Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI

Maximizing dynamic range of microwave kinetic inductance detectors through high-speed tone tracking

Jonathan R. Hoh, Adrian K. Sinclair, Ryan Stephenson

Published Dec 12, 2020• 1 citation
Publisher

Abstract

Microwave kinetic inductance detectors (MKIDs) operate through means of a superconducting resonator that changes resonant frequency and quality factor when incident photons are absorbed in the superconducting material. Incident power on MKIDs is determined by reading out the phase and amplitude of a tone injected into each detector. However, if the incident power on an MKID changes too drastically and the resonant frequency moves too far from the probe tone, amplitude information becomes useless and the detector is effectively out of commission until a VNA sweep is used to relocate resonances. Here we present the designs and preliminary results of a tone-tracking firmware that uses phase information to maintain an on-resonance probe tone at all times, removing the need for time-intensive VNA sweeps during observations and effectively maximizing the dynamic range of MKIDs. We will conclude with a discussion on future NASA missions that hope implement this tone-tracking design.

DOI
10.1117/12.2559899

Related papers

Tunable responsivity and bandwidth in microwave kinetic inductance detectors via readout current nonlinearity

M. Rouble, Peter Day, Matt Dobbs +3 more

Microwave kinetic inductance detectors (MKIDs) are generally read out with microwave readout tones of high enough amplitude to adequately suppress the noise contribution of the first-stage amplifier. At high readout power, the detector's resonant frequency is altered as a result of the dependence of the kinetic inductance on the internally circulating microwave current. With the tone placed below the resonant frequency, the nonlinear frequency shift results in a positive feedback effect that can significantly enhance the responsivity of the detector, to both optical and microwave power. We report a factor of 10 enhancement in optical response by tuning the readout power and frequency to close to the resonator's bifurcation point. A corresponding decrease in the bandwidth of the resonator is observed under these conditions. We show that the strength of the feedback effect can be easily selected by adjusting the excitation, and provide a map of possible operational states to do so. Operation of MKIDs in this mode could be used to improve sensitivity when non-intrinsic noise sources are significant.

arXiv:2607.09178•Jul 10, 2026•0 citations

Design and measurement of superconducting microwave kinetic inductance detectors

Florian Blauth

Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.

•Oct 1, 2019•0 citations

Towards a Low-Cost Readout System for Arrays of Cryogenic Detectors

K. J. Ramos, Horacio Arnaldi, L. Tosi

A microwave kinetic inductance detector (MKID) is a superconducting pair-breaking detector used for astronomical observations in the sub-millimeter through visible range. Radiation is detected as a phase and amplitude signal proportional to the frequency shift of the device. In the case of arrays of MKIDs, the read-out is performed using the frequency division multiplexing technique. However, there is currently no commercial system or low-cost standard electronics available for this task. In this work, we take the first steps towards developing a low-cost readout system for MKIDs based on the Red Pitaya board. We have developed a firmware for the efficient generation of probe tones, and show figures of merit characterizing the performance of the readout in a hardware prototype. The design is flexible, letting us to adapt it to new frequencies and amplitudes requirements of the MKID arrays.

Argentine Conference on Electronics (CAE)•Mar 9, 2023•1 citation

Calibration Scheme for Large Kinetic Inductance Detector Arrays Based on Readout Frequency Response

Laura Bisigello, S. J. C. Yates, Vignesh Murugesan +2 more

Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.

arXiv:1602.00442•Journal of Low Temperature Physics•Feb 9, 2016•14 citations

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

Edward J. Wollack, Kongpop U-yen, Thomas R. Stevenson +3 more

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

•Dec 1, 2013•0 citations

A measurement method for responsivity of microwave kinetic inductance detector by changing power of readout microwaves

Hiroki Kutsuma, M. Hattori, Ryo Koyano +5 more

Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of the cutting-edge superconducting detectors. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase responses as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285 mK. We also confirm the consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.

arXiv:1907.03403•Applied Physics Letters•Jul 15, 2019•5 citations
Microwave kinetic inductance detectors (MKIDs) operate through means of a superconducting resonator that changes resonant frequency and quality factor when incident photons are absorbed in the superconducting material. Incident power on MKIDs is determined by reading out the phase and amplitude of a tone injected into each detector. However, if the incident power on an MKID changes too drastically and the resonant frequency moves too far from the probe tone, amplitude information becomes useless and the detector is effectively out of commission until a VNA sweep is used to relocate resonances. Here we present the designs and preliminary results of a tone-tracking firmware that uses phase information to maintain an on-resonance probe tone at all times, removing the need for time-intensive VNA sweeps during observations and effectively maximizing the dynamic range of MKIDs. We will conclude with a discussion on future NASA missions that hope implement this tone-tracking design.
Microwave kinetic inductance detectors (MKIDs) are generally read out with microwave readout tones of high enough amplitude to adequately suppress the noise contribution of the first-stage amplifier. At high readout power, the detector's resonant frequency is altered as a result of the dependence of the kinetic inductance on the internally circulating microwave current. With the tone placed below the resonant frequency, the nonlinear frequency shift results in a positive feedback effect that can significantly enhance the responsivity of the detector, to both optical and microwave power. We report a factor of 10 enhancement in optical response by tuning the readout power and frequency to close to the resonator's bifurcation point. A corresponding decrease in the bandwidth of the resonator is observed under these conditions. We show that the strength of the feedback effect can be easily selected by adjusting the excitation, and provide a map of possible operational states to do so. Operation of MKIDs in this mode could be used to improve sensitivity when non-intrinsic noise sources are significant.
Microwave kinetic inductance detectors (MKID) are superconducting broadband direct detectors. If a superconducting thin film patterned into a resonator is illuminated with photons, Cooper pairs break up and the kinetic inductance of the film changes. This shifts the resonance frequency downwards and the dissipation of the resonator increases, which can be detected in the phase and amplitude of a transmitted signal. \n \nIn this thesis, a waveguide coupled MKID is designed and simulated. 350 GHz radiation is coupled into a copper waveguide via a horn antenna. A waveguide probe leads the signal onto a 9 µm silicon membrane where it is absorbed in a 40 nm superconducting aluminum film which is the inductive part of a superconducting resonator. The capacitor of the resonator is made of niobium. Two versions of the device are developed, a transmission line resonator and a lumped element resonator design. The new design will enable an accurate understanding of the optical sensitivity of MKIDs and allow comparison of different resonator materials. Since two different resonator types are used, the direct comparison of transmission line and lumped resonators will also be possible. \n \nA measurement setup is developed including an ADR cryostat to cool MKID devices down to below 40 mK. An analog readout system using either a vector network analyzer or an IQ mixer is designed and built. The necessary software to control the ADR, the temperature monitoring, the readout signal generation and detection and the signal acquisition of the setup is also developed. \n \nThe waveguide coupled MKID design is fabricated in our in-house microfabrication laboratory and measured in the new setup. In my measurements, the devices do not show a resonance feature. The VNA and DC measurements are analyzed to determine a plausible hypothesis of the failure. The devices are diagnosed for critical issues during fabrication which will be addressed in a future iteration. \n \nTo verify the measurement setup, a test device of the IRAM NIKA 2 MKID camera is measured and the complete analysis pipeline is exercised. The quasi-particle lifetime in the aluminum thin films is measured and a dark and optical noise equivalent power are determined. The results are within the uncertainty comparable to measurements of IRAM themselves. \n \nA test chip designed in my master thesis that contains eight NbTiN resonators is measured in the new setup and non-linear effects under strong readout power are studied. Parametric amplification and oscillation of a resonator are shown qualitatively.
A microwave kinetic inductance detector (MKID) is a superconducting pair-breaking detector used for astronomical observations in the sub-millimeter through visible range. Radiation is detected as a phase and amplitude signal proportional to the frequency shift of the device. In the case of arrays of MKIDs, the read-out is performed using the frequency division multiplexing technique. However, there is currently no commercial system or low-cost standard electronics available for this task. In this work, we take the first steps towards developing a low-cost readout system for MKIDs based on the Red Pitaya board. We have developed a firmware for the efficient generation of probe tones, and show figures of merit characterizing the performance of the readout in a hardware prototype. The design is flexible, letting us to adapt it to new frequencies and amplitudes requirements of the MKID arrays.
Microwave kinetic inductance detector (MKID) provides a way to build large ground-based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over a wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that the shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousands of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.
A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.
Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of the cutting-edge superconducting detectors. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase responses as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285 mK. We also confirm the consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.