The paper presents the measurements results of the orientational light shift of the radio-optical 0-0 resonance frequency in the rubidium vapor with isotopic pumping. The experiments were done on a laboratory quantum discriminator, the functional diagram of which contained a known element set for rubidium frequency standard on a gas cell. The discriminator was placed in the three identical pairs of Helmholtz coils, 50 cm in diameter, which created a working magnetic field (10 μT, 3 μT, and 1 μT) in the area of the gas cell. Helmholtz coils were connected to alternating voltage sources to create a rotating magnetic field relative to the normal to the direction of the pumping light. To weaken external magnetic noise and inhomogeneities of the laboratory magnetic field, the entire system was placed in a magnetic shield with a screening factor of ~ 103, which practically made it possible to exclude the effect of the residual field on the measurements accuracy. The main experimental results are formulated as follows: the orientational frequency shift of the 0-0 radio-optical resonance does not depend on the magnitude of the working magnetic field and is linearly related to the pumping light intensity; when the working magnetic field is oriented normal to the quantum discriminator optical axis, the tensor and scalar components of the light shift have equal (positive) signs, which at any temperature of the filter-cell leads to their impossible compensation; when the working magnetic field is oriented along the quantum discriminator optical axis, the tensor and scalar components of the light shift have opposite signs, which at the corresponding temperature of the filter-cell leads to their possible (partial) compensation.

DOI
10.1109/eexpolytech50912.2020.9243991

Related papers

Orientational frequency shifts of microwave 0-0 superfine resonance in 87Rb vapor with selective optical pumping

A. A. Baranov, Ермак Сергей Викторович, V. V. Semenov

The orientational frequency shift of the UHF radio-optical resonance in the 87 Rb vapor with a selective optical pumping by laser and lamp sources is studied experimentally and theoretically. A leading role of the tensor component of the light shift is noticed for both excitation modes, and a modulation technique of the resonance frequency orientation shift suppression is demonstrated. We show that it is necessary to ensure a constancy of the angle between the pump light direction and the external magnetic field vector when using a rubidium quantum discriminator based on moving and rotating carriers.

Optics and Spectroscopy•Mar 1, 2013•5 citations

The Influence of the Magnetic Field Inhomogeneity on the Orientational Light Frequency Shift in Rubidium Clock

Ермак Сергей Викторович, V. V. Semenov

In this work, the influence of the operating magnetic field gradient on the frequency of the 0-0-transition of a lamp-pumped rubidium atomic clock was investigated. As a gas cell, we used a cell with an antirelaxation coating of the walls and containing Rb87 atoms. Experimental dependences of the atomic clock model resonance frequency on the applied magnetic field gradient in the range of 0.003 Oe / cm - 0.012 Oe / cm and in the magnetic fields range of 0.0135 Oe - 0.027 Oe were obtained. The orientation 0-0-resonance frequency shift having value more than value of the frequency shift due to the quadratic magnetic dependence of the 0-0-resonance frequency was measured.

International Conference on Electrical Engineering and Photonics (EExPolytech)•Oct 14, 2021•2 citations

The orientation dependence of the SHF radio-optical resonance frequency light shift in rubidium vapors

Alexey Baranov, Ермак Сергей Викторович, V. V. Semenov

The results of the theoretical and experimental research of the light and orientation frequency shift effects in laboratory scheme of the87Rb cell frequency standard are provided. The real orientation frequency shift importance is shown.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•7 citations

Double resonance fequency light shift compensation in optically oriented laser-pumped alkali atoms

A. A. Baranov, Ермак Сергей Викторович, E. A. Sagitov +2 more

The contributions of the vector and scalar components to the magnetically dependent microwave transition frequency light shift are analyzed and the compensation of these components is experimentally demonstrated for the 87Rb atoms optically oriented by a laser tuned to the D 2 line of the head doublet. The Allan variance is studied as a function of the averaging time for a tandem of optically pumped quantum magnetometers (OPQMs), one of which is based on a low-frequency spin oscillator while another is based on a quantum microwave discriminator with a resonance frequency that corresponds to magnetically dependent transitions between HFS sublevels with the extremal value of the magnetic quantum number. It is shown that the compensation of the scalar and vector components of the light shift in OPQMs reduces the Allan variance at averaging times that exceed hundreds of seconds compared to a quantum discriminator based on the magnetically independent 0–0 transition. In this case, the minimal Allan variance in OPQMs at the end resonance is achieved at considerably longer averaging times than in the case of the quantum discriminator that is tuned to the 0–0 transition frequency.

Journal of Experimental and Theoretical Physics•Sep 1, 2015•9 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•11 citations

Magnetometric sensitivity optimization for nonlinear optical rotation with frequency-modulated light: Rubidium D2 line

Derek F. Jackson Kimball, Louis Jacome, Srikanth Guttikonda +2 more

Atomic spin polarization of alkali atoms in the ground-state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise measurement of atomic spin precession and energy shifts of ground-state Zeeman sublevels. In the present work, nonlinear magneto-optical rotation with frequency-modulated light (FM NMOR) is used to measure magnetic field-induced spin precession for rubidium atoms contained in a paraffin-coated cell. The magnetometric sensitivity of FM NMOR for the rubidium D2 line is studied as a function of light power, detuning, frequency-modulation amplitude, and rubidium vapor density. For a 5-cm-diameter cell at temperature T≈35 °C, the optimal shot-noise-projected magnetometric sensitivity is found to be 2×10−11 G/Hz (corresponding to a sensitivity to spin precession frequency of ≈10 μHz/Hz or a sensitivity to Zeeman sublevel shifts of ≈4×10−20 eV/Hz).

arXiv:0906.3586•Journal of Applied Physics•Sep 15, 2009•32 citations
The paper presents the measurements results of the orientational light shift of the radio-optical 0-0 resonance frequency in the rubidium vapor with isotopic pumping. The experiments were done on a laboratory quantum discriminator, the functional diagram of which contained a known element set for rubidium frequency standard on a gas cell. The discriminator was placed in the three identical pairs of Helmholtz coils, 50 cm in diameter, which created a working magnetic field (10 μT, 3 μT, and 1 μT) in the area of the gas cell. Helmholtz coils were connected to alternating voltage sources to create a rotating magnetic field relative to the normal to the direction of the pumping light. To weaken external magnetic noise and inhomogeneities of the laboratory magnetic field, the entire system was placed in a magnetic shield with a screening factor of ~ 103, which practically made it possible to exclude the effect of the residual field on the measurements accuracy. The main experimental results are formulated as follows: the orientational frequency shift of the 0-0 radio-optical resonance does not depend on the magnitude of the working magnetic field and is linearly related to the pumping light intensity; when the working magnetic field is oriented normal to the quantum discriminator optical axis, the tensor and scalar components of the light shift have equal (positive) signs, which at any temperature of the filter-cell leads to their impossible compensation; when the working magnetic field is oriented along the quantum discriminator optical axis, the tensor and scalar components of the light shift have opposite signs, which at the corresponding temperature of the filter-cell leads to their possible (partial) compensation.
The orientational frequency shift of the UHF radio-optical resonance in the 87 Rb vapor with a selective optical pumping by laser and lamp sources is studied experimentally and theoretically. A leading role of the tensor component of the light shift is noticed for both excitation modes, and a modulation technique of the resonance frequency orientation shift suppression is demonstrated. We show that it is necessary to ensure a constancy of the angle between the pump light direction and the external magnetic field vector when using a rubidium quantum discriminator based on moving and rotating carriers.
In this work, the influence of the operating magnetic field gradient on the frequency of the 0-0-transition of a lamp-pumped rubidium atomic clock was investigated. As a gas cell, we used a cell with an antirelaxation coating of the walls and containing Rb87 atoms. Experimental dependences of the atomic clock model resonance frequency on the applied magnetic field gradient in the range of 0.003 Oe / cm - 0.012 Oe / cm and in the magnetic fields range of 0.0135 Oe - 0.027 Oe were obtained. The orientation 0-0-resonance frequency shift having value more than value of the frequency shift due to the quadratic magnetic dependence of the 0-0-resonance frequency was measured.
The contributions of the vector and scalar components to the magnetically dependent microwave transition frequency light shift are analyzed and the compensation of these components is experimentally demonstrated for the 87Rb atoms optically oriented by a laser tuned to the D 2 line of the head doublet. The Allan variance is studied as a function of the averaging time for a tandem of optically pumped quantum magnetometers (OPQMs), one of which is based on a low-frequency spin oscillator while another is based on a quantum microwave discriminator with a resonance frequency that corresponds to magnetically dependent transitions between HFS sublevels with the extremal value of the magnetic quantum number. It is shown that the compensation of the scalar and vector components of the light shift in OPQMs reduces the Allan variance at averaging times that exceed hundreds of seconds compared to a quantum discriminator based on the magnetically independent 0–0 transition. In this case, the minimal Allan variance in OPQMs at the end resonance is achieved at considerably longer averaging times than in the case of the quantum discriminator that is tuned to the 0–0 transition frequency.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
Atomic spin polarization of alkali atoms in the ground-state can survive thousands of collisions with paraffin-coated cell walls. The resulting long spin-relaxation times achieved in evacuated, paraffin-coated cells enable precise measurement of atomic spin precession and energy shifts of ground-state Zeeman sublevels. In the present work, nonlinear magneto-optical rotation with frequency-modulated light (FM NMOR) is used to measure magnetic field-induced spin precession for rubidium atoms contained in a paraffin-coated cell. The magnetometric sensitivity of FM NMOR for the rubidium D2 line is studied as a function of light power, detuning, frequency-modulation amplitude, and rubidium vapor density. For a 5-cm-diameter cell at temperature T≈35 °C, the optimal shot-noise-projected magnetometric sensitivity is found to be 2×10−11 G/Hz (corresponding to a sensitivity to spin precession frequency of ≈10 μHz/Hz or a sensitivity to Zeeman sublevel shifts of ≈4×10−20 eV/Hz).