Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Sciences

Response of a Cold-Electron Bolometer on THz Radiation from a Long YBa2Cu3O7−δ Bicrystal Josephson Junction

A. L. Pankratov, Leonid Revin, Anna V. Gordeeva, Dmitry V. Masterov, Alexey E. Parafin, V. O. Zbrozhek, L. S. Kuzmin

Published Oct 29, 2020• 7 citations
Publisher

Abstract

The response of the Cold-Electron Bolometers (CEBs), integrated into a 2-D array of dipole antennas, has been measured by irradiation from YBa2Cu3O7−δ (YBCO) 50 μm long Josephson junction into the THz region at frequencies from 0.1 to 0.8 THz. The possibility of controlling the amplitude-frequency characteristic is demonstrated by the external magnetic field in the traveling wave regime of a long Josephson junction. The YBCO junction has been formed on the bicrystal Zr1−xYxO2 (YSZ) substrate by magnetron sputtering and etching of the film. CEBs have been fabricated using an Al multilayer structure by a self-aligned shadow evaporation technique on Si substrate. Both receiver and oscillator have been located inside the same cryostat at 0.3 K and 2.7 K plates, respectively.

DOI
10.3390/app10217667

Related papers

A Bunch of YBCO Josephson Generators for the Analysis of Resonant Cold-Electron Bolometers

L. S. Revin, Dmitry V. Masterov, Alexey E. Parafin +8 more

The resonant properties of Cold-Electron Bolometers (CEBs) located at a 0.3 K cryostat plate are measured using a 50 μm long high-temperature YBa2Cu3O7−δ (YBCO) Josephson junction oscillator, placed on a 2.7 K plate of the same cryostat. For these purposes, a bunch of YBCO Josephson oscillators with various lengths of dipole antennas and overlapping generation bands has been developed and investigated in 50–500 GHz frequency range. Two setups of Josephson junction placement were compared, and as a result, various narrow-band receiving systems with CEBs have been measured, demonstrating the feasibility of the presented approach.

Applied Sciences•Nov 23, 2022•5 citations

Terahertz transmission spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, Evgueni Stepantsov +4 more

For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 8, 2004•3 citations

THz Spectrometer Based on a Josephson Oscillator and a Cold-Electron Bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +3 more

We have demonstrated a low temperature spectrometer operating in a wide range of frequencies from 100 GHz to 1.8 THz. The spectrometer has utilized unique properties of high-T c superconducting Josephson junctions and wideband response of sensitive Cold-Electron 13olometers (CEB). The voltage response of the CEB integrated with log-periodic and double-dipole antennas, has been measured using an oscillator consisting of high-T c Josephson junction integrated on separate substrate with a log-periodic antenna. The response of the bolometer with a double dipole antenna has resonance shape with maximum corresponding to the designed central frequency of 300 GHz. A voltage response of the bolometer up to 4 . 10 V/W corresponds to a technical noise equivalent power of the bolometer of 1.2 . 10 W/HZ 112 including bolometer and amplifier sources of noise. A high-T c Josephson junction operated at temperatures below 2 K shows advantages of high I cRii product that enhances the oscillation frequency to over 1.8 THz. The resolution of the spectrometer is determined by the linewidth of Josephson oscillations and for this temperature is of the order of 1 GHz.

Softwaretechnik-Trends•Jan 1, 2004•0 citations

Terahertz spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, T. Claeson +2 more

For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.

•Jan 1, 2004•0 citations

Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +5 more

The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .

Journal of Experimental and Theoretical Physics Letters•Mar 1, 2004•10 citations

Terahertz response for bicrystal YBCO Josephson junctions

Kensuke Nakajima, Jian Chen, Hiroaki Myoren +2 more

The high-frequency response of bicrystal YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// Josephson junctions for far infrared laser irradiation is presented. The junctions on silicon and MgO substrates exhibit a remarkable first order Shapiro step for the methanol line at 1.76 THz. dV/dI measurements reveal several steps corresponding to the methanol lines at 1.48, 1.76 and 2.53 THz. The line width of Josephson oscillation at these frequencies is estimated from the width of the Shapiro steps. It is suggested that the excess shot noise broadens the line width.

IEEE Transactions on Applied Superconductivity•Jun 1, 1997•24 citations
The response of the Cold-Electron Bolometers (CEBs), integrated into a 2-D array of dipole antennas, has been measured by irradiation from YBa2Cu3O7−δ (YBCO) 50 μm long Josephson junction into the THz region at frequencies from 0.1 to 0.8 THz. The possibility of controlling the amplitude-frequency characteristic is demonstrated by the external magnetic field in the traveling wave regime of a long Josephson junction. The YBCO junction has been formed on the bicrystal Zr1−xYxO2 (YSZ) substrate by magnetron sputtering and etching of the film. CEBs have been fabricated using an Al multilayer structure by a self-aligned shadow evaporation technique on Si substrate. Both receiver and oscillator have been located inside the same cryostat at 0.3 K and 2.7 K plates, respectively.
The resonant properties of Cold-Electron Bolometers (CEBs) located at a 0.3 K cryostat plate are measured using a 50 μm long high-temperature YBa2Cu3O7−δ (YBCO) Josephson junction oscillator, placed on a 2.7 K plate of the same cryostat. For these purposes, a bunch of YBCO Josephson oscillators with various lengths of dipole antennas and overlapping generation bands has been developed and investigated in 50–500 GHz frequency range. Two setups of Josephson junction placement were compared, and as a result, various narrow-band receiving systems with CEBs have been measured, demonstrating the feasibility of the presented approach.
For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.
We have demonstrated a low temperature spectrometer operating in a wide range of frequencies from 100 GHz to 1.8 THz. The spectrometer has utilized unique properties of high-T c superconducting Josephson junctions and wideband response of sensitive Cold-Electron 13olometers (CEB). The voltage response of the CEB integrated with log-periodic and double-dipole antennas, has been measured using an oscillator consisting of high-T c Josephson junction integrated on separate substrate with a log-periodic antenna. The response of the bolometer with a double dipole antenna has resonance shape with maximum corresponding to the designed central frequency of 300 GHz. A voltage response of the bolometer up to 4 . 10 V/W corresponds to a technical noise equivalent power of the bolometer of 1.2 . 10 W/HZ 112 including bolometer and amplifier sources of noise. A high-T c Josephson junction operated at temperatures below 2 K shows advantages of high I cRii product that enhances the oscillation frequency to over 1.8 THz. The resolution of the spectrometer is determined by the linewidth of Josephson oscillations and for this temperature is of the order of 1 GHz.
For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.
The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .
The high-frequency response of bicrystal YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// Josephson junctions for far infrared laser irradiation is presented. The junctions on silicon and MgO substrates exhibit a remarkable first order Shapiro step for the methanol line at 1.76 THz. dV/dI measurements reveal several steps corresponding to the methanol lines at 1.48, 1.76 and 2.53 THz. The line width of Josephson oscillation at these frequencies is estimated from the width of the Shapiro steps. It is suggested that the excess shot noise broadens the line width.