Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Chip-Scale Atomic Clock - Coherent Population Trapping Vs. Conventional Interrogation

Robert Lutwak, Donald A. Emmons, W. J. Riley, R. Michael Garvey

Published Dec 5, 2002• 52 citations
OpenAlex

Abstract

Symmetricom-TRC has undertaken a development effort to produce a prototype chip-scale atomic clock "CSAC". The overall architecture of the CSAC and, in particular, the physics package, must be defined early in the project, prior to the onset of a large-scale engineering effort. Within the constraints imposed by the performance goals of the project, we have recognized two possible schemes for interrogating the ground-state hyperfine frequency of the gaseous atomic ensemble: the conventional double-resonance technique and the coherent population trapping technique. In this paper, we describe a laboratory apparatus, which allows for in situ comparison of the two techniques, without the ambiguities associated with comparing data from disparate experiments. Data are presented comparing the short-term stability resultant of the two techniques, as well as environmental sensitivity to resonance cell temperature, laser intensity, and RF power.

Related papers

The Chip-Scale Atomic Clock - Low-Power Physics Package

Robert Lutwak, Jinyi Deng, William Riley +7 more

We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.

•Dec 1, 2004•64 citations

The Chip-Scale Atomic Clock - Recent Development Progress

Robert Lutwak, Donald A. Emmons, Thomas C. English +1 more

We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.

•Sep 1, 2004•55 citations

Review of chip-scale atomic clocks based on coherent population trapping

Zhong Wang

Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.

Chinese Physics B•Mar 1, 2014•36 citations

Experimental study of the application feasibility of a novel chip-scale atomic clock scheme

Huifang Lin, Yuan Tian, Jie‐Hua Chen +1 more

Rb vapor cell with differential detection. Elliptically polarized light is used to interact with alkali atoms to generate coherent population trapping (CPT) resonance, and the CPT signal is obtained by detecting the Faraday rotation effect with differential detection technology. To move closer to an actual chip-scale atomic clock (CSAC), we reduce the volume of the experimental apparatus and use a divergent laser beam to interact with the atoms. We obtain the short-term frequency stability of the CSAC based on the differential detection scheme and compare it with that of a conventional CSAC. The results show that the frequency stability is more than two times better than that of current commercial CSAC devices with the same power consumption and volume.

Review of Scientific Instruments•May 1, 2019•6 citations

Study on characteristics of coherent population trapping spectral line for chip-scale atomic clock

Yi Yin, Yi Zhang, Tan Bo-Zhong +2 more

To Obtain an appropriate coherent population trapping (CPT) signal through a miniature atomic vapor cell is one of the key steps to implement a chip-scale atomic clock (CSAC). In the present experiment, the high S/N differential CPT spectral line has been achieved with a miniature atomic vapor cell through modulating the laser and extracting 87Rb atom laser interacting signal using the phase sensitive demodulation technique. With the spectral line, the dependence of CPT signal on the working parameters and the dependence of frequency stability of CSAC on the quality of the CPT signal have been studied; the obtained experimental results agree well with the theoretical prediction, which can be used as the recommended working parameters for CSAC. The methods exploited in the experiment can be implemented in the resource of a CSAC, therefore this experiment explores for CSAC the practical approaches of performance optimization.

Acta Physica Sinica•Jan 1, 2015•1 citation

Feasibility toward a compact high performance coherent population trapping clock

Peter Yun, François Tricot, Emeric de Clercq +4 more

We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.

•Apr 14, 2019•0 citations
Symmetricom-TRC has undertaken a development effort to produce a prototype chip-scale atomic clock "CSAC". The overall architecture of the CSAC and, in particular, the physics package, must be defined early in the project, prior to the onset of a large-scale engineering effort. Within the constraints imposed by the performance goals of the project, we have recognized two possible schemes for interrogating the ground-state hyperfine frequency of the gaseous atomic ensemble: the conventional double-resonance technique and the coherent population trapping technique. In this paper, we describe a laboratory apparatus, which allows for in situ comparison of the two techniques, without the ambiguities associated with comparing data from disparate experiments. Data are presented comparing the short-term stability resultant of the two techniques, as well as environmental sensitivity to resonance cell temperature, laser intensity, and RF power.
We have undertaken a development effort to produce a prototype chip-scale atomic clock (CSAC). The design goals include short-term stability, with a total power consumption of less than 30 mW and overall device volume <1 cubic cm. The stringent power requirement dominates the physics package architecture, necessarily dictating a small volume gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002 and PTTI 2003, we reported on laboratory experiments that underlie the fundamental architecture of our CSAC, based on interrogation of the cesium D1 transition by the technique of coherent population trapping (CPT). In the past year, the development effort has shifted from fundamental research and feasibility investigation to engineering and prototype development. In this paper, we report on the design of a rugged and compact physics package that is expected to exceed the ultimate performance and power requirements of the CSAC.
We have undertaken the development of a chip-scale atomic clock (CSAC) whose design goals include short-term stability, sigma(sub y)(tau=1 hour), of 1x10(exp 11) with a total power consumption of 30 mW and an overall device volume of 1 cu cm. The stringent power requirement dominates the physics package architecture, dictating a small (<5 mm(exp 3) gaseous atomic ensemble interrogated by a low-power semiconductor laser. At PTTI 2002, we reported on initial experimental investigations leading to the decision to employ the coherent population trapping (CPT) interrogation technique. This paper describes our further progress on the CSAC effort, including the development of custom vertical cavity surface emitting laser (VCSEL) sources and techniques for microfabricating miniature cesium vapor cells comprised of anodically bonded silicon and glass. Measurements of the signal contrast and linewidth of both the cesium D1 and D2 resonance transitions are compared, and frequency stability measurements of the CSAC testbed are presented.
Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.
Rb vapor cell with differential detection. Elliptically polarized light is used to interact with alkali atoms to generate coherent population trapping (CPT) resonance, and the CPT signal is obtained by detecting the Faraday rotation effect with differential detection technology. To move closer to an actual chip-scale atomic clock (CSAC), we reduce the volume of the experimental apparatus and use a divergent laser beam to interact with the atoms. We obtain the short-term frequency stability of the CSAC based on the differential detection scheme and compare it with that of a conventional CSAC. The results show that the frequency stability is more than two times better than that of current commercial CSAC devices with the same power consumption and volume.
To Obtain an appropriate coherent population trapping (CPT) signal through a miniature atomic vapor cell is one of the key steps to implement a chip-scale atomic clock (CSAC). In the present experiment, the high S/N differential CPT spectral line has been achieved with a miniature atomic vapor cell through modulating the laser and extracting 87Rb atom laser interacting signal using the phase sensitive demodulation technique. With the spectral line, the dependence of CPT signal on the working parameters and the dependence of frequency stability of CSAC on the quality of the CPT signal have been studied; the obtained experimental results agree well with the theoretical prediction, which can be used as the recommended working parameters for CSAC. The methods exploited in the experiment can be implemented in the resource of a CSAC, therefore this experiment explores for CSAC the practical approaches of performance optimization.
We demonstrate a vapor-cell atomic-clock prototype based on a continuous-wave interrogation and double-modulation coherent population trapping (DM-CPT) technique. The DM-CPT technique uses a synchronous modulation of polarization and the relative phase of a bichromatic laser beam in order to increase the number of atoms trapped in a dark state, i.e., a nonabsorbing state. The narrow resonance, observed in the transmission of a Cs vapor cell, is used as a narrow frequency discriminator in an atomic clock. A detailed characterization of the CPT resonance versus numerous parameters is reported. A short-term fractional-frequency stability of 3.2×10−13τ−1/2 up to a 100-s averaging time is measured. These performances are more than one order of magnitude better than industrial Rb clocks and are comparable to those of the best laboratory-prototype vapor-cell clocks. The noise-budget analysis shows that the short- and midterm frequency stability is mainly limited by the power fluctuations of the microwave used to generate the bichromatic laser. These preliminary results demonstrate that the DM-CPT technique is well suited for the development of a high-performance atomic clock, with the potential compact and robust setup due to its linear architecture. This clock could find future applications in industry, telecommunications, instrumentation, or global navigation satellite systems.