Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The European Physical Journal B

A Michelson Interferometer for ultracold neutrons

A. Steyerl, S. S. Malik, K. -A. Steinhauser, L. Berger

Published Jun 1, 1979• 10 citations
Publisher
DOI
10.1007/bf01320210

Related papers

Effect of Earth's Rotation on the Quantum Mechanical Phase of the Neutron

S. Werner, J.-L. Staudenmann, R. Colella

Using a neutron interferometer of the type first developed by Bonse and Hart for x rays, we have observed the effect of Earth's rotation on the phase of the neutron wave function. This experiment is the quantum mechanical analog of the optical interferometry observations of Michelson, Gale, and Pearson.

Physical Review Letters•Apr 23, 1979•461 citations

Possibility of Microscopy and Interferometry with Ultracold Neutrons

WORLD SCIENTIFIC eBooks•May 29, 2020•0 citations

Experiments with ultracold neutrons

L.V. Groshev, V.N. Dvoretskii, A.M. Demidov +5 more

Physics Letters B•Mar 1, 1971•49 citations

A Michelson Interferometer for Relative Phase Locking of Optical Beams

Guowei Li, Sheng-Jhe Huang, Hsu-Sheng Wu +4 more

A Michelson-type interferometer is built to dynamically lock the optical phase difference between the two-arm laser beams. The phase difference is tunable and allowed for continuous adjustments nearly by 160°. Under the best locking condition, a relative phase stability better than 0.1° is achieved starting from the original phase jitter of 10 to 15°. The interferometer is made by simply adding a pair of Brewster windows in one arm of the conventional setup, yet it provides much robust phase locking. It is readily applicable for optical lattice construction and nondestructive phase contrast imaging of ultracold atoms.

Journal of the Physical Society of Japan•Jan 25, 2008•8 citations

Phase sensitivity of a modified Grover-Michelson interferometer

Chaoping Wei, Chuting Xu, Qi Li

Power recycling techniques are usually used to improve the phase sensitivity of interferometers by reusing the input light energy, and can beat the shot noise level. Recent studies have demonstrated that the phase sensitivity of the interferometer is significantly improved via the addition of a recycling cavity, that is, coupling the interferometer with an external optical device. This study reviewed such types of interferometers named Grover-Michelson interferometers (GMI), and discusses their phase sensitivity with coherent states as inputs. Subsequently, a detailed comparison in terms of the scale of 1/ N and the standard quantum limit (SQL) is presented. The results demonstrate that the phase sensitivity of GMI improved owing to the power recycling and exceeded the value of 1/ N . Further, we proposed a modified Grover-Michelson interferometer (MGMI) with two input ports and examined its phase sensitivity with single photon or coherent states, respectively. Finally, in the presence of photon losses, we investigated the phase sensitivity of the four different interferometers, including MGMI, GMI, Mach-Zehnder interferometer (MZI), and SU(1,1) interferometer (SU(1,1)I), and conducted detailed comparisons. The results of this study indicated that the phase sensitivity of MGMI significantly improved owing to the increase in input energy, and MGMI exhibited the strongest robustness against photon number loss. These theoretical results are expected to facilitate improvements in interferometers and the detection of weak signals.

Optics Continuum•Jun 15, 2025•2 citations

Neutron Wave Optics Studied with Ultracold Neutrons

A. Steyerl

Springer eBooks•Jan 1, 1984•0 citations
A Michelson-type interferometer is built to dynamically lock the optical phase difference between the two-arm laser beams. The phase difference is tunable and allowed for continuous adjustments nearly by 160°. Under the best locking condition, a relative phase stability better than 0.1° is achieved starting from the original phase jitter of 10 to 15°. The interferometer is made by simply adding a pair of Brewster windows in one arm of the conventional setup, yet it provides much robust phase locking. It is readily applicable for optical lattice construction and nondestructive phase contrast imaging of ultracold atoms.
Power recycling techniques are usually used to improve the phase sensitivity of interferometers by reusing the input light energy, and can beat the shot noise level. Recent studies have demonstrated that the phase sensitivity of the interferometer is significantly improved via the addition of a recycling cavity, that is, coupling the interferometer with an external optical device. This study reviewed such types of interferometers named Grover-Michelson interferometers (GMI), and discusses their phase sensitivity with coherent states as inputs. Subsequently, a detailed comparison in terms of the scale of 1/ N and the standard quantum limit (SQL) is presented. The results demonstrate that the phase sensitivity of GMI improved owing to the power recycling and exceeded the value of 1/ N . Further, we proposed a modified Grover-Michelson interferometer (MGMI) with two input ports and examined its phase sensitivity with single photon or coherent states, respectively. Finally, in the presence of photon losses, we investigated the phase sensitivity of the four different interferometers, including MGMI, GMI, Mach-Zehnder interferometer (MZI), and SU(1,1) interferometer (SU(1,1)I), and conducted detailed comparisons. The results of this study indicated that the phase sensitivity of MGMI significantly improved owing to the increase in input energy, and MGMI exhibited the strongest robustness against photon number loss. These theoretical results are expected to facilitate improvements in interferometers and the detection of weak signals.