Acta Physica Sinica

Study on characteristics of coherent population trapping spectral line for chip-scale atomic clock

Yi Yin, Yi Zhang, Tan Bo-Zhong, Jie‐Hua Chen, Sihong Gu

Published Jan 1, 2015• 1 citation
Publisher

Abstract

To Obtain an appropriate coherent population trapping (CPT) signal through a miniature atomic vapor cell is one of the key steps to implement a chip-scale atomic clock (CSAC). In the present experiment, the high S/N differential CPT spectral line has been achieved with a miniature atomic vapor cell through modulating the laser and extracting 87Rb atom laser interacting signal using the phase sensitive demodulation technique. With the spectral line, the dependence of CPT signal on the working parameters and the dependence of frequency stability of CSAC on the quality of the CPT signal have been studied; the obtained experimental results agree well with the theoretical prediction, which can be used as the recommended working parameters for CSAC. The methods exploited in the experiment can be implemented in the resource of a CSAC, therefore this experiment explores for CSAC the practical approaches of performance optimization.

DOI
10.7498/aps.64.034207

Related papers

Review of chip-scale atomic clocks based on coherent population trapping

Zhong Wang

Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.

Chinese Physics B•Mar 1, 2014•39 citations

Experimental study of the application feasibility of a novel chip-scale atomic clock scheme

Huifang Lin, Yuan Tian, Jie‐Hua Chen +1 more

Rb vapor cell with differential detection. Elliptically polarized light is used to interact with alkali atoms to generate coherent population trapping (CPT) resonance, and the CPT signal is obtained by detecting the Faraday rotation effect with differential detection technology. To move closer to an actual chip-scale atomic clock (CSAC), we reduce the volume of the experimental apparatus and use a divergent laser beam to interact with the atoms. We obtain the short-term frequency stability of the CSAC based on the differential detection scheme and compare it with that of a conventional CSAC. The results show that the frequency stability is more than two times better than that of current commercial CSAC devices with the same power consumption and volume.

Review of Scientific Instruments•May 1, 2019•6 citations

Narrow linewidth CPT signal in small vapor cells for chip scale atomic clocks

Miao Zhu, Leonard S. Cutler, J.E. Berberian +3 more

We report our measurement of coherent-population-trapping (CPT) signal linewidths in small vapor cells, which are desirable for chip scale atomic clock (CSAC) applications. The linewidths are measured in both rubidium vapor cells and cesium vapor cells. Using a micro-machined silicon absorption cell (diameter = 1.7 mm, length = 2 mm), we demonstrate a sub-kHz linewidth (FWHM) of the clock transition in the /sup 133/Cs atom (|F = 3, m/sub F/ = 0>/spl harr/|F = 4, m/sub F/ = 0>). The measured intrinsic linewidths (FWHM = 777 Hz for Cs and FWHM = 1496 Hz for Rb) of the cells agree with the calculated results.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 12, 2005•7 citations

Stabilization method for atomic clocks to detect the maximum coherent-population-trapping resonance signal

Yusuke Odagiri, Satoshi Hatano, Yuichiro Yano +3 more

Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.

Japanese Journal of Applied Physics•Jun 1, 2025•2 citations

Microfabricated cells for chip-scale atomic clock based on coherent population trapping: Fabrication and investigation

Ермак Сергей Викторович, V. V. Semenov, Пятышев Евгений Нилович +5 more

A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.

St Petersburg Polytechnical University Journal Physics and Mathematics•Mar 1, 2015•10 citations

Coherent population trapping resonances in Cs–Ne vapor microcells for miniature clocks applications

Rodolphe Boudot, P. Dziuban, Madoka Hasegawa +4 more

We report the characterization of dark line resonances observed in Cs vapor microcells filled with a unique neon (Ne) buffer gas. The impact on the coherent population trapping (CPT) resonance of some critical external parameters such as laser intensity, cell temperature, and microwave power is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77–80 °C range for various Ne buffer gas pressures. The necessity to adjust the Ne buffer gas pressure or the cell dimensions to optimize the CPT signal height at the frequency inversion temperature is pointed out. Based on such Cs–Ne microcells, we preliminary demonstrate a 852 nm vertical cavity surface emitted laser (VCSEL)-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ)=1.5×10−10τ−1/2 until 30 s. These results, similar to those published in the literature by others groups, prove the potential of our original microcell technology in view of the development of high-performance chip scale atomic clocks.

Journal of Applied Physics•Jan 1, 2011•66 citations
To Obtain an appropriate coherent population trapping (CPT) signal through a miniature atomic vapor cell is one of the key steps to implement a chip-scale atomic clock (CSAC). In the present experiment, the high S/N differential CPT spectral line has been achieved with a miniature atomic vapor cell through modulating the laser and extracting 87Rb atom laser interacting signal using the phase sensitive demodulation technique. With the spectral line, the dependence of CPT signal on the working parameters and the dependence of frequency stability of CSAC on the quality of the CPT signal have been studied; the obtained experimental results agree well with the theoretical prediction, which can be used as the recommended working parameters for CSAC. The methods exploited in the experiment can be implemented in the resource of a CSAC, therefore this experiment explores for CSAC the practical approaches of performance optimization.
Research on chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) is reviewed. The background and the inspiration for the research are described, including the important schemes proposed to improve the CPT signal quality, the selection of atoms and buffer gases, and the development of micro-cell fabrication. With regard to the reliability, stability, and service life of the CSACs, the research regarding the sensitivity of the CPT resonance to temperature and laser power changes is also reviewed, as well as the CPT resonance's collision and light of frequency shifts. The first generation CSACs have already been developed but its characters are still far from our expectations. Our conclusion is that miniaturization and power reduction are the most important aspects calling for further research.
Rb vapor cell with differential detection. Elliptically polarized light is used to interact with alkali atoms to generate coherent population trapping (CPT) resonance, and the CPT signal is obtained by detecting the Faraday rotation effect with differential detection technology. To move closer to an actual chip-scale atomic clock (CSAC), we reduce the volume of the experimental apparatus and use a divergent laser beam to interact with the atoms. We obtain the short-term frequency stability of the CSAC based on the differential detection scheme and compare it with that of a conventional CSAC. The results show that the frequency stability is more than two times better than that of current commercial CSAC devices with the same power consumption and volume.
We report our measurement of coherent-population-trapping (CPT) signal linewidths in small vapor cells, which are desirable for chip scale atomic clock (CSAC) applications. The linewidths are measured in both rubidium vapor cells and cesium vapor cells. Using a micro-machined silicon absorption cell (diameter = 1.7 mm, length = 2 mm), we demonstrate a sub-kHz linewidth (FWHM) of the clock transition in the /sup 133/Cs atom (|F = 3, m/sub F/ = 0>/spl harr/|F = 4, m/sub F/ = 0>). The measured intrinsic linewidths (FWHM = 777 Hz for Cs and FWHM = 1496 Hz for Rb) of the cells agree with the calculated results.
Chip-scale atomic clocks based on coherent population trapping (CPT) face challenges due to miniaturized gas cells, which reduces the CPT resonance signal and the absorption signals of alkali atoms. To overcome this, we propose a method that simultaneously stabilizes the laser wavelength and microwave modulation frequency without relying on absorption line detection. Our approach enables stabilization at the point where the amplitude of the CPT resonance signal is maximized, making it suitable for compact atomic clocks. The system uses three lock-in amplifiers: one is used to stabilize the RF modulation frequency, and the other two are used for detecting the amplitude of the CPT resonance and stabilizing the laser wavelength. The Allan deviation measurements demonstrate a 1.4-fold improvement in short-term stability compared to conventional methods, suggesting that the proposed technique is a promising solution for enhancing the performance of small gas-cell atomic clocks.
A universal method for fabrication of miniature cells for frequency standards and quantum magnetometers containing 87Rb atoms in the atmosphere of inert gas neon based on integrated technologies is considered. The results of experimental studies of coherent population trapping signals observed for a series of cells which provided recovery of vapors of an alkali metal from the rubidium dichromate salt with the help of laser radiation are presented. The coherent population trapping signals with a typical linewidth of 2–3 kHz and a signal-to-noise ratio of 1500 in the 1-Hz bandwidth were observed, which allows one to provide a relative frequency stability of atomic clock of 10−11 at 100 s.
We report the characterization of dark line resonances observed in Cs vapor microcells filled with a unique neon (Ne) buffer gas. The impact on the coherent population trapping (CPT) resonance of some critical external parameters such as laser intensity, cell temperature, and microwave power is studied. We show the suppression of the first-order light shift by proper choice of the microwave power. The temperature dependence of the Cs ground state hyperfine resonance frequency is shown to be canceled in the 77–80 °C range for various Ne buffer gas pressures. The necessity to adjust the Ne buffer gas pressure or the cell dimensions to optimize the CPT signal height at the frequency inversion temperature is pointed out. Based on such Cs–Ne microcells, we preliminary demonstrate a 852 nm vertical cavity surface emitted laser (VCSEL)-modulated based CPT atomic clock exhibiting a short term fractional frequency instability σy(τ)=1.5×10−10τ−1/2 until 30 s. These results, similar to those published in the literature by others groups, prove the potential of our original microcell technology in view of the development of high-performance chip scale atomic clocks.