Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Improving lattice-light-shift uncertainty of an 171Yb optical clock with optimized cooling and trapping lasers

Chengquan Peng, Tao Zhang, Changyue Sun, Qichao Qi, Taoyun Jin, Shuai Lei, Chengcheng Zhao, Suzhen Feng, Yan Xia, Xinye Xu

Published Sep 9, 2024• 2 citations
Publisher

Abstract

Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.

DOI
10.1063/5.0222370

Related papers

Investigation of the 4f146s2 1S0−4f135d6s2 (J = 2) clock transition at 431 nm of 171Yb atoms trapped in an optical lattice

Congyu Wang, Yuan Yao, Haosen Shi +3 more

With the aid of an optical frequency divider based on an optical frequency comb, the frequency of a laser at 431 nm is divided from a cavity-stabilized laser at 578 nm. Using the frequency-stabilized 431 nm laser, we observe a 2.5 kHz linewidth 4f146s2 1S0−4f135d6s2 (J = 2) transition of 171Yb atoms trapped in an optical lattice. By measuring the lattice-induced frequency shift, we determine the magic wavelength of the optical lattice for the 431 nm transition to be 797.97(20) nm. The frequency of the 431 nm transition is measured to be 695 171 054 856.9(1.1) kHz by referencing to the 1S0−3P0 transition at 578 nm of Yb atoms.

Applied Physics Letters•Jan 20, 2025•3 citations

Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock

Roger C. Brown, Nate Phillips, K. Beloy +11 more

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

arXiv:1708.08829•Physical Review Letters•Dec 19, 2017•101 citations

Ytterbium optical lattice clock at INRIM

Marco Pizzocaro, Filippo Bregolin, Gianmaria Milani +5 more

We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•1 citation

Uncertainty Evaluation of an 171Yb Optical Lattice Clock at NMIJ

Takumi Kobayashi, Daisuke Akamatsu, Yusuke Hisai +6 more

We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

arXiv:1901.00954•IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Sep 18, 2018•26 citations

Magic Wavelength Measurement of the 87 Sr Optical Lattice Clock at NIM

Qiang Wang, Yige Lin, Fei Meng +5 more

We report on the magic wavelength measurement of our optical lattice clock based on fermion strontium atoms at the National Institute of Metrology (NIM). A Ti:sapphire solid state laser locked to a reference cavity inside a temperature-stabilized vacuum chamber is employed to generate the optical lattice. The laser frequency is measured by an erbium fiber frequency comb. The trap depth is modulated by varying the lattice laser power via an acousto-optic modulator. We obtain the frequency shift coefficient at this lattice wavelength by measuring the differential frequency shift of the clock transition of the strontium atoms at different trap depths, and the frequency shift coefficient at this lattice wavelength is obtained. We measure the frequency shift coefficients at different lattice frequencies around the magic wavelength and linearly fit the measurement data, and the magic wavelength is calculated to be 368554672(44) MHz.

Chinese Physics Letters•Oct 1, 2016•9 citations

Realization of advanced 171Yb optical lattice frequency standard

Gianmaria Milani

Atomic clocks constitute a fundamental tool for time and frequency metrology and their application is widespread in many technological fields. In particular, the International System of units (SI) defines the second on a microwave transition of Caesium atoms. The realization is made by clocks reaching uncertainties of few parts in 10^−16, making the second to be the quantity realized with the smallest uncertainty in the SI. However, a new generation of atomic clocks, called optical clocks, have already demonstrated to surpass Caesium standards both in accuracy and stability. The research performed during my PhD activity has been focused on the development and characterization of Ytterbium (Yb) optical lattice clocks. These systems operate with a large number of ultra-cold neutral atoms having a clock transition in the visible region of the electromagnetic spectrum. The atomic sample is trapped in an periodical optical potential called optical lattice that gives the advantage to interrogate many quantum absorbers for an extended time, with small perturbations, allowing to achieve an unprecedented stability and accuracy. The main experimental work has been carried out in the laboratories of the Istituto Nazionale di Ricerca Metrologica (INRIM) in Turin, where several atomic clocks are present including the Italian primary frequency standard, the Caesium fountain ITCsF2, and where an Yb optical lattice clock is currently being developed. This thesis describes the functioning of the system along with the full characterization of systematic effects, the complete uncertainty budget and its first absolute frequency measurement against the primary frequency standard. The clock exhibited an accuracy of 1.6 × 10^−16 and the comparison with the Cs fountain resulted in a frequency of f171Yb = 518 295 836 590 863.59(31) Hz, limited by the fountain uncertainty. This measurement is in agreement with the ytterbium frequency recommended as a secondary representation of the second in the SI and constitutes the first measurement of a Yb clock in Europe and the second one in the world against a primary frequency standard. Several upgrades have been applied after the absolute measurement. In particular, the design and realization a system capable to frequency stabilize several lasers on a single optical cavity is illustrated. This cavity has been implemented to lock the lasers used to cool and trap the atomic sample at 399, 556 and 759nm using the offset sideband locking technique, a modified version of the Pound–Drever–Hall method that gives an extended frequency tunability. The system proved to be an easy-to-use and reliable tool for the experimental activity showing a linewidth below 300 Hz at 556nm, which is the wavelength that requires the most stringent performance, and a long term drift below 20 kHz per day at 759nm. That is suitable for operating the lattice laser with a light shift uncertainty below 1 × 10−18. During my PhD I have been guest researcher at the National Institute of Standards and Technology (NIST) of Boulder, Colorado, for nine months in 2016. In these laboratories two Yb optical lattice clocks are operative. I worked on the instability measurement of a composite system exploiting the two clocks to suppress the Dick effect, called zero-dead-time (ZDT) clock, which demonstrated a fractional instability of 3 × 10−17 at 1s. The two clocks can also be operated to extend the interrogation time obtaining a spectroscopic feature after 4 s of 120(20)mHz corresponding to a quality factor Q > 4 × 10^15. I also worked on the characterization of several systematic shifts that allowed to complete the uncertainty budget of the clocks at 1.6 × 10^−18. In particular, I contributed to the characterization of lattice light shifts considering the effect of atomic sample temperature and the identification of a metrological regime called operational magic frequency where frequency shifts are insensitive to changes in trap depth.

•May 2, 2018•1 citation
Atoms confined in the optical lattice can be interrogated with Doppler- and recoil-free operation. However, if not properly controlled, the optical lattice may limit clock accuracy. To improve the lattice-light-shift uncertainty, the cooling and trapping lasers' frequency stability is optimized, and the atom's signal stability is enhanced. A ring-cavity Ti:sapphire laser is locked to the optical frequency comb, which is referenced to a 578 nm ultra-stable laser, and the beat note's stability is on the order of 10−16. Using a 10 cm Fabry–Pérot cavity referenced to the Ti:sapphire laser, the optical frequency stability is transferred to the 399 nm cooling laser, creating favorable conditions for evaluating the lattice-light-shift accurately. We reevaluate lattice-light-shift in our 171Yb optical lattice clock with an uncertainty of 8.1 × 10−18, which is an order lower than our previous result, and the magic frequency is determined to be 394 798 266.6(1.3) MHz.
With the aid of an optical frequency divider based on an optical frequency comb, the frequency of a laser at 431 nm is divided from a cavity-stabilized laser at 578 nm. Using the frequency-stabilized 431 nm laser, we observe a 2.5 kHz linewidth 4f146s2 1S0−4f135d6s2 (J = 2) transition of 171Yb atoms trapped in an optical lattice. By measuring the lattice-induced frequency shift, we determine the magic wavelength of the optical lattice for the 431 nm transition to be 797.97(20) nm. The frequency of the 431 nm transition is measured to be 695 171 054 856.9(1.1) kHz by referencing to the 1S0−3P0 transition at 578 nm of Yb atoms.
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.
We present an optical lattice clock based on ytterbium 171Yb atoms developed in the laboratories of INRIM. In the experiment, we cool and trap ytterbium atoms in a two stage magneto-optical trap (MOT) (at 399nm and 556nm for the first and second stage, respectively). Atoms are then transferred in a horizontal, one-dimensional optical lattice at the magic wavelength (759 nm). Here the clock transition at 578nm is probed by a laser stabilized on an ultra-stable cavity. We describe the generation of all the laser sources, the physic package and the operation of the clock. Lasers at 399 nm, 556nm and 578nm are obtained, with different techniques, using non-linear crystals starting from infrared sources. The clock laser is stabilized using a high finesse notched ULE cavity. The lattice is made with a titanium-sapphire laser. The aluminum vacuum chamber is designed for wide optical access and its temperature is measured by 8 thermistors for blackbody shift evaluation. Our system allows for fast loading of the lattice with 1 × 104atoms trapped in the lattice in 250 ms. We obtained preliminary spectroscopy results and we locked the clock laser to the atomic line. Future perspectives are discussed.
We report an uncertainty evaluation of an171Yb optical lattice clock with a total fractional uncertainty of 3.6 × 10-16, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the 6s21S0-6s6p3P0clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift d incorporated in a widely used light shift model by RIKEN and the second-order Zeeman shift aZare improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient d is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions 6s6p3P0-6s8p3P0, 6s8p3P2, and 6s5f3F2. The obtained values are d=-1.1(4) μHz and aZ=-6.6(3) Hz/mT2. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.
We report on the magic wavelength measurement of our optical lattice clock based on fermion strontium atoms at the National Institute of Metrology (NIM). A Ti:sapphire solid state laser locked to a reference cavity inside a temperature-stabilized vacuum chamber is employed to generate the optical lattice. The laser frequency is measured by an erbium fiber frequency comb. The trap depth is modulated by varying the lattice laser power via an acousto-optic modulator. We obtain the frequency shift coefficient at this lattice wavelength by measuring the differential frequency shift of the clock transition of the strontium atoms at different trap depths, and the frequency shift coefficient at this lattice wavelength is obtained. We measure the frequency shift coefficients at different lattice frequencies around the magic wavelength and linearly fit the measurement data, and the magic wavelength is calculated to be 368554672(44) MHz.
Atomic clocks constitute a fundamental tool for time and frequency metrology and their application is widespread in many technological fields. In particular, the International System of units (SI) defines the second on a microwave transition of Caesium atoms. The realization is made by clocks reaching uncertainties of few parts in 10^−16, making the second to be the quantity realized with the smallest uncertainty in the SI. However, a new generation of atomic clocks, called optical clocks, have already demonstrated to surpass Caesium standards both in accuracy and stability. The research performed during my PhD activity has been focused on the development and characterization of Ytterbium (Yb) optical lattice clocks. These systems operate with a large number of ultra-cold neutral atoms having a clock transition in the visible region of the electromagnetic spectrum. The atomic sample is trapped in an periodical optical potential called optical lattice that gives the advantage to interrogate many quantum absorbers for an extended time, with small perturbations, allowing to achieve an unprecedented stability and accuracy. The main experimental work has been carried out in the laboratories of the Istituto Nazionale di Ricerca Metrologica (INRIM) in Turin, where several atomic clocks are present including the Italian primary frequency standard, the Caesium fountain ITCsF2, and where an Yb optical lattice clock is currently being developed. This thesis describes the functioning of the system along with the full characterization of systematic effects, the complete uncertainty budget and its first absolute frequency measurement against the primary frequency standard. The clock exhibited an accuracy of 1.6 × 10^−16 and the comparison with the Cs fountain resulted in a frequency of f171Yb = 518 295 836 590 863.59(31) Hz, limited by the fountain uncertainty. This measurement is in agreement with the ytterbium frequency recommended as a secondary representation of the second in the SI and constitutes the first measurement of a Yb clock in Europe and the second one in the world against a primary frequency standard. Several upgrades have been applied after the absolute measurement. In particular, the design and realization a system capable to frequency stabilize several lasers on a single optical cavity is illustrated. This cavity has been implemented to lock the lasers used to cool and trap the atomic sample at 399, 556 and 759nm using the offset sideband locking technique, a modified version of the Pound–Drever–Hall method that gives an extended frequency tunability. The system proved to be an easy-to-use and reliable tool for the experimental activity showing a linewidth below 300 Hz at 556nm, which is the wavelength that requires the most stringent performance, and a long term drift below 20 kHz per day at 759nm. That is suitable for operating the lattice laser with a light shift uncertainty below 1 × 10−18. During my PhD I have been guest researcher at the National Institute of Standards and Technology (NIST) of Boulder, Colorado, for nine months in 2016. In these laboratories two Yb optical lattice clocks are operative. I worked on the instability measurement of a composite system exploiting the two clocks to suppress the Dick effect, called zero-dead-time (ZDT) clock, which demonstrated a fractional instability of 3 × 10−17 at 1s. The two clocks can also be operated to extend the interrogation time obtaining a spectroscopic feature after 4 s of 120(20)mHz corresponding to a quality factor Q > 4 × 10^15. I also worked on the characterization of several systematic shifts that allowed to complete the uncertainty budget of the clocks at 1.6 × 10^−18. In particular, I contributed to the characterization of lattice light shifts considering the effect of atomic sample temperature and the identification of a metrological regime called operational magic frequency where frequency shifts are insensitive to changes in trap depth.