Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement

In-situ and synchronous calibration of coil constants and non-orthogonal angles based on electron resonance

Huijing Bai, Liwei Jiang, Yuntian Zou, Jiali Liu, Chi Fang, Jun Zhu, Qi Shao, Jinghong Xu, Wei Quan

Published Apr 30, 2025• 3 citations
Publisher
DOI
10.1016/j.measurement.2025.117627

Related papers

In Situ Calibration of Coils Constant in a Spin-Exchange Relaxation-Free (SERF) Co-magnetometer

Qian Cao, Ying Liu, Junjian Tang +3 more

Measurement•Mar 30, 2023•10 citations

In Situ Calibration of Coils Constant in a Spin-Exchange Relaxation-Free (Serf) Co-Magnetemator

Qian Cao, Ying Liu, Junjian Tang +3 more

•Jan 1, 2022•0 citations

A method for calibrating coil constants by using an atomic spin co-magnetometer

Hong Zhang, Sheng Zou, Xiyuan Chen

The European Physical Journal D•Oct 1, 2016•26 citations

A calibration method for coil constants using an atomic spin self-sustaining vector magnetometer

Q. Zhao, B.L. Fan, S.G. Wang +1 more

Journal of Magnetism and Magnetic Materials•May 16, 2020•11 citations

Spin-decoupling calibration method for coil constants in optically pumped comagnetometers

Feng Li, Haoying Pang, Zhihong Wu +6 more

Measurement•Aug 29, 2025•4 citations

In Situ Measurement of the Non‐Orthogonal Angles of Magnetic Field Coils Based on Single‐Beam Magnetic Resonance

Zhi Liu, Lihong Dong, Zhe Qi +3 more

Abstract This work proposes a novel method for in situ measurement of the non‐orthogonal angles of magnetic field coils based on single‐beam magnetic resonance. The orthogonality of magnetic field coils is crucial for ensuring the accuracy of atomic magnetometers. The theoretical principles are derived to establish a measurement method for the non‐orthogonal angles. The proposed method requires only one single beam of light to perform in situ measurements of non‐orthogonal angles in the YZ and XZ directions. The experimental results demonstrate that the angle between the Y and Z coils is 89.3001 ± 0.0045°, a value that remains stable despite variations in experimental parameters such as temperature and light power, thereby confirming the robustness of the method. Additionally, the measured gyromagnetic ratio is 6.9963 ± 0.0005 Hz nT −1 , which closely matches the theoretical value of 6.9958 Hz nT −1 , further validating the method's accuracy. The proposed method provides a more straightforward approach and has significant potential for widespread application across various atomic magnetometers, especially in miniaturized configurations. Furthermore, this method may be extended to the field of atomic gyroscopes.

Advanced Quantum Technologies•Aug 1, 2024•1 citation
Abstract This work proposes a novel method for in situ measurement of the non‐orthogonal angles of magnetic field coils based on single‐beam magnetic resonance. The orthogonality of magnetic field coils is crucial for ensuring the accuracy of atomic magnetometers. The theoretical principles are derived to establish a measurement method for the non‐orthogonal angles. The proposed method requires only one single beam of light to perform in situ measurements of non‐orthogonal angles in the YZ and XZ directions. The experimental results demonstrate that the angle between the Y and Z coils is 89.3001 ± 0.0045°, a value that remains stable despite variations in experimental parameters such as temperature and light power, thereby confirming the robustness of the method. Additionally, the measured gyromagnetic ratio is 6.9963 ± 0.0005 Hz nT −1 , which closely matches the theoretical value of 6.9958 Hz nT −1 , further validating the method's accuracy. The proposed method provides a more straightforward approach and has significant potential for widespread application across various atomic magnetometers, especially in miniaturized configurations. Furthermore, this method may be extended to the field of atomic gyroscopes.