Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Resonant sideband extraction for detectors with Fabry-Perot arms

Gerhard Heinzel, J. Mizuno, Roland Schilling, Walter Winkler, Albrecht Rüdiger, K. Danzmann

Published Jan 1, 1997• 1 citation
OpenAlex

Related papers

Low-frequency optical resonance in a multiple-beam Fabry-Perot interferometer

В. О. Гладышев, Andrey N. Morozov

Technical Physics Letters•Jul 1, 1993•7 citations

Pass-through Mach-Zehnder topologies for macroscopic quantum measurements

Farid Ya Khalili

Several relatively small-scale experimental setups, aimed on prototyping of future laser gravitational-wave detectors and testing of new methods of quantum measurements with macroscopic mechanical objects, are under development now. In these devices, not devoted directly to the gravitational-wave detection, Mach-Zehnder interferometer with pass-through Fabry-Perot cavities in the arms can be used instead of the standard Michelson/Fabry-Perot one. The advantage of this topology is that it does not contain high-reflectivity end mirrors with multilayer coatings, which Brownian noise could constitute the major part of the noise budget of the Michelson/Fabry-Perot interferometers. We consider here two variants of this topology: the ``ordinary'' position meter scheme, and a new variant of the quantum speed meter.

arXiv:1102.0385•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Jun 1, 2011•1 citation

Development of a Narrow-band Laser Interferometer using Resonant Sideband Extraction

O. Miyakawa, K. Kuroda, Gerhard Heinzel +1 more

•Jan 1, 2000•0 citations

Third-order photon cross-correlations in resonance fluorescence

Yamil Nieves, Andreas Müller

We investigated third-order correlations between photons from a single quantum dot's resonance fluorescence in the strong excitation regime originating from opposite sidebands of the power spectrum. The three-time correlation measurements for photons filtered using three independent Fabry-Perot etalons resulted in correlation maps with ``antibunching'' features as a consequence of correlations originating from the same sideband, and ``bunching ridges'' due to opposite sideband correlated photons.

Physical review. B./Physical review. B•Oct 19, 2020•8 citations

Nonlinear dynamics in a Fabry-Perot resonator

Luigi A. Lugiato, Lorenzo M. Narducci

The European Physical Journal B•Mar 1, 1988•42 citations

Superconducting microwave resonators for physics experiments

N. Klein, G. Müller, H. Piel +1 more

Superconducting resonators at K-band frequencies have been developed for different applications in general physics. Niobium pillbox cavities have been built for the one-atom maser experiment by which the interaction of Rydberg atoms with single microwave photons has been investigated. At 21.5 GHz and 1.3 K, quality factors of up to 10/sup 11/ were obtained. Coating of the cavity with Nb/sub 3/Sn resulted in quality factors of 6*10/sup 8/ at 4.2 K and 6*10/sup 9/ at 2 K. A superconducting Fabry-Perot resonator consisting of two spherically curved niobium mirrors was also investigated. The quality factor of 1.8*10/sup 7/ measured at 25 GHz and 4.2 K was found to be two orders of magnitude higher than for a corresponding copper resonator. Fabry-Perot resonators can be used for detecting small position changes for one mirror with respect to another caused by gravitational forces. First experiments with copper Fabry-Perot mirrors suspended in a vacuum chamber provided a maximum sensitivity for a gravitational acceleration of one mirror of 4*10/sup -11/ m/s/sup 2/. These results are promising for a possible fifth force detector based on a superconducting Fabry-Perot resonator.>

IEEE Transactions on Magnetics•Mar 1, 1989•8 citations
Several relatively small-scale experimental setups, aimed on prototyping of future laser gravitational-wave detectors and testing of new methods of quantum measurements with macroscopic mechanical objects, are under development now. In these devices, not devoted directly to the gravitational-wave detection, Mach-Zehnder interferometer with pass-through Fabry-Perot cavities in the arms can be used instead of the standard Michelson/Fabry-Perot one. The advantage of this topology is that it does not contain high-reflectivity end mirrors with multilayer coatings, which Brownian noise could constitute the major part of the noise budget of the Michelson/Fabry-Perot interferometers. We consider here two variants of this topology: the ``ordinary'' position meter scheme, and a new variant of the quantum speed meter.
We investigated third-order correlations between photons from a single quantum dot's resonance fluorescence in the strong excitation regime originating from opposite sidebands of the power spectrum. The three-time correlation measurements for photons filtered using three independent Fabry-Perot etalons resulted in correlation maps with ``antibunching'' features as a consequence of correlations originating from the same sideband, and ``bunching ridges'' due to opposite sideband correlated photons.
Superconducting resonators at K-band frequencies have been developed for different applications in general physics. Niobium pillbox cavities have been built for the one-atom maser experiment by which the interaction of Rydberg atoms with single microwave photons has been investigated. At 21.5 GHz and 1.3 K, quality factors of up to 10/sup 11/ were obtained. Coating of the cavity with Nb/sub 3/Sn resulted in quality factors of 6*10/sup 8/ at 4.2 K and 6*10/sup 9/ at 2 K. A superconducting Fabry-Perot resonator consisting of two spherically curved niobium mirrors was also investigated. The quality factor of 1.8*10/sup 7/ measured at 25 GHz and 4.2 K was found to be two orders of magnitude higher than for a corresponding copper resonator. Fabry-Perot resonators can be used for detecting small position changes for one mirror with respect to another caused by gravitational forces. First experiments with copper Fabry-Perot mirrors suspended in a vacuum chamber provided a maximum sensitivity for a gravitational acceleration of one mirror of 4*10/sup -11/ m/s/sup 2/. These results are promising for a possible fifth force detector based on a superconducting Fabry-Perot resonator.>