Terahertz spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, T. Claeson, Е. А. Степанцов, Ian Jasper Agulo

Published Jan 1, 2004• 0 citations
OpenAlex

Abstract

For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.

Related papers

Terahertz transmission spectroscopy by Josephson oscillator and cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin, Evgueni Stepantsov +4 more

For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 8, 2004•3 citations

THz Spectrometer Based on a Josephson Oscillator and a Cold-Electron Bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +3 more

We have demonstrated a low temperature spectrometer operating in a wide range of frequencies from 100 GHz to 1.8 THz. The spectrometer has utilized unique properties of high-T c superconducting Josephson junctions and wideband response of sensitive Cold-Electron 13olometers (CEB). The voltage response of the CEB integrated with log-periodic and double-dipole antennas, has been measured using an oscillator consisting of high-T c Josephson junction integrated on separate substrate with a log-periodic antenna. The response of the bolometer with a double dipole antenna has resonance shape with maximum corresponding to the designed central frequency of 300 GHz. A voltage response of the bolometer up to 4 . 10 V/W corresponds to a technical noise equivalent power of the bolometer of 1.2 . 10 W/HZ 112 including bolometer and amplifier sources of noise. A high-T c Josephson junction operated at temperatures below 2 K shows advantages of high I cRii product that enhances the oscillation frequency to over 1.8 THz. The resolution of the spectrometer is determined by the linewidth of Josephson oscillations and for this temperature is of the order of 1 GHz.

Softwaretechnik-Trends•Jan 1, 2004•0 citations

Terahertz spectroscopy with a Josephson oscillator and a SINIS bolometer

Michael A. Tarasov, L. S. Kuzmin, Е. А. Степанцов +5 more

The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .

Journal of Experimental and Theoretical Physics Letters•Mar 1, 2004•10 citations

Terahertz (THz) direct detectors based on superconducting HEBs with thermal, THz and microwave biasing methods (Conference Presentation)

Jian Chen

Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.

Next-Generation Spectroscopic Technologies•May 14, 2019•0 citations

Terahertz high-sensitivity superconducting detectors

Shi Sheng-Cai, Jing Li, Wen Zhang +1 more

The terahertz regime, as a last radio window, remains to be fully explored, and astronomical and atmospheric observations in this regime are scientifically important. Like other frequency regimes, developing high-sensitivity detectors (coherent and incoherent) is of particular significance for both ground-based and space-borne facilities. As the coherent detector of choice below 1.4 THz, superconductor-insulator-superconductor (SIS) heterodyne mixers have achieved as high a sensitivity as five times the quantum limit around 1.4 THz. It is, however, still a challenge to developing SIS mixers at frequencies beyond 1.4 THz with considerable transmission loss in superconducting circuits due to the Cooper-pair breaking by energetic photons and increased many difficulties in designing and fabricating. So far, superconducting hot electron bolometer (HEB) mixers have been the most sensitive heterodyne detectors at frequencies above 1.5 THz, and successfully used to detect molecular spectral lines up to 2.5 THz from ground-based and space telescopes. Although spiral-antenna coupled NbN HEB mixers show a good sensitivity in the whole THz frequency range, the directly measured spectral response with Fourier transform spectrometer falls quickly as frequency increases, especially above 3 THz. The terahertz band is also of particular importance to observe astronomical objects such as cosmic microwave background, early distant objects, cold objects and dusty objects. Aiming at such objects, we develop a terahertz imaging array system by combining advanced superconducting detectors such as transition edge sensor (TES) and microwave kinetic inductance detectors (MKIDs), thus the system has a frequency band centred at 350 m, an operational temperature of 0.3 K, and a sensitivity reaching background limit performance for ground-based applications. In addition, it is expected to have some breakthroughs in ultra-sensitive superconducting TES and MKID, low noise multi-channel readout and multiplexing, efficient terahertz-wave coupling technology, and large-scale array system integration. The developed terahertz imaging array system will serve as the next-generation instrument of Dome A 5 m terahertz telescope, conducting a 350 m-band legacy survey for studying the planets, stars, galaxies and cosmology. Besides the application in astronomy, the developed terahertz imaging array system can also be applied to some areas requiring rapid detection such as security, deep space exploration, and biomedical imaging. In this paper, we mainly introduce the superconducting detectors developed at Purple Mountain Observatory and those for international collaborative projects.

Acta Physica Sinica•Jan 1, 2015•8 citations

Concept of a mixer based on a cold-electron bolometer

Michael A. Tarasov, L. S. Kuzmin

A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.

Journal of Experimental and Theoretical Physics Letters•May 1, 2005•7 citations
For sensitive wideband spectroscopy at THz frequencies with performance better than for Fourier Transform Spectrometer, one needs a wide-range electrically tunable, narrow linewidth THz source, and a sensitive broadband detector. To obtain a low noise level of sensor we use a superconducting normal metal cold electron bolometer (CEB). A voltage response of the bolometer is 4.108 V/W and an amplifier-limited technical noise equivalent power of the bolometer is 1.25.10-17 W/Hz1/2. The wide band electrically tuned terahertz band cryogenic oscillator is a Josephson junction. Contrary to conventional Josephson junctions based on niobium, and naturally limited in frequency by energy gap of about 700 GHz, the high critical temperature YBaCuO junctions can extend this limit by an order of magnitude. At 4 K such oscillators can radiate at frequencies exceeding 2 THz. Signals received by bolometers integrated with double-dipole and log-periodic antennas and irradiated by the Josephson oscillator show in our experiments the high frequency response corresponding to an oscillation frequency of up to 1.75 THz. Such cryogenic terahertz network analyzer is suitable for low-signal spectral evaluation of cryogenic detectors, quasioptical sub-mm cryogenic filters, planar antennas with planar microwave filters, integrated structures comprising such elements, and arrays of cryogenic receivers.
For sensitive wideband spectroscopy at TeraHertz frequencies one needs a wide-range electrically tunable THz source and a sensitive detector. In this paper a superconducting normal metal cold electron bolometer (CEB) was used as a broadband sensor. Bolometers were integrated with broadband log-periodic antenna designed for 0.2-2 THz frequency range and double-dipole antennas designed for 300 and 600 GHz central frequency. A Josephson junction was used as a wide band electrically tuned terahertz cryogenic oscillator. Bicrystal YBaCuO Josephson junctions demonstrated a characteristic voltage IcRn of over 4 mV that corresponds to characteristic frequency about 2 THz. The bolometer chip is attached to a Si substrate lens at 260 mK and the oscillator chip is attached to the sapphire substrate lens at 1.8 K, with lenses facing each other at the distance of few centimeters. High signal was measured in the whole frequency range up to 1.7 THz by simple changing the bias voltage of Josephson junction from zero to 3.5 mV. A voltage response of the bolometer up to 4*108 V/W corresponds to an amplifier-limited technical noise equivalent power of the bolometer NEP=1.25*10-17 W/Hz1/2. Combining a Terahertz band Josephson junction, a high-sensitive hot electron bolometer, and a sample under test in between, makes it possible to develop a cryogenic compact Terahertz-band transmission spectrometer with a resolution below 1 GHz corresponding to the linewidth of Josephson oscillations. For frequencies below 600 GHz a conventional Nb shunted SIS junction can be used as Josephson oscillator.
We have demonstrated a low temperature spectrometer operating in a wide range of frequencies from 100 GHz to 1.8 THz. The spectrometer has utilized unique properties of high-T c superconducting Josephson junctions and wideband response of sensitive Cold-Electron 13olometers (CEB). The voltage response of the CEB integrated with log-periodic and double-dipole antennas, has been measured using an oscillator consisting of high-T c Josephson junction integrated on separate substrate with a log-periodic antenna. The response of the bolometer with a double dipole antenna has resonance shape with maximum corresponding to the designed central frequency of 300 GHz. A voltage response of the bolometer up to 4 . 10 V/W corresponds to a technical noise equivalent power of the bolometer of 1.2 . 10 W/HZ 112 including bolometer and amplifier sources of noise. A high-T c Josephson junction operated at temperatures below 2 K shows advantages of high I cRii product that enhances the oscillation frequency to over 1.8 THz. The resolution of the spectrometer is determined by the linewidth of Josephson oscillations and for this temperature is of the order of 1 GHz.
The voltage response of a thin-film normal-metal hot-electron bolometer based on a SINIS (superconductor-insulator-normal metal-insulator-superconductor) structure to the radiation of a high-temperature Josephson junction in the terahertz frequency region was measured. Bolometers were integrated with planar log-periodic and double-dipole antennas, and Josephson junctions were integrated with log-periodic antennas. Measurements showed that the Josephson junction at a temperature of 260 mK was overheated by the transport current, so that its electron temperature exceeded 3 K at a bias voltage of 1 mV. The maximum response of a bolometer with a double-dipole antenna was observed at a frequency of 300 GHz, which agreed well with the calculated value. The Josephson radiation was observed at frequencies up to 1.7 THz. The voltage response of a bolometer reached 4×10 8 V/W, and the total noise-equivalent power reached 1.5×10 −17 W/Hz 1/2 .
Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.
The terahertz regime, as a last radio window, remains to be fully explored, and astronomical and atmospheric observations in this regime are scientifically important. Like other frequency regimes, developing high-sensitivity detectors (coherent and incoherent) is of particular significance for both ground-based and space-borne facilities. As the coherent detector of choice below 1.4 THz, superconductor-insulator-superconductor (SIS) heterodyne mixers have achieved as high a sensitivity as five times the quantum limit around 1.4 THz. It is, however, still a challenge to developing SIS mixers at frequencies beyond 1.4 THz with considerable transmission loss in superconducting circuits due to the Cooper-pair breaking by energetic photons and increased many difficulties in designing and fabricating. So far, superconducting hot electron bolometer (HEB) mixers have been the most sensitive heterodyne detectors at frequencies above 1.5 THz, and successfully used to detect molecular spectral lines up to 2.5 THz from ground-based and space telescopes. Although spiral-antenna coupled NbN HEB mixers show a good sensitivity in the whole THz frequency range, the directly measured spectral response with Fourier transform spectrometer falls quickly as frequency increases, especially above 3 THz. The terahertz band is also of particular importance to observe astronomical objects such as cosmic microwave background, early distant objects, cold objects and dusty objects. Aiming at such objects, we develop a terahertz imaging array system by combining advanced superconducting detectors such as transition edge sensor (TES) and microwave kinetic inductance detectors (MKIDs), thus the system has a frequency band centred at 350 m, an operational temperature of 0.3 K, and a sensitivity reaching background limit performance for ground-based applications. In addition, it is expected to have some breakthroughs in ultra-sensitive superconducting TES and MKID, low noise multi-channel readout and multiplexing, efficient terahertz-wave coupling technology, and large-scale array system integration. The developed terahertz imaging array system will serve as the next-generation instrument of Dome A 5 m terahertz telescope, conducting a 350 m-band legacy survey for studying the planets, stars, galaxies and cosmology. Besides the application in astronomy, the developed terahertz imaging array system can also be applied to some areas requiring rapid detection such as security, deep space exploration, and biomedical imaging. In this paper, we mainly introduce the superconducting detectors developed at Purple Mountain Observatory and those for international collaborative projects.
A phase-sensitive terahertz heterodyne mixer of a new type based on a cold-electron bolometer is proposed. In this mixer, a normal-metal thin-film absorber is connected to a planar antenna via superconductor-insulator-normal metal (SIN) tunnel junctions, thus forming a SINIS structure. The SINIS mixer combines the advantages of a hot-electron bolometer (HEB), such as a high signal frequency at a small local oscillator power, with the advantages of an SIS mixer, including low noise level, a high intermediate frequency, and wide working temperature range (up to a critical temperature of the superconductor). In contrast to the HEB and SIS mixers, the proposed device is less sensitive to external magnetic noise and exhibits no additional noise related to the superconducting transition and the Josephson effect.