Infrared, Millimeter-Wave, and Terahertz Technologies

Characterization of the kinetic inductance fraction of NbTiN MKIDs

Wei-Tao Lv, Qing Shi, Jing Li, Zheng Wang, Sheng‐Cai Shi

Published Oct 8, 2021• 0 citations
Publisher

Abstract

Microwave Kinetic Inductance Detectors (MKIDs), with high sensitivity and relatively simple frequency multiplexing, are emerging as a kind of large-array detectors in the terahertz (THz) band. An MKID, like a superconducting resonator, is composed of a planar capacitor and inductor that are made from superconducting films. The energy gap of the superconducting film for the planar inductor (at least part of it) is lower than the energy of photons to be detected. The kinetic inductance of the superconducting film irradiated by the photons is increased, shifting the resonance frequency toward a lower frequency. The frequency shift is proportional to the kinetic inductance fraction, i.e., the ratio of the kinetic inductance to the total inductance of the planar superconducting inductor. In this paper, we thoroughly investigate the kinetic inductance fraction for lumped-element and antenna-coupled MKIDs, which are both made from NbTiN. The detailed simulation, calculation, and measurement results will be presented.

DOI
10.1117/12.2602233

Related papers

Characterization of distributed and lumped-element THz MKIDs

Wei-Tao Lv, Liang-si Zhou, Jing Li +2 more

Microwave Kinetic Inductance Detectors (MKIDs), just like a planar resonance cavity resonating at a microwave frequency, are emerging as a kind of high-sensitivity detector suitable for large format arrays at terahertz (THz) wavelengths. There are two types of MKIDs, namely distributed (or antenna-coupled) MKIDs and lumped-element MKIDs (aka LeKIDs). Various superconducting thin films (such as Al, TiN, NbTiN, NbN, and Nb) have been investigated for MKIDs. They do work so long as the detected photon energy exceeds their energy gap, but their response and noise behaviors are yet to be fully understood. Here we report on the design, fabrication, and characterization of distributed and lumped-element MKIDs made of NbTiN superconducting film. Detailed simulation and measurement results will be presented.

•Nov 24, 2021•0 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations

Antenna-coupled Microwave Kinetic Inductance detectors (MKIDs) for mm and submm imaging arrays

Anastasios Vayonakis, James A. Schlaerth, S. Kumar +9 more

We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.

Softwaretechnik-Trends•Apr 1, 2008•3 citations

Design and Fabrication of Microwave Kinetic Inductance Detectors using NbN Symmetric Spiral Resonator Array

Kei Hayashi, Atsushi SAITO, Yasunobu Ogawa +9 more

We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.

Journal of Physics Conference Series•May 12, 2014•12 citations

Study of Superconducting Bilayer for Microwave Kinetic Inductance Detectors for Astrophysics

Agnès Dominjon, Masakazu Sekine, K. Karatsu +5 more

Due to their multiplexing capability and their good sensitivity to radiation from submillimeter to X-ray wavelengths, microwave kinetic inductance detectors (MKIDs) are increasingly used in the field of astrophysics. The Advanced Technology Center of the National Astronomical Observatory of Japan is developing MKIDs for astronomical observations such as CMB B-mode search with LiteBIRD. MKIDs are made of superconductors whose energy gap determines the detector frequency range. The energy gap depends on Tc, the critical temperature of the superconductor. It is thus important to be able to adjust Tc in order to choose the suitable frequency range. When using a single-layer MKID, the Tc is fixed by the superconducting gap energy of the unique component and cannot be changed. One possibility is to make a bilayer MKID using the proximity effect to adjust its critical temperature. This paper presents our new study on MKIDs made of superconductor/metal bilayers. We investigated niobium and copper bilayers (Nb/Cu) and fabricated different bilayers in our clean room. The critical temperature of each of them has been measured. We show that the Tc depends on the ratio between Nb and Cu thicknesses and that we are able to control it. Then, we characterized one of these Nb/Cu bilayers (Nb = 8 nm and Cu = 22 nm) once integrated in a MKID. We measured the temperature dependence of the resonant frequency, and we achieved quality factors as high as 2 × 104. The measurement of the noise spectrum provided a lower limit equal to -85 dBc/Hz, and the calculation of the noise equivalent power has shown that the sensitivity of the Nb/Cu bilayer MKID is not very far from that of an Al monolayer MKID.

IEEE Transactions on Applied Superconductivity•Feb 19, 2016•21 citations

Noise spectrum analysis of superconducting kinetic inductance detectors

Zhongyu Shi, Xucheng Dai, Haoyu Wang +10 more

As a newly developed pair-breaking superconducting detector, microwave kinetic inductance detectors are simple to integrate in the frequency domain and have already been used in astronomical detection and array imaging at the (sub)millimeter and optical wavelengths. For these applications, the dark noise level of kinetic inductance detector is one of the key performance indicators. Herein a noise power spectrum analysis method is introduced in detail, which can accurately and effectively analyze the noise spectrum of kinetic inductance detector in a wide frequency range. This method can well balance the noise spectrum resolution and variance performance, by taking the noise data at the resonance frequency with two sampling rates and setting the appropriate frequency resolutions for different frequency bands. This method is used to characterize and compare the noise of aluminum (Al) kinetic inductance detectors made from two different micromachining processes. We deposite a 25-nm-thick aluminum film on high-resistivity silicon substrate for one device, while place one silicon nitride (SiNx) film on the top and one on the bottom of the aluminum film for another device. It is found that the frequency noise of the device with two silicon nitride films is about 25% to 50% of the bare aluminum device. Using this double silicon nitride film fabrication technique, we further fabricate a few groups of lumped-element aluminum kinetic inductance detectors with various inductor and interdigitated capacitor designs. We investigate the noise properties of these devices at different microwave driven power and bath temperatures, and the experimental results show typical two-level system noise behaviors. Our work provides a standard method to characterize the noise power spectrum of kinetic inductor detector, and also paves the way to developing low-noise aluminum kinetic inductance detectors for terahertz imaging, photon-counting and energy-resolving applications.

Acta Physica Sinica•Nov 9, 2023•3 citations
Microwave Kinetic Inductance Detectors (MKIDs), with high sensitivity and relatively simple frequency multiplexing, are emerging as a kind of large-array detectors in the terahertz (THz) band. An MKID, like a superconducting resonator, is composed of a planar capacitor and inductor that are made from superconducting films. The energy gap of the superconducting film for the planar inductor (at least part of it) is lower than the energy of photons to be detected. The kinetic inductance of the superconducting film irradiated by the photons is increased, shifting the resonance frequency toward a lower frequency. The frequency shift is proportional to the kinetic inductance fraction, i.e., the ratio of the kinetic inductance to the total inductance of the planar superconducting inductor. In this paper, we thoroughly investigate the kinetic inductance fraction for lumped-element and antenna-coupled MKIDs, which are both made from NbTiN. The detailed simulation, calculation, and measurement results will be presented.
Microwave Kinetic Inductance Detectors (MKIDs), just like a planar resonance cavity resonating at a microwave frequency, are emerging as a kind of high-sensitivity detector suitable for large format arrays at terahertz (THz) wavelengths. There are two types of MKIDs, namely distributed (or antenna-coupled) MKIDs and lumped-element MKIDs (aka LeKIDs). Various superconducting thin films (such as Al, TiN, NbTiN, NbN, and Nb) have been investigated for MKIDs. They do work so long as the detected photon energy exceeds their energy gap, but their response and noise behaviors are yet to be fully understood. Here we report on the design, fabrication, and characterization of distributed and lumped-element MKIDs made of NbTiN superconducting film. Detailed simulation and measurement results will be presented.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.
We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.
Due to their multiplexing capability and their good sensitivity to radiation from submillimeter to X-ray wavelengths, microwave kinetic inductance detectors (MKIDs) are increasingly used in the field of astrophysics. The Advanced Technology Center of the National Astronomical Observatory of Japan is developing MKIDs for astronomical observations such as CMB B-mode search with LiteBIRD. MKIDs are made of superconductors whose energy gap determines the detector frequency range. The energy gap depends on Tc, the critical temperature of the superconductor. It is thus important to be able to adjust Tc in order to choose the suitable frequency range. When using a single-layer MKID, the Tc is fixed by the superconducting gap energy of the unique component and cannot be changed. One possibility is to make a bilayer MKID using the proximity effect to adjust its critical temperature. This paper presents our new study on MKIDs made of superconductor/metal bilayers. We investigated niobium and copper bilayers (Nb/Cu) and fabricated different bilayers in our clean room. The critical temperature of each of them has been measured. We show that the Tc depends on the ratio between Nb and Cu thicknesses and that we are able to control it. Then, we characterized one of these Nb/Cu bilayers (Nb = 8 nm and Cu = 22 nm) once integrated in a MKID. We measured the temperature dependence of the resonant frequency, and we achieved quality factors as high as 2 × 104. The measurement of the noise spectrum provided a lower limit equal to -85 dBc/Hz, and the calculation of the noise equivalent power has shown that the sensitivity of the Nb/Cu bilayer MKID is not very far from that of an Al monolayer MKID.
As a newly developed pair-breaking superconducting detector, microwave kinetic inductance detectors are simple to integrate in the frequency domain and have already been used in astronomical detection and array imaging at the (sub)millimeter and optical wavelengths. For these applications, the dark noise level of kinetic inductance detector is one of the key performance indicators. Herein a noise power spectrum analysis method is introduced in detail, which can accurately and effectively analyze the noise spectrum of kinetic inductance detector in a wide frequency range. This method can well balance the noise spectrum resolution and variance performance, by taking the noise data at the resonance frequency with two sampling rates and setting the appropriate frequency resolutions for different frequency bands. This method is used to characterize and compare the noise of aluminum (Al) kinetic inductance detectors made from two different micromachining processes. We deposite a 25-nm-thick aluminum film on high-resistivity silicon substrate for one device, while place one silicon nitride (SiNx) film on the top and one on the bottom of the aluminum film for another device. It is found that the frequency noise of the device with two silicon nitride films is about 25% to 50% of the bare aluminum device. Using this double silicon nitride film fabrication technique, we further fabricate a few groups of lumped-element aluminum kinetic inductance detectors with various inductor and interdigitated capacitor designs. We investigate the noise properties of these devices at different microwave driven power and bath temperatures, and the experimental results show typical two-level system noise behaviors. Our work provides a standard method to characterize the noise power spectrum of kinetic inductor detector, and also paves the way to developing low-noise aluminum kinetic inductance detectors for terahertz imaging, photon-counting and energy-resolving applications.