Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

AIP Advances

Investigation and improvement of the spin self-sustaining magnetometer

Q. Zhao, B. L. Fan, Shiguang Wang, L. J. Wang

Published Sep 1, 2020• 0 citations
Publisher

Abstract

The spin self-sustaining atomic magnetometer has the advantage of 1/τ measurement and great development potential in many applications. In this paper, we investigated the main elements that affect the stability and accuracy of the self-sustaining magnetometer and proposed the methods to improve its performance based on the measurement results. The correlation coefficient between fluctuations of the magnetic field generated by coils and the spin Larmor precession frequency is 0.97, which mainly dominates the stability in a short term. The accuracy of the magnetometer is affected by the power and frequency of the pump light. The Larmor precession frequency coefficient related to the pump light power is 26 mHz/mW, and the effect on the Larmor precession frequency is minimized when the pump light frequency is red detuned by 200 MHz from the 85Rb transition D1 line F = 3 to F′ = 3. The 1/τ measurement time after these corrections can be extended to 10 s, and the sensitivity achieved is 149 fT/Hz, which is close to the quantum projection noise limit of the system.

DOI
10.1063/5.0011720

Related papers

Note: An atomic self-sustaining magnetic gradiometer with a 1/τ uncertainty property based on Larmor precession

B. L. Fan, Shiguang Wang, Chi Xu +1 more

We demonstrate an atomic magnetic gradiometer based on self-sustaining Larmor precession. By coherent optical pumping, we measure the phase of the Larmor precession directly and observe that the gradiometer shows a 1/τ improvement in magnetic field gradient uncertainty over time τ. Since the measurement gives frequency signals, the gradiometer can be easily implemented by mixing and filtering the different frequency signals from two adjacent magnetometers. A gradient sensitivity of 186 fT/Hz/cm−1) is realized, which is close to the shot-noise limit. In a noisy environment, the gradiometer can still maintain its 1/τ behavior by suppressing 90% of the common-mode noise. This method should be widely applicable to the measurement of magnetic field gradients owing to its simplicity and outstanding performance.

Review of Scientific Instruments•Feb 1, 2018•4 citations

An atomic magnetic gradiometer with 1/τ uncertainty property based on the self-sustaining method

Qin Zhao, Boling Fan, Shiguang Wang +1 more

The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.

International Conference on Photonics and Optical Engineering•Jan 24, 2019•0 citations

A self-sustaining atomic magnetometer with τ−1 averaging property

Chi Xu, Shiguang Wang, Y. Y. Feng +2 more

Quantum measurement using coherent superposition of intrinsic atomic states has the advantage of being absolute measurement and can form metrological standards. One example is the absolute measurement of magnetic field by monitoring the Larmor precession of atomic spins whilst another being the Ramsey type atomic clock. Yet, in almost all coherent quantum measurement, the precision is limited by the coherence time beyond which, the uncertainty decreases only as τ(-1/2). Here we show that by non-destructively measuring the phase of the Larmor precession and regenerating the coherence via optical pumping, the self-sustaining Larmor precession signal can persist indefinitely. Consequently, the precision of the magnetometer increases with time following a much faster τ(-1) rule. A mean sensitivity of 240 from 1 Hz to 10 Hz is realized, being close to the shot noise level. This method of coherence regeneration may also find important applications in improving the performance of atomic clocks.

Scientific Reports•Jun 30, 2016•16 citations

Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises

Xiyuan Chen, Hong Zhang, Sheng Zou

Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.

Sensors•Jun 17, 2016•9 citations

Rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation

Pei-Xian Miao, Shiyu Yang, Wang Jian-Xiang +4 more

We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.

Acta Physica Sinica•Jan 1, 2017•11 citations

Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer

Jin Peng, An‐Ning Xu, Yiran Yin +1 more

The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.

IEEE Sensors Journal•Dec 7, 2023•11 citations
The spin self-sustaining atomic magnetometer has the advantage of 1/τ measurement and great development potential in many applications. In this paper, we investigated the main elements that affect the stability and accuracy of the self-sustaining magnetometer and proposed the methods to improve its performance based on the measurement results. The correlation coefficient between fluctuations of the magnetic field generated by coils and the spin Larmor precession frequency is 0.97, which mainly dominates the stability in a short term. The accuracy of the magnetometer is affected by the power and frequency of the pump light. The Larmor precession frequency coefficient related to the pump light power is 26 mHz/mW, and the effect on the Larmor precession frequency is minimized when the pump light frequency is red detuned by 200 MHz from the 85Rb transition D1 line F = 3 to F′ = 3. The 1/τ measurement time after these corrections can be extended to 10 s, and the sensitivity achieved is 149 fT/Hz, which is close to the quantum projection noise limit of the system.
We demonstrate an atomic magnetic gradiometer based on self-sustaining Larmor precession. By coherent optical pumping, we measure the phase of the Larmor precession directly and observe that the gradiometer shows a 1/τ improvement in magnetic field gradient uncertainty over time τ. Since the measurement gives frequency signals, the gradiometer can be easily implemented by mixing and filtering the different frequency signals from two adjacent magnetometers. A gradient sensitivity of 186 fT/Hz/cm−1) is realized, which is close to the shot-noise limit. In a noisy environment, the gradiometer can still maintain its 1/τ behavior by suppressing 90% of the common-mode noise. This method should be widely applicable to the measurement of magnetic field gradients owing to its simplicity and outstanding performance.
The magnetic field is one of the most important physical observables with about all electromagnetic information. Larmor precession atomic magnetometers based on optical pumping experienced considerable attention recently. However, the sensitivity of this kind of atomic magnetometers is limited by their spin coherence time and the systematic noise. Here, we propose a self-sustaining atomic magnetic gradiometer that shows a superior 1/τ behavior in the magnetic field uncertainty measurement over time. The gradiometer is implemented by mixing and filtering the different frequency signals from two adjacent spin self-sustaining magnetometers with a baseline equal to 1 cm. The common-mode noise is suppressed and a gradient sensitivity of 200 fT/(√Hz=cm) is realized, being close to the shot noise limit.
Quantum measurement using coherent superposition of intrinsic atomic states has the advantage of being absolute measurement and can form metrological standards. One example is the absolute measurement of magnetic field by monitoring the Larmor precession of atomic spins whilst another being the Ramsey type atomic clock. Yet, in almost all coherent quantum measurement, the precision is limited by the coherence time beyond which, the uncertainty decreases only as τ(-1/2). Here we show that by non-destructively measuring the phase of the Larmor precession and regenerating the coherence via optical pumping, the self-sustaining Larmor precession signal can persist indefinitely. Consequently, the precision of the magnetometer increases with time following a much faster τ(-1) rule. A mean sensitivity of 240 from 1 Hz to 10 Hz is realized, being close to the shot noise level. This method of coherence regeneration may also find important applications in improving the performance of atomic clocks.
Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.
We report a rubidium atomic magnetometer based on pump-probe nonlinear magneto-optical rotation. The rubidium vapor cell is placed in a five-layer magnetic shield with inner coils that can generate uniform magnetic fields along the direction of pump beam, and the cell is also placed in the center of a Helmholtz coil that can generate an oscillating magnetic field perpendicular to the direction of pump beam. The atoms are optically pumped by circularly polarized pump beam along a constant magnetic field in a period of time, then the pump beam is turned off and a /2 pulse of oscillating magnetic field for 87Rb atoms is applied. After the above process, the individual atomic magnetic moments become phase coherent, resulting in a transverse magnetization vector precessing at the Larmor frequency in the magnetic field. The linearly polarized probing beam is perpendicular to the direction of magnetic field, and can be seen as a superposition of the left and right circularly polarized light. Because of the different absorptions and dispersions of the left and right circularly polarized light by rubidium atoms, the polarization direction of probing beam rotates when probing beam passes through rubidium vapor cell. The rotation of the polarization is subsequently converted into an electric signal through a polarizing beam splitter. Finally, the decay signal related to the transverse magnetization vector is measured. The Larmor frequency proportional to magnetic field is obtained by the Fourier transform of the decay signal. The value of magnetic field is calculated from the formula:B=(2/) f, where and f are the gyromagnetic ratio and Larmor frequency, respectively. In order to measure the magnetic field in a wide range, the tracking lock mode is proposed and tested. The atomic magnetometer can track the magnetic field jump of 1000 nT or 10000 nT, indicating that the atomic magnetometer has strong locking ability and can be easily locked after start-up. The main performances in different magnetic fields are tested. The results show that the measurement range of the atomic magnetometer is from 100 nT to 100000 nT, the extreme sensitivity is 0.2 pT/Hz1/2, and the magnetic field resolution is 0.1 pT. The transverse relaxation times of the transverse magnetization vector in different magnetic fields are obtained, and the relaxation time decreases with the increase of the magnetic field. When the measurement range is from 5000 nT to 100000 nT, the magnetic field sampling rate of the atomic magnetometer can be adjusted in a range from 1 Hz to 1000 Hz. The atomic magnetometer in high sampling rate can measure weak alternating magnetic field at low frequency. This paper provides an important reference for developing the atomic magnetometer with large measurement range, high sensitivity and high sampling rate.
The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.