ObjectiveNeutral atomic optical lattice clocks are based on the frequency transition of cold atoms trapped in the magic wavelength optical lattice as the frequency reference, and the frequency stability and uncertainty can reach the order of 10-19, which is a popular research in the field of time-frequency. The realization of the magic wavelength optical lattice with a reinforced cavity can greatly reduce the power requirement of the lattice laser. Cavity-enhanced optical lattice can achieve a large lattice waist with limited optical power, thereby significantly reducing the collision frequency shift between atoms. It also contributes to improve the transfer efficiency of cold atoms to the optical lattice and reduce the quantum projection noise.MethodsWe built a vacuum cavity-enhanced optical lattice system at magic wavelength for ytterbium optical clocks. Using the Pound-Drever-Hall (PDH) technique for laser frequency stabilization, we achieved accurate frequency control of 759 nm lattice laser as well as the enhancement cavity. The frequency noise of the enhancement cavity was evaluated by the error signal. We also analyzed the heating effect of the lattice on the trapped atoms, suppressed the heating effect by power stabilization, and then analyzed the lifetime of the optical lattice by monitoring the spectrum of transmitted signal intensity.Results and DiscussionsThe cavity enhancement factor reached 640 times. By measuring the intensity noise and power spectral density of the transmitted light in the cavity, we evaluated the lifetime of the optical lattice at different well depths, and the optical lattice lifetime can reach more than 10 seconds at a typical well depth of 10 μK.ConclusionsWe have built a vacuum cavity-enhanced optical lattice system for ytterbium atomic optical clocks which can use low-power, high-stability semiconductor lasers as lattice light sources, laying the foundation for further miniaturization and portability of atomic optical clocks.
ObjectiveNeutral atomic optical lattice clocks are based on the frequency transition of cold atoms trapped in the magic wavelength optical lattice as the frequency reference, and the frequency stability and uncertainty can reach the order of 10-19, which is a popular research in the field of time-frequency. The realization of the magic wavelength optical lattice with a reinforced cavity can greatly reduce the power requirement of the lattice laser. Cavity-enhanced optical lattice can achieve a large lattice waist with limited optical power, thereby significantly reducing the collision frequency shift between atoms. It also contributes to improve the transfer efficiency of cold atoms to the optical lattice and reduce the quantum projection noise.MethodsWe built a vacuum cavity-enhanced optical lattice system at magic wavelength for ytterbium optical clocks. Using the Pound-Drever-Hall (PDH) technique for laser frequency stabilization, we achieved accurate frequency control of 759 nm lattice laser as well as the enhancement cavity. The frequency noise of the enhancement cavity was evaluated by the error signal. We also analyzed the heating effect of the lattice on the trapped atoms, suppressed the heating effect by power stabilization, and then analyzed the lifetime of the optical lattice by monitoring the spectrum of transmitted signal intensity.Results and DiscussionsThe cavity enhancement factor reached 640 times. By measuring the intensity noise and power spectral density of the transmitted light in the cavity, we evaluated the lifetime of the optical lattice at different well depths, and the optical lattice lifetime can reach more than 10 seconds at a typical well depth of 10 μK.ConclusionsWe have built a vacuum cavity-enhanced optical lattice system for ytterbium atomic optical clocks which can use low-power, high-stability semiconductor lasers as lattice light sources, laying the foundation for further miniaturization and portability of atomic optical clocks.
We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock. It is demonstrated that the intra-cavity lattice power can be increased by about 45 times, and the trap depth can be as large as 1400E r when laser light with a power of only 0.6 W incident to the lattice cavity. Such high trap depths are the key to accurate evaluation of the lattice-induced light shift with an uncertainty down to ∼1 × 10−18. By probing the ytterbium atoms trapped in the power-enhanced optical lattice, we obtain a 4.3 Hz-linewidth Rabi spectrum, which is then used to feedback to the clock laser for the close loop operation of the optical lattice clock. We evaluate the density shift of the Yb optical lattice clock based on interleaving measurements, which is –0.46(62) mHz. This result is smaller compared to the density shift of our first Yb optical clock without lattice power enhancement cavity mainly due to a larger lattice diameter of 344 μm.
Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.
Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.
Objective We aim to reduce the temperature of cold atoms in a one-dimensional optical lattice, as this can remarkably enhance atomic coherence time and thereby improve the performance of applications like quantum simulation, optical lattice clocks, and quantum computing. In a one-dimensional optical lattice clock, atoms that have undergone two-stage Doppler cooling are confined within the lattice. The lattice has strong confinement only in the polarization direction and weaker confinement in the other two directions, which leads to radial heating effects. Moreover, since cold atoms occupy different motional states within the lattice and follow a Boltzmann thermal distribution, using a clock laser to probe the atoms confined in the optical lattice can result in inhomogenous excitation due to the dependence of motional states on Rabi frequency. This inhomogeneity reduces the indistinguishability of fermions, introduces additional collision frequency shifts, and weakens the coherence between the laser and the atoms, ultimately decreasing the detection time. Consequently, it becomes impossible to obtain narrow linewidth clock transition spectra with high signal-to-noise ratios, further affecting the stability of the optical lattice clock and the level of quantum control. Even at μK temperatures, the Doppler broadening can still reach tens of kHz. Cooling the atom ensemble using the damping force generated by standing wave fields can effectively reduce the temperature. To further lower the temperature of the atoms, various sub-Doppler cooling techniques are employed to cool the trapped atoms to their vibrational ground state, such as evaporative cooling and Raman sideband cooling. However, evaporative cooling requires long evaporation times and significant atomic loss, making it unsuitable for many applications. In contrast, the effectiveness of Raman sideband cooling can rival that of ion traps, making this cooling method widely applicable in optical clocks and optical tweezers. In this work, we apply optical molasses cooling and longitudinal Raman sideband cooling in a one-dimensional optical lattice to effectively lower the temperature of the cold atom ensemble and enhance coherence. Methods Based on the 87Sr optical lattice clock, the atomic temperature is cooled to the μK level after two-stage laser cooling and is confined in a one-dimensional optical lattice with a trap depth of U=182Er. Using three pairs of orthogonal 689 nm lasers, a standing wave field is formed. By adjusting the frequency and power, the optical molasses cooling further lowers the temperature under the influence of three-dimensional damping forces. For the prepared quantum reference system, an appropriate bias magnetic field is applied, making the energy level shift of 1S0 indistinguishable, while the energy level shift of 3P1 is highly resolvable. At this point, a 698 nm cooling laser is applied along the polarization direction of the lattice light (+Z direction), with its frequency set to the red-detuned resonance frequency of the clock transition. This excites the atoms from the |1S0,|n〉 state to the |3P0,|n-1〉 state. Due to the long lifetime of the excited state 3P0 [151.4(48) s], atoms cannot spontaneously return to the ground state quickly enough for effective cooling. Therefore, a 679 nm repumping laser is used to pump the atoms from the 3P0 state to the 3S1 state, allowing spontaneous relaxation to 3P2, 3P1, and 3P0 states. Only the 3P1 state can spontaneously relax back to |1S0,|n-1〉. Thus, a 707 nm repumping laser is applied to pump the atoms from the 3P2 state to the 3S1 state, ensuring that all populations return to the ground state |1S0,|n-1〉 via the 3P1 state. The entire cooling process lasts about 30 ms, with the sideband cooling light circulating 5 times to improve cooling efficiency. Finally, two 698 nm clock lasers probe the atoms, achieving the axial and radial clock laser resonant transitions between (5s2) 1S0(F=9/2)-(5s5p) 3P0(F=9/2), with the radial clock laser acting for 5 ms. Results and Discussions Through the optimization of the frequency and power of the 689 nm laser, optical lattice cooling successfully reduce the radial temperature of the atoms from 14.6 μK to 8 μK (Fig. 2). Longitudinal sideband cooling further lowers the axial temperature of the atoms from 5.6 μK to 1.2 μK (Fig. 2), decreasing the average external vibrational quantum number from 0.82 to 0.02. By observing Rabi oscillations (Fig. 3), the combination of optical molasses cooling and sideband cooling improves the maximum excitation fraction from 0.85 to 0.95, reduces inhomogeneous excitation, and increases the coherence time of the laser and atoms. Additionally, by measuring the atom fractions under different trap depths (Fig. 4), we demonstrate that our method increases low-temperature atom number in the lattice. This effect contributes to achieving higher stability for optical lattice clocks under lower quantum projection noise (QPN), particularly for shallow lattice clocks. Conclusions Optical molasses cooling and longitudinal sideband cooling effectively reduce the axial temperature of 87Sr atoms to 1/5 of the temperature without cooling while also lowering the radial temperature. After cooling, the average vibrational state of the atoms is 0.02, with over 98.4% of the atoms in the vibrational ground state. The maximum excitation fraction increases from 0.85 to 0.95, indicating that this cooling method enhances coherence. Moreover, remaining atom fraction under different trap depths also show that cooling increases the atomic population. This research helps improve coherence time and the atom number in shallow optical lattices, thus enhancing the performance of quantum applications such as optical lattice atomic clocks. This cooling method can also be extended to other atoms, including 171Yb, 199Hg, and 111Cd. In future work, high-power lasers and three-dimensional sideband cooling can be utilized to cool atomic temperatures to the tens of nK, enhancing atomic coherence and increasing the atom number in shallow lattices, thereby improving the level of quantum control.
The optical lattice clock with neutral atoms occupies an outstanding position in the research field of atomic clocks, demonstrating the great potential of its performance (like the uncertainty and the stability). At present, the optical lattice clock has realized a 10-18 level of its uncertainty. In this paper, we present the realization of loading bosonic atoms 88Sr (strontium, alkaline-earth metals) into a one-dimensional (1D) optical lattice in our laboratory. The optical lattice where the atoms are trapped can make the energy level shift, called Stark shift. But there is the special optical lattice operating at the “magic” wavelength for clock transitions (5s2) 1S0-(5s5p) 3P0, which can make the same Stark light-shift for both of them, indicating a zero light-shift relative to the clock. In our experiment, Sr atoms are cooled in a two-stage cooling and its temperature can be as low as 2 μK. Then these cold atoms are confined in the Lamb-Dicke region by the lattice laser output from an amplified diode laser operating at the “magic” wavelength, 813 nm. Experimentally, it is straightforward to provide 850 mW of lattice power focused to a 38 μm beam radius. After the cold atoms have trapped in the optical lattice, the lifetime of atoms in 1D optical lattice is measured to be 270 ms. The temperature and the number are about 3.5 μK and 1.2×105 respectively. Besides, effects of the power of the lattice laser on both the number and temperature are analyzed. The number changes linearly with the laser power, while there is no obvious influence on the temperature by the power. This original and special approach for atoms trapped in the optical lattice can provide a long interrogation time for probing the clock transition. Furthermore, it may be the foundation for developing our optical lattice clock of strontium atoms.
We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.