Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Improving lattice-light-shift uncertainty of an 171Yb optical clock with optimized cooling and trapping lasers

Chengquan Peng, Tao Zhang, Changyue Sun, Qichao Qi, Taoyun Jin, Shuai Lei, Chengcheng Zhao, Suzhen Feng, Yan Xia, Xinye Xu

Published Sep 9, 2024• 2 citations
Publisher

Abstract

Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.

DOI
10.1063/5.0222370

Related papers

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•3 citations

Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock

Roger C. Brown, Nate Phillips, K. Beloy +11 more

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

arXiv:1708.08829•Physical Review Letters•Dec 19, 2017•115 citations

Investigation of the 4f146s2 1S0−4f135d6s2 (J = 2) clock transition at 431 nm of 171Yb atoms trapped in an optical lattice

Congyu Wang, Yuan Yao, Haosen Shi +3 more

With the aid of an optical frequency divider based on an optical frequency comb, the frequency of a laser at 431 nm is divided from a cavity-stabilized laser at 578 nm. Using the frequency-stabilized 431 nm laser, we observe a 2.5 kHz linewidth 4f146s2 1S0−4f135d6s2 (J = 2) transition of 171Yb atoms trapped in an optical lattice. By measuring the lattice-induced frequency shift, we determine the magic wavelength of the optical lattice for the 431 nm transition to be 797.97(20) nm. The frequency of the 431 nm transition is measured to be 695 171 054 856.9(1.1) kHz by referencing to the 1S0−3P0 transition at 578 nm of Yb atoms.

Applied Physics Letters•Jan 20, 2025•4 citations

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•31 citations

Ytterbium optical lattice clock at INRIM

Marco Pizzocaro, Filippo Bregolin, Gianmaria Milani +5 more

We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•1 citation

基于腔增强的镱原子光晶格系统研究

江子文 Zi-wen JIANG, 唐颖 Ying TANG, 黄攀 Pan HUANG +3 more

ObjectiveNeutral atomic optical lattice clocks are based on the frequency transition of cold atoms trapped in the magic wavelength optical lattice as the frequency reference, and the frequency stability and uncertainty can reach the order of 10-19, which is a popular research in the field of time-frequency. The realization of the magic wavelength optical lattice with a reinforced cavity can greatly reduce the power requirement of the lattice laser. Cavity-enhanced optical lattice can achieve a large lattice waist with limited optical power, thereby significantly reducing the collision frequency shift between atoms. It also contributes to improve the transfer efficiency of cold atoms to the optical lattice and reduce the quantum projection noise.MethodsWe built a vacuum cavity-enhanced optical lattice system at magic wavelength for ytterbium optical clocks. Using the Pound-Drever-Hall (PDH) technique for laser frequency stabilization, we achieved accurate frequency control of 759 nm lattice laser as well as the enhancement cavity. The frequency noise of the enhancement cavity was evaluated by the error signal. We also analyzed the heating effect of the lattice on the trapped atoms, suppressed the heating effect by power stabilization, and then analyzed the lifetime of the optical lattice by monitoring the spectrum of transmitted signal intensity.Results and DiscussionsThe cavity enhancement factor reached 640 times. By measuring the intensity noise and power spectral density of the transmitted light in the cavity, we evaluated the lifetime of the optical lattice at different well depths, and the optical lattice lifetime can reach more than 10 seconds at a typical well depth of 10 μK.ConclusionsWe have built a vacuum cavity-enhanced optical lattice system for ytterbium atomic optical clocks which can use low-power, high-stability semiconductor lasers as lattice light sources, laying the foundation for further miniaturization and portability of atomic optical clocks.

Acta Sinica Quantum Optica•Jan 1, 2024•0 citations
Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.
With the aid of an optical frequency divider based on an optical frequency comb, the frequency of a laser at 431 nm is divided from a cavity-stabilized laser at 578 nm. Using the frequency-stabilized 431 nm laser, we observe a 2.5 kHz linewidth 4f146s2 1S0−4f135d6s2 (J = 2) transition of 171Yb atoms trapped in an optical lattice. By measuring the lattice-induced frequency shift, we determine the magic wavelength of the optical lattice for the 431 nm transition to be 797.97(20) nm. The frequency of the 431 nm transition is measured to be 695 171 054 856.9(1.1) kHz by referencing to the 1S0−3P0 transition at 578 nm of Yb atoms.
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.
We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.
ObjectiveNeutral atomic optical lattice clocks are based on the frequency transition of cold atoms trapped in the magic wavelength optical lattice as the frequency reference, and the frequency stability and uncertainty can reach the order of 10-19, which is a popular research in the field of time-frequency. The realization of the magic wavelength optical lattice with a reinforced cavity can greatly reduce the power requirement of the lattice laser. Cavity-enhanced optical lattice can achieve a large lattice waist with limited optical power, thereby significantly reducing the collision frequency shift between atoms. It also contributes to improve the transfer efficiency of cold atoms to the optical lattice and reduce the quantum projection noise.MethodsWe built a vacuum cavity-enhanced optical lattice system at magic wavelength for ytterbium optical clocks. Using the Pound-Drever-Hall (PDH) technique for laser frequency stabilization, we achieved accurate frequency control of 759 nm lattice laser as well as the enhancement cavity. The frequency noise of the enhancement cavity was evaluated by the error signal. We also analyzed the heating effect of the lattice on the trapped atoms, suppressed the heating effect by power stabilization, and then analyzed the lifetime of the optical lattice by monitoring the spectrum of transmitted signal intensity.Results and DiscussionsThe cavity enhancement factor reached 640 times. By measuring the intensity noise and power spectral density of the transmitted light in the cavity, we evaluated the lifetime of the optical lattice at different well depths, and the optical lattice lifetime can reach more than 10 seconds at a typical well depth of 10 μK.ConclusionsWe have built a vacuum cavity-enhanced optical lattice system for ytterbium atomic optical clocks which can use low-power, high-stability semiconductor lasers as lattice light sources, laying the foundation for further miniaturization and portability of atomic optical clocks.