Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Magnetism and Magnetic Materials

A vector atomic magnetometer based on the spin self-sustaining Larmor method

Q. Zhao, B.L. Fan, S.G. Wang, L.J. Wang

Published Mar 6, 2019• 14 citations
Publisher
DOI
10.1016/j.jmmm.2019.03.025

Related papers

A calibration method for coil constants using an atomic spin self-sustaining vector magnetometer

Q. Zhao, B.L. Fan, S.G. Wang +1 more

Journal of Magnetism and Magnetic Materials•May 16, 2020•11 citations

Progress on Novel Atomic Magnetometer and Gyroscope Based on Self-sustaining of Electron Spins

Shiguang Wang, Chi Xu, Y. Y. Feng +1 more

Lecture notes in electrical engineering•Jan 1, 2017•3 citations

Towards a compact accurate vector-scalar atomic magnetometer

Juniper W. Pollock, Svenja A. Knappe

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Investigation and improvement of the spin self-sustaining magnetometer

Q. Zhao, B. L. Fan, Shiguang Wang +1 more

The spin self-sustaining atomic magnetometer has the advantage of 1/τ measurement and great development potential in many applications. In this paper, we investigated the main elements that affect the stability and accuracy of the self-sustaining magnetometer and proposed the methods to improve its performance based on the measurement results. The correlation coefficient between fluctuations of the magnetic field generated by coils and the spin Larmor precession frequency is 0.97, which mainly dominates the stability in a short term. The accuracy of the magnetometer is affected by the power and frequency of the pump light. The Larmor precession frequency coefficient related to the pump light power is 26 mHz/mW, and the effect on the Larmor precession frequency is minimized when the pump light frequency is red detuned by 200 MHz from the 85Rb transition D1 line F = 3 to F′ = 3. The 1/τ measurement time after these corrections can be extended to 10 s, and the sensitivity achieved is 149 fT/Hz, which is close to the quantum projection noise limit of the system.

AIP Advances•Sep 1, 2020•0 citations

An atomic magnetic gradiometer with 1/τ uncertainty property based on the self-sustaining method

Qin Zhao, Boling Fan, Shiguang Wang +1 more

The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.

International Conference on Photonics and Optical Engineering•Jan 24, 2019•0 citations

Vectorial atomic magnetometer using electronic and nuclear

Binquan Zhou, Linlin Chen, Guanqun Lei +2 more

Bulletin of the American Physical Society•Jun 11, 2015•0 citations
The spin self-sustaining atomic magnetometer has the advantage of 1/τ measurement and great development potential in many applications. In this paper, we investigated the main elements that affect the stability and accuracy of the self-sustaining magnetometer and proposed the methods to improve its performance based on the measurement results. The correlation coefficient between fluctuations of the magnetic field generated by coils and the spin Larmor precession frequency is 0.97, which mainly dominates the stability in a short term. The accuracy of the magnetometer is affected by the power and frequency of the pump light. The Larmor precession frequency coefficient related to the pump light power is 26 mHz/mW, and the effect on the Larmor precession frequency is minimized when the pump light frequency is red detuned by 200 MHz from the 85Rb transition D1 line F = 3 to F′ = 3. The 1/τ measurement time after these corrections can be extended to 10 s, and the sensitivity achieved is 149 fT/Hz, which is close to the quantum projection noise limit of the system.
The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.