Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

AIP conference proceedings

A power recycled Michelson interferometer with resonant sideband extraction

M. Gray

Published Jan 1, 2000• 2 citations
Publisher
DOI
10.1063/1.1291856

Related papers

Development of a Narrow-band Laser Interferometer using Resonant Sideband Extraction

O. Miyakawa, K. Kuroda, Gerhard Heinzel +1 more

•Jan 1, 2000•0 citations

Funktionsweise eines Michelson-Interferometers

Ricardo Linke

Springer eBooks•Feb 8, 2017•0 citations

Several Problems in Michelson Interferometer and Its Interference

绍书 黄

Modern Physics•Jan 1, 2022•0 citations

One photon in an open box: The Michelson interferometer

Richard H. Lindsay, Donald Sprague

American Journal of Physics•May 1, 1985•0 citations

A Michelson Interferometer for ultracold neutrons

A. Steyerl, S. S. Malik, K. -A. Steinhauser +1 more

The European Physical Journal B•Jun 1, 1979•10 citations

Power-recycled Michelson interferometer with resonant sideband extraction

D. A. Shaddock, Malcolm B. Gray, Conor M Mow-Lowry +1 more

We present a system for the control and signal extraction of a power-recycled Michelson interferometer with resonant sideband extraction. This control system is capable of locking four degrees of freedom to a fixed point while locking the signal cavity to an arbitrary detuned point. One of the strengths of this system is that it can quickly change the instrument's frequency response without disrupting continuous operation. We report on an experimental implementation of this control system on a benchtop prototype and present broadband measurements of the prototype's frequency response for a range of signal cavity detunings.

Applied Optics•Mar 1, 2003•19 citations
We present a system for the control and signal extraction of a power-recycled Michelson interferometer with resonant sideband extraction. This control system is capable of locking four degrees of freedom to a fixed point while locking the signal cavity to an arbitrary detuned point. One of the strengths of this system is that it can quickly change the instrument's frequency response without disrupting continuous operation. We report on an experimental implementation of this control system on a benchtop prototype and present broadband measurements of the prototype's frequency response for a range of signal cavity detunings.