherence and increasing the atom number in shallow lattices, thereby improving the level of quantum control.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr^{87}\mathrm{Sr}87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
ObjectiveNeutral atomic optical lattice clocks are based on the frequency transition of cold atoms trapped in the magic wavelength optical lattice as the frequency reference, and the frequency stability and uncertainty can reach the order of 10-19, which is a popular research in the field of time-frequency. The realization of the magic wavelength optical lattice with a reinforced cavity can greatly reduce the power requirement of the lattice laser. Cavity-enhanced optical lattice can achieve a large lattice waist with limited optical power, thereby significantly reducing the collision frequency shift between atoms. It also contributes to improve the transfer efficiency of cold atoms to the optical lattice and reduce the quantum projection noise.MethodsWe built a vacuum cavity-enhanced optical lattice system at magic wavelength for ytterbium optical clocks. Using the Pound-Drever-Hall (PDH) technique for laser frequency stabilization, we achieved accurate frequency control of 759 nm lattice laser as well as the enhancement cavity. The frequency noise of the enhancement cavity was evaluated by the error signal. We also analyzed the heating effect of the lattice on the trapped atoms, suppressed the heating effect by power stabilization, and then analyzed the lifetime of the optical lattice by monitoring the spectrum of transmitted signal intensity.Results and DiscussionsThe cavity enhancement factor reached 640 times. By measuring the intensity noise and power spectral density of the transmitted light in the cavity, we evaluated the lifetime of the optical lattice at different well depths, and the optical lattice lifetime can reach more than 10 seconds at a typical well depth of 10 μK.ConclusionsWe have built a vacuum cavity-enhanced optical lattice system for ytterbium atomic optical clocks which can use low-power, high-stability semiconductor lasers as lattice light sources, laying the foundation for further miniaturization and portability of atomic optical clocks.
Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.
We demonstrate the frequency comparison of two optical lattice clocks at the relative stabilities close to the quantum projection noise (QPN) limit of optical lattice clocks. This stable frequency comparison is accomplished by synchronous interrogations of two clocks by a common probe laser, which allows us to cancel out the probe laser's frequency noise. We perform the frequency comparison of a one-dimensional (1D) optical lattice clock with spin-polarized fermions 87Sr and a three-dimensional (3D) optical lattice clock with unity-occupation bosons 88Sr and achieve the Allan standard deviation of σγ(τ)=4×10-16 τ-1/2, which corresponds to the QPN limited stability for N=1,000 atoms and the spectrum linewidth γ=8 Hz. The relative stability reaches 1×10-17 with an averaging time of 1,600 s. Finally, we discuss the prospects to realize 10-18 fractional inaccuracies and the possible application of frequency comparison with synchronous interrogations to remote clocks' comparison for relativistic geodesy.
The optical Ramsey spectrum is experimentally realized in an 87Sr optical lattice clock, and the measured linewidth agrees well with theoretical expectation. The coherence time between the clock laser and the atoms, which indicates the maximum free evolution period of using Ramsey detection to measure the atom-laser phase information, is determined as 340(23) ms by measuring the fringe contrasts of the Ramsey spectrum as a function of the free evolution period. Furthermore, with the same clock duty cycle of about 0.1, the clock stability is measured by using the Ramsey and Rabi spectra, respectively. The experimental and theoretical results show approximately the same stability as the two detection methods, which indicates that Ramsey detection cannot obviously improve the clock stability until the clock duty cycle is large enough. Thus, it is of great significance to choose the detection method of a specific clock.