Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Magnetism and Magnetic Materials

A calibration method for coil constants using an atomic spin self-sustaining vector magnetometer

Q. Zhao, B.L. Fan, S.G. Wang, L.J. Wang

Published May 16, 2020• 13 citations
Publisher
DOI
10.1016/j.jmmm.2020.166977

Related papers

A method for calibrating coil constants by using an atomic spin co-magnetometer

Hong Zhang, Sheng Zou, Xiyuan Chen

The European Physical Journal D•Oct 1, 2016•28 citations

A vector atomic magnetometer based on the spin self-sustaining Larmor method

Q. Zhao, B.L. Fan, S.G. Wang +1 more

Journal of Magnetism and Magnetic Materials•Mar 6, 2019•16 citations

In Situ Calibration of Coils Constant in a Spin-Exchange Relaxation-Free (SERF) Co-magnetometer

Qian Cao, Ying Liu, Junjian Tang +3 more

Measurement•Mar 30, 2023•10 citations

Spin-decoupling calibration method for coil constants in optically pumped comagnetometers

Feng Li, Haoying Pang, Zhihong Wu +6 more

Measurement•Aug 29, 2025•6 citations

In-situ and synchronous calibration of coil constants and non-orthogonal angles based on electron resonance

Huijing Bai, Liwei Jiang, Yuntian Zou +6 more

Measurement•Apr 30, 2025•4 citations

A Coil Constant Calibration Method Based on the Phase-Frequency Response of Alkali Atomic Magnetometer

Han Yao, Danyue Ma, Junpeng Zhao +2 more

We propose an in-situ method to calibrate the coil constants of the optical atomic magnetometer. This method is based on measuring the Larmor precession of spin polarized alkali metal atoms and has been demonstrated on a K-Rb hybrid atomic magnetometer. Oscillation fields of different frequencies are swept on the transverse coil. By extracting the resonance frequency through phase-frequency analysis of electron spin projection, the coil constants are calibrated to be 323.1 ± 0.28 nT/mA, 108 ± 0.04 nT/Ma, and 185.8 ± 1.03 nT/mA along the X , Y , and Z directions, respectively.

Photonic Sensors•Jan 18, 2019•12 citations
We propose an in-situ method to calibrate the coil constants of the optical atomic magnetometer. This method is based on measuring the Larmor precession of spin polarized alkali metal atoms and has been demonstrated on a K-Rb hybrid atomic magnetometer. Oscillation fields of different frequencies are swept on the transverse coil. By extracting the resonance frequency through phase-frequency analysis of electron spin projection, the coil constants are calibrated to be 323.1 ± 0.28 nT/mA, 108 ± 0.04 nT/Ma, and 185.8 ± 1.03 nT/mA along the X , Y , and Z directions, respectively.