Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Work towards an atomic fountain clock at Peking University

Yimin Li, Jidong Hou, Junxian Fu, Xuzong Chen, Donghai Yang, Yiqiu Wang

Published Nov 27, 2002• 0 citations
Publisher

Abstract

Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.

DOI
10.1109/freq.1998.717874

Related papers

Article

Marie-Claude Gagné, J.-S. Boulanger, R J W Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Aug 1, 1998•0 citations

Design and preliminary results of NIM cesium fountain primary frequency standard

Wang Liji, Wu Changhua, Huang Bingying +3 more

We have designed and constructed a cesium fountain as our new generation primary frequency standard. Serial performance measurements of components and assemblies are finished. A cold atomic cloud with diameter 1.5 mm and temperature /spl les/150 /spl mu/K has been observed in a magneto-optical trap set-up. It is used to obtain the optical molasses designed for the fountain clock.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•1 citation

Prospects of Russian cesium fountain

Yu.S. Dornnin, G.A. Eolkin, A. V. Novoselov +3 more

We present the current state of things with the development of the Russian cesium fountain. Design of the physical parts, the laser system, and the optical system is briefly outlined. The preliminary results of the operation and detection with a magnetic-optical trap (MOT) and molasses regimes are described. We have made detailed temperature measurements on laser-cooled cesium atoms, exploring a wide range of laser intensity and detuning. The lowest measured temperature of about 20 /spl mu/K for MOT and 2.2 /spl mu/K for molasses are reached.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 8, 2004•0 citations

Cold atoms and cesium fountains at NRC

J.-S. Boulanger, Marie-Claude Gagné, R.J. Douglas

We present a progress report on laser-cooled cesium atoms at NRC, work which was started a few years ago in order to realize a cesium fountain frequency standard. We selected an acceleration with two-dimensional moving molasses, which can increase both the force and the interaction time by a factor of /spl radic/2 over the more common 1-D molasses scheme. This configuration also allows for trapping and cooling of atoms while previously launched atoms are still moving in the clock section of the system. We report measurements on the number of atoms, temperature, friction coefficient and spring constant of our magneto-optical trap and 1-D molasses for various conditions.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Dec 24, 2002•4 citations

Progress towards a laser-cooled cesium atomic fountain frequency standard at NIST, Gaithersburg

William M. Klipstein, Christopher R. Ekstrom, S. L. Rolston +1 more

We report here on progress towards the realization of an atomic frequency standard using a fountain of laser cooled cesium atoms. We have recently observed Ramsey fringes on the 9.2 GHz clock transition and have begun preliminary work aimed at characterizing our fountain. This paper describes briefly the apparatus, discusses our current work and near-term directions. We conclude with a brief discussion of a laser system being built to realize two-dimensional Raman cooling or Raman velocity selection for cooling below the single photon recoil limit. This system will be used either in our fountain or in a cold-atom clock to be flown on the International Space Station.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•2 citations

Atomic Fountain Microwave Clock.

Steven Chu

Abstract : The grant as in support of a research program to explore the possibility of a microwave atomic clock based on an atomic fountain of cesium atoms. During the two year granting period, the following work was done: A large magneto-optic trap in a vapor cell was constructed where over 4x 10(exp 10) atoms were trapped at a density on the order of 10(exp 11) atoms/cu cm. This work increased the number of atoms optically trapped by a factor of -400 compared to previous work. The optical density of the atoms in this trap has a peak attenuation of e(-175). In an invited review article we examined the prospects for slow atom frequency standards. Most of the systematic effects that limit the current accuracy today's frequency standards decrease as the velocity of the atoms is reduced. We identified the one possible exception: collisions between ultra-cold atom in an atomic fountain could induce a phase shift that would ultimately limit the accuracy of the fountain clock. We brought the problem to the attention of B. Verhaar, who began a series of calculations on the effects of low energy collisions. jg p.4

•Jul 7, 1994•0 citations
Cesium atomic fountain clock is the quantum frequency standard with very high accuracy. Research on laser cooling and trapping of cesium atom at Peking University began in 1993. A cesium atomic fountain frequency standard is being developed. A magneto-optical trap with some 108 trapped atoms and an optical molasses with the cold atoms of the temperature of 10/spl mu/K have been achieved previously. The device has been carefully designed and is under construction. It is composed of two main parts: vacuum system and laser system. The article describes the apparatus and presents a brief introduction to some considerations on the atomic clock.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
We present the current state of things with the development of the Russian cesium fountain. Design of the physical parts, the laser system, and the optical system is briefly outlined. The preliminary results of the operation and detection with a magnetic-optical trap (MOT) and molasses regimes are described. We have made detailed temperature measurements on laser-cooled cesium atoms, exploring a wide range of laser intensity and detuning. The lowest measured temperature of about 20 /spl mu/K for MOT and 2.2 /spl mu/K for molasses are reached.
We present a progress report on laser-cooled cesium atoms at NRC, work which was started a few years ago in order to realize a cesium fountain frequency standard. We selected an acceleration with two-dimensional moving molasses, which can increase both the force and the interaction time by a factor of /spl radic/2 over the more common 1-D molasses scheme. This configuration also allows for trapping and cooling of atoms while previously launched atoms are still moving in the clock section of the system. We report measurements on the number of atoms, temperature, friction coefficient and spring constant of our magneto-optical trap and 1-D molasses for various conditions.
We report here on progress towards the realization of an atomic frequency standard using a fountain of laser cooled cesium atoms. We have recently observed Ramsey fringes on the 9.2 GHz clock transition and have begun preliminary work aimed at characterizing our fountain. This paper describes briefly the apparatus, discusses our current work and near-term directions. We conclude with a brief discussion of a laser system being built to realize two-dimensional Raman cooling or Raman velocity selection for cooling below the single photon recoil limit. This system will be used either in our fountain or in a cold-atom clock to be flown on the International Space Station.
Abstract : The grant as in support of a research program to explore the possibility of a microwave atomic clock based on an atomic fountain of cesium atoms. During the two year granting period, the following work was done: A large magneto-optic trap in a vapor cell was constructed where over 4x 10(exp 10) atoms were trapped at a density on the order of 10(exp 11) atoms/cu cm. This work increased the number of atoms optically trapped by a factor of -400 compared to previous work. The optical density of the atoms in this trap has a peak attenuation of e(-175). In an invited review article we examined the prospects for slow atom frequency standards. Most of the systematic effects that limit the current accuracy today's frequency standards decrease as the velocity of the atoms is reduced. We identified the one possible exception: collisions between ultra-cold atom in an atomic fountain could induce a phase shift that would ultimately limit the accuracy of the fountain clock. We brought the problem to the attention of B. Verhaar, who began a series of calculations on the effects of low energy collisions. jg p.4