Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Characterization of distributed and lumped-element THz MKIDs

Wei-Tao Lv, Liang-si Zhou, Jing Li, Zheng Wang, Sheng‐Cai Shi

Published Nov 24, 2021• 0 citations
Publisher

Abstract

Microwave Kinetic Inductance Detectors (MKIDs), just like a planar resonance cavity resonating at a microwave frequency, are emerging as a kind of high-sensitivity detector suitable for large format arrays at terahertz (THz) wavelengths. There are two types of MKIDs, namely distributed (or antenna-coupled) MKIDs and lumped-element MKIDs (aka LeKIDs). Various superconducting thin films (such as Al, TiN, NbTiN, NbN, and Nb) have been investigated for MKIDs. They do work so long as the detected photon energy exceeds their energy gap, but their response and noise behaviors are yet to be fully understood. Here we report on the design, fabrication, and characterization of distributed and lumped-element MKIDs made of NbTiN superconducting film. Detailed simulation and measurement results will be presented.

DOI
10.1117/12.2605370

Related papers

Characterization of the kinetic inductance fraction of NbTiN MKIDs

Wei-Tao Lv, Qing Shi, Jing Li +2 more

Microwave Kinetic Inductance Detectors (MKIDs), with high sensitivity and relatively simple frequency multiplexing, are emerging as a kind of large-array detectors in the terahertz (THz) band. An MKID, like a superconducting resonator, is composed of a planar capacitor and inductor that are made from superconducting films. The energy gap of the superconducting film for the planar inductor (at least part of it) is lower than the energy of photons to be detected. The kinetic inductance of the superconducting film irradiated by the photons is increased, shifting the resonance frequency toward a lower frequency. The frequency shift is proportional to the kinetic inductance fraction, i.e., the ratio of the kinetic inductance to the total inductance of the planar superconducting inductor. In this paper, we thoroughly investigate the kinetic inductance fraction for lumped-element and antenna-coupled MKIDs, which are both made from NbTiN. The detailed simulation, calculation, and measurement results will be presented.

Infrared, Millimeter-Wave, and Terahertz Technologies•Oct 8, 2021•0 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations

Antenna-coupled Microwave Kinetic Inductance detectors (MKIDs) for mm and submm imaging arrays

Anastasios Vayonakis, James A. Schlaerth, S. Kumar +9 more

We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.

Softwaretechnik-Trends•Apr 1, 2008•1 citation

A Lumped Element Kinetic Inductance device for detection of THz radiation

Simon M. Doyle, Philip D. Mauskopf, C. Dunscombe +2 more

Kinetic inductance detectors (KIDs) provide a promising solution to the problem of producing large format arrays of ultra sensitive detectors for astronomy. Traditionally KIDs have been constructed from superconducting quarter-wavelength or half-wavelength resonator elements capacitively coupled to a co-planar feed line. Photons are detected by measuring the change in quasi-particle density caused by the splitting of Cooper pairs in the superconducting resonant element. This change in quasi-particle density alters the kinetic inductance, and hence the resonant frequency of the resonant element. This arrangement requires the quasi-particles generated by photon absorption to be concentrated at positions of high current density in the resonator. This is usually achieved through antenna coupling or quasi-particle trapping. For these detectors to work at wavelengths shorter than around 500 mum where antenna coupling can introduce a significant loss of efficiency, then a direct absorption method needs to be considered [3]. One solution to this problem is the Lumped Element KID (LEKID), which shows no current variation along its length and can be arranged into a photon absorbing area coupled to free space and therefore requiring no antennas or quasi-particle trapping. This paper outlines the basic concept of the LEKID, along with theoretical performance and experimental data for these devices.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2007•6 citations

Analysis and Performance of Lumped-Element Kinetic Inductance Detectors for W-Band

B. Aja, Marina C. de Ory, Luisa de la Fuente +5 more

Lumped-element superconducting resonators are a promising technology for their use in millimeter-wave observations and quantum computing applications that require large arrays of extremely sensitive detectors. Among them, lumped-element kinetic inductance detectors (LEKIDs) have shown good performance in the submillimeter band in several earth-based telescopes. In this work, LEKIDs for their use as millimeter-wave receivers of astronomical applications are presented. LEKID arrays using a thin bilayer of superconducting titanium/aluminum (Ti/Al), deposited on the silicon substrate, have been designed and fabricated. The design of a dual-polarization LEKID with the goal of detection at the W-band for two orthogonal polarizations is described and a fabricated array has demonstrated absorption at ambient temperature. Also, an approximate design methodology of the coupling parameter for LEKIDs' readout, essential for dynamic range optimization of the detector under millimeter-wave radiation, is proposed. In addition, the resonance characteristics and coupling factor of the fabricated superconducting resonators using high-quality internal factor Qiunder cryogenic temperatures have been analyzed. The design guidelines in this work are applicable to other LEKID arrays, and the presented superconducting Ti/Al thin-film LEKIDs can be used in future receiver arrays in the millimeter bands.

IEEE Transactions on Microwave Theory and Techniques•Dec 3, 2020•10 citations

Design and Fabrication of Microwave Kinetic Inductance Detectors using NbN Symmetric Spiral Resonator Array

Kei Hayashi, Atsushi SAITO, Yasunobu Ogawa +9 more

We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.

Journal of Physics Conference Series•May 12, 2014•9 citations
Microwave Kinetic Inductance Detectors (MKIDs), just like a planar resonance cavity resonating at a microwave frequency, are emerging as a kind of high-sensitivity detector suitable for large format arrays at terahertz (THz) wavelengths. There are two types of MKIDs, namely distributed (or antenna-coupled) MKIDs and lumped-element MKIDs (aka LeKIDs). Various superconducting thin films (such as Al, TiN, NbTiN, NbN, and Nb) have been investigated for MKIDs. They do work so long as the detected photon energy exceeds their energy gap, but their response and noise behaviors are yet to be fully understood. Here we report on the design, fabrication, and characterization of distributed and lumped-element MKIDs made of NbTiN superconducting film. Detailed simulation and measurement results will be presented.
Microwave Kinetic Inductance Detectors (MKIDs), with high sensitivity and relatively simple frequency multiplexing, are emerging as a kind of large-array detectors in the terahertz (THz) band. An MKID, like a superconducting resonator, is composed of a planar capacitor and inductor that are made from superconducting films. The energy gap of the superconducting film for the planar inductor (at least part of it) is lower than the energy of photons to be detected. The kinetic inductance of the superconducting film irradiated by the photons is increased, shifting the resonance frequency toward a lower frequency. The frequency shift is proportional to the kinetic inductance fraction, i.e., the ratio of the kinetic inductance to the total inductance of the planar superconducting inductor. In this paper, we thoroughly investigate the kinetic inductance fraction for lumped-element and antenna-coupled MKIDs, which are both made from NbTiN. The detailed simulation, calculation, and measurement results will be presented.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
We present results from completely lithographic antenna-coupled Microwave Kinetic Inductance detectors (MKIDs). MKIDs are superconducting resonators with resonant frequency and quality-factor which are highly sensitive to changes in the density of the quasiparticle population which occurs when photons above the superconducting gap energy are absorbed. The resonators are coupled to submm light through on-chip phased-array slot antennas. Each planar antenna consists of an array of N long slots which are fed along their length at M points. The resulting N*M feed points are combined in-phase using a binary summing tree made of low-loss superconducting microstrip lines. Due to its large size, the resulting planar antenna produces a narrow beam pattern and can therefore be used without additional optical coupling elements such as feedhorns or substrate lenses. The output of the antenna is a single superconducting thin-film microstrip line which can be efficiently coupled to one (or more) kinetic inductance coplanar waveguide resonators to produce a single (or multi-color) pixel in an imaging focal plane array, using in-line lumped element lithographic band-pass filters. Such highly integrated architectures can be easily fabricated on a single substrate, and many detectors can be frequency multiplexed through coupling to a single feedline. Microwave readout provides a lot of bandwidth per detector, allowing a large number of pixels to be read using a single cryogenic microwave amplifier and warm readout electronics.
Kinetic inductance detectors (KIDs) provide a promising solution to the problem of producing large format arrays of ultra sensitive detectors for astronomy. Traditionally KIDs have been constructed from superconducting quarter-wavelength or half-wavelength resonator elements capacitively coupled to a co-planar feed line. Photons are detected by measuring the change in quasi-particle density caused by the splitting of Cooper pairs in the superconducting resonant element. This change in quasi-particle density alters the kinetic inductance, and hence the resonant frequency of the resonant element. This arrangement requires the quasi-particles generated by photon absorption to be concentrated at positions of high current density in the resonator. This is usually achieved through antenna coupling or quasi-particle trapping. For these detectors to work at wavelengths shorter than around 500 mum where antenna coupling can introduce a significant loss of efficiency, then a direct absorption method needs to be considered [3]. One solution to this problem is the Lumped Element KID (LEKID), which shows no current variation along its length and can be arranged into a photon absorbing area coupled to free space and therefore requiring no antennas or quasi-particle trapping. This paper outlines the basic concept of the LEKID, along with theoretical performance and experimental data for these devices.
Lumped-element superconducting resonators are a promising technology for their use in millimeter-wave observations and quantum computing applications that require large arrays of extremely sensitive detectors. Among them, lumped-element kinetic inductance detectors (LEKIDs) have shown good performance in the submillimeter band in several earth-based telescopes. In this work, LEKIDs for their use as millimeter-wave receivers of astronomical applications are presented. LEKID arrays using a thin bilayer of superconducting titanium/aluminum (Ti/Al), deposited on the silicon substrate, have been designed and fabricated. The design of a dual-polarization LEKID with the goal of detection at the W-band for two orthogonal polarizations is described and a fabricated array has demonstrated absorption at ambient temperature. Also, an approximate design methodology of the coupling parameter for LEKIDs' readout, essential for dynamic range optimization of the detector under millimeter-wave radiation, is proposed. In addition, the resonance characteristics and coupling factor of the fabricated superconducting resonators using high-quality internal factor Qiunder cryogenic temperatures have been analyzed. The design guidelines in this work are applicable to other LEKID arrays, and the presented superconducting Ti/Al thin-film LEKIDs can be used in future receiver arrays in the millimeter bands.
We designed and fabricated a microwave kinetic inductance detector (MKID) using a niobium nitride (NbN) symmetric spiral resonator array. Previously we revealed that a rewound spiral structure works as not only a high-Q half-wavelength resonator but also as a broadband terahertz antenna. We conducted simulations for a 9 resonator array assuming NbN as the superconducting material and sapphire as the dielectric substrate, and obtained a maximum attenuation of over 30 dB and unloaded quality factors of over 2 × 10 5 for frequencies between 4.4 and 4.9 GHz. We fabricated the 9 resonator array MKID using NbN thin film deposited on an m-sapphire substrate by using dc magnetron sputtering. We observed half-wavelength resonances of around 4.5 GHz at 4 K. We measured the optical response of the MKID. The frequency shift was 0.5 MHz when illuminated with 650 nm photons.