Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Canadian Journal of Physics

Article

Marie-Claude Gagné, J.-S. Boulanger, R J W Douglas

Published Aug 1, 1998• 0 citations
Publisher

Abstract

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

DOI
10.1139/p98-030

Related papers

Cold atoms and cesium fountains at NRC

J.-S. Boulanger, Marie-Claude Gagné, R.J. Douglas

We present a progress report on laser-cooled cesium atoms at NRC, work which was started a few years ago in order to realize a cesium fountain frequency standard. We selected an acceleration with two-dimensional moving molasses, which can increase both the force and the interaction time by a factor of /spl radic/2 over the more common 1-D molasses scheme. This configuration also allows for trapping and cooling of atoms while previously launched atoms are still moving in the clock section of the system. We report measurements on the number of atoms, temperature, friction coefficient and spring constant of our magneto-optical trap and 1-D molasses for various conditions.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 24, 2002•4 citations

Work towards an atomic fountain clock at Peking University

Yimin Li, Jidong Hou, Junxian Fu +3 more

Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•0 citations

An intense, highly collimated continuous Cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

An intense, highly collimated continous cesium fountain

N. Castagna

The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).

•Jan 1, 2006•0 citations

Update on the development of cesium atomic fountain at NPL, India

Poonam Arora, Ashish Agarwal, Kavindra Pant +2 more

National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.

URSI General Assembly and Scientific Symposium•Aug 1, 2011•0 citations

Design and preliminary results of NIM cesium fountain primary frequency standard

Wang Liji, Wu Changhua, Huang Bingying +3 more

We have designed and constructed a cesium fountain as our new generation primary frequency standard. Serial performance measurements of components and assemblies are finished. A cold atomic cloud with diameter 1.5 mm and temperature /spl les/150 /spl mu/K has been observed in a magneto-optical trap set-up. It is used to obtain the optical molasses designed for the fountain clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•1 citation
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
We present a progress report on laser-cooled cesium atoms at NRC, work which was started a few years ago in order to realize a cesium fountain frequency standard. We selected an acceleration with two-dimensional moving molasses, which can increase both the force and the interaction time by a factor of /spl radic/2 over the more common 1-D molasses scheme. This configuration also allows for trapping and cooling of atoms while previously launched atoms are still moving in the clock section of the system. We report measurements on the number of atoms, temperature, friction coefficient and spring constant of our magneto-optical trap and 1-D molasses for various conditions.
Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
The realisation of cold and slow atomic beams has opened the way to a series of precision measurements of high scientific interest, as atom interferometry, Bose-Einstein Condensation and atomic fountain clocks. The latter are used since several years as reference clocks, given the high performance that they can reach both in accuracy and stability. The common philosophy in the construction of atomic fountains has been the pulsed technique, where an atoms sample is launched vertically and then falls down under the effect of the gravity. The Observatoire de Neuchâtel had a different approach and has built a fountain clock (FOCS1) operating in a continuous mode. This technique offers two main advantages: the diminution of the undesirable effects due to the atomic density (e.g. collisions between the atoms and cavity pulling) and to the noise of the local oscillator (intermodulation effect). To take full advantage of the continuous fountain approach however, we need to increase the atomic flux. The techniques chosen to reach this goal are an efficient transverse collimation together with more atoms to begin with. Here we report on a study of different transverse collimation techniques performed in a two-dimensional phase stable optical lattice (namely gray molasses and magnetically induced laser cooling) as well as the development and characterisation of a 2D-magneto-optical trap used to load the fountain. Best performances are reached in a 2D+-MOT configuration of such a pre-source, for which we detect an atomic flux 20 times greater than the one measured when the fountain is loaded by a Cs vapour. This gain could improve the atomic clock stability by a factor 6. An even better stability is expected after introducing a pre-cooling stage before performing the transverse collimation. This new configuration is currently under investigation and will be implemented in a second continuous fountain (FOCS2).
National Physical Laboratory India (NPLI) has been developing a cesium atomic fountain primary frequency standard. We have succeeded in trapping about 107Cs atoms, cool them to about 5 μK by both magneto-optical trap (MOT) and polarization gradient cooling (PGC) and launch them up by moving molasses method. We have demonstrated the fountain action by launching the atoms up to 72.9 cm up and detection of the return signal by measuring the fluorescence. Work is underway to interrogate the launched atoms with microwaves and observe Ramsey fringes.