Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Development of a Narrow-band Laser Interferometer using Resonant Sideband Extraction

O. Miyakawa, K. Kuroda, Gerhard Heinzel, S. Kawamura

Published Jan 1, 2000• 0 citations
OpenAlex

Related papers

A power recycled Michelson interferometer with resonant sideband extraction

M. Gray

AIP conference proceedings•Jan 1, 2000•2 citations

Raman sideband cooling of a Ba+138 ion using a Zeeman interval

Christopher M. Seck, Mark Kokish, Matthew Dietrich +1 more

Motional ground state cooling and internal state preparation are important elements for quantum logic spectroscopy (QLS), a class of quantum information processing. Since QLS does not require the high gate fidelities usually associated with quantum computation and quantum simulation, it is possible to make simplifying choices in ion species and quantum protocols at the expense of some fidelity. Here, we report sideband cooling and motional state detection protocols for $^{138}\mathrm{Ba}^{+}$ of sufficient fidelity for QLS without an extremely narrow-band laser or the use of a species with hyperfine structure. We use the two ${S}_{1/2}$ Zeeman sublevels of $^{138}\mathrm{Ba}^{+}$ to Raman sideband cool a single ion to the motional ground state. Because of the small Zeeman splitting, continuous near-resonant Raman sideband cooling of $^{138}\mathrm{Ba}^{+}$ requires only the Doppler cooling lasers and two additional acousto-optic modulators. Observing the near-resonant Raman optical pumping fluorescence, we extract relevant experimental parameters and demonstrate a final average motional quantum number $\overline{n}\ensuremath{\ll}1$. We additionally employ a second, far-off-resonant laser driving Raman $\ensuremath{\pi}$ pulses between the two Zeeman sublevels to provide motional state detection for QLS and to confirm the sideband cooling efficiency, measuring a final $\overline{n}=0.15(6)$.

arXiv:1603.09322•Physical Review A•May 17, 2016•9 citations

Readout of quantum devices with a sideband microwave interferometer immune to systematic noise

N. Crescini, Eoin G. Kelly, Gian Salis +1 more

The accuracy of microwave measurements is not only critical for applications in telecommunication and radar but also for future quantum computers. Qubit technologies such as superconducting qubits or spin qubits require the detection of minuscule signals, typically achieved by reflecting a microwave tone off a resonator that is coupled to the qubit. Noise from cabling and amplification, e.g., from temperature variations, can be detrimental to readout fidelity. We present an approach to detect phase and amplitude changes of a device under test based on the differential measurement of microwave tones generated by two first-order sidebands of a carrier signal. The two microwave tones are sent through the same cable to the measured device that exhibits a narrow-band response for one sideband and leaves the other unaffected. The reflected sidebands are interfered by down-conversion with the carrier. By choosing the amplitude and phases of the sidebands, suppression of either common-amplitude or common-phase noise can be achieved, allowing for fast, stable measurements of frequency shifts and quality factors of resonators. Test measurements were performed on $\mathrm{NbN}$ superconducting resonators at 25 mK to calibrate and characterize the experimental setup and to study time-dependent fluctuations of their resonance frequency.

arXiv:2303.07018•Physical Review Applied•Oct 27, 2023•0 citations

Resonant sideband extraction for detectors with Fabry-Perot arms

Gerhard Heinzel, J. Mizuno, Roland Schilling +3 more

•Jan 1, 1997•1 citation

Narrow saturated absorption resonances in the transmission band of an active interferometer

Sergei N Bagaev, A. A. Kurbatov, Е. А. Титов

The shape of the transmission band of an active interferometer, a resonator with amplification and absorption cells excited by an external signal, is studied. Upon tuning the external signal frequency, the narrow saturated absorption resonances can be observed in the transmission band of the interferometer. It is shown that, by varying the gain, the resonance absorption amplitude can be compensated for one order of smallness in pressure. The effect of amplitude and frequency noises of the external signal on the results obtained is studied.

Optics and Spectroscopy•Jan 1, 2000•4 citations

A new generation interferometer for fundamental and applied research

А. В. Ипатов

Uspekhi Fizicheskih Nauk•Jan 1, 2013•11 citations
Motional ground state cooling and internal state preparation are important elements for quantum logic spectroscopy (QLS), a class of quantum information processing. Since QLS does not require the high gate fidelities usually associated with quantum computation and quantum simulation, it is possible to make simplifying choices in ion species and quantum protocols at the expense of some fidelity. Here, we report sideband cooling and motional state detection protocols for 138Ba+^{138}\mathrm{Ba}^{+}138Ba+ of sufficient fidelity for QLS without an extremely narrow-band laser or the use of a species with hyperfine structure. We use the two S1/2{S}_{1/2}S1/2​ Zeeman sublevels of 138Ba+^{138}\mathrm{Ba}^{+}138Ba+ to Raman sideband cool a single ion to the motional ground state. Because of the small Zeeman splitting, continuous near-resonant Raman sideband cooling of 138Ba+^{138}\mathrm{Ba}^{+}138Ba+ requires only the Doppler cooling lasers and two additional acousto-optic modulators. Observing the near-resonant Raman optical pumping fluorescence, we extract relevant experimental parameters and demonstrate a final average motional quantum number $\overline{n}\ensuremath{\ll}1$. We additionally employ a second, far-off-resonant laser driving Raman $\ensuremath{\pi}$ pulses between the two Zeeman sublevels to provide motional state detection for QLS and to confirm the sideband cooling efficiency, measuring a final n‾=0.15(6)\overline{n}=0.15(6)n=0.15(6).
The accuracy of microwave measurements is not only critical for applications in telecommunication and radar but also for future quantum computers. Qubit technologies such as superconducting qubits or spin qubits require the detection of minuscule signals, typically achieved by reflecting a microwave tone off a resonator that is coupled to the qubit. Noise from cabling and amplification, e.g., from temperature variations, can be detrimental to readout fidelity. We present an approach to detect phase and amplitude changes of a device under test based on the differential measurement of microwave tones generated by two first-order sidebands of a carrier signal. The two microwave tones are sent through the same cable to the measured device that exhibits a narrow-band response for one sideband and leaves the other unaffected. The reflected sidebands are interfered by down-conversion with the carrier. By choosing the amplitude and phases of the sidebands, suppression of either common-amplitude or common-phase noise can be achieved, allowing for fast, stable measurements of frequency shifts and quality factors of resonators. Test measurements were performed on NbN\mathrm{NbN}NbN superconducting resonators at 25 mK to calibrate and characterize the experimental setup and to study time-dependent fluctuations of their resonance frequency.
The shape of the transmission band of an active interferometer, a resonator with amplification and absorption cells excited by an external signal, is studied. Upon tuning the external signal frequency, the narrow saturated absorption resonances can be observed in the transmission band of the interferometer. It is shown that, by varying the gain, the resonance absorption amplitude can be compensated for one order of smallness in pressure. The effect of amplitude and frequency noises of the external signal on the results obtained is studied.