Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Progress Towards a Commercial 171Yb+ Microwave Atomic Frequency Standard

J. Tallant, Jay Noble, D. Guan, N. Dao, K. Richard Overstreet

Published Apr 1, 2019• 2 citations
Publisher

Abstract

We report our progress on a high-precision microwave frequency standard that is based on trapped171Yb+ions. In the presence of a buffer gas, a short-term stability of 8e13 at 1s and 1e-12/√(t) for times less than 100 s is demonstrated. Laser-cooling is demonstrated to produce a crystal whose unique decay pattern prohibits closed-loop clock operation.

DOI
10.1109/fcs.2019.8856096

Related papers

Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal

N. C. Xin, H. R. Qin, Miao, S. N. +4 more

We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to $8.5 \times {10^{ - 13}}/\sqrt \tau$ for averaging times between 10 and 1000 s.

arXiv:2201.02937•Jan 9, 2022•0 citations

A Portable Microwave Clock Using Laser-Cooled Trapped 171Yb+Ions

Sean Mulholland, S. Donnellan, G. P. Barwood +7 more

A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2018•3 citations

Miniature microwave frequency standard with trapped 171Yb+

Yuan‐Yu Jau, Peter D. D. Schwindt, Adrian L. Casias +12 more

We report the development of a low-power, miniature Yb-171 ion clock at Sandia National Laboratories. This work is funded by the DARPA micro Position, Navigation, and Timing program under the Integrated Micro Primary Atomic Clock Technology (IMPACT) project. The ultimate goal is to develop a frequency standard that has frequency stability comparable to a commercial Cs beam standard, but with 100 to 1000 times smaller size and power consumption. The Yb-171 ion has a microwave clock traItem MIN :YXB4-01335-A112nsition at 12.6 GHz, and the natural linewidth of the clock resonance is expected to be less than 10-3Hz, which leads to a very high-Q clock resonance. An atomic clock using trapped ions is an excellent candidate for miniaturization because ions are well isolated from the environment independently of the size of the trap. Compared to optical traps for neutral atoms, the trapping depth of RF traps for ions is usually several orders of magnitude deeper. Therefore, the requirement for the vacuum level is more forgiving. We have successfully developed miniature ion-trap vacuum packages as shown in Fig. 1. Usually, a few microTorr of He buffer gas is introduced into each of our miniature ion-trap vacuum packages, which are sealed and passively pumped by non-evaporable getters. Using a sealed 3 cc ion-trap package, we were able to demonstrate long-term clock operation, with the stability reaching the 10-14range after a few days of integration [1].

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•0 citations

Laser-cooled 171Yb+ microwave frequency standard with a short-term frequency instability of 8.5 × 10−13/√τ

N. C. Xin, H. R. Qin, S. N. Miao +5 more

We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.

Optics Express•Apr 19, 2022•25 citations

Single Trapped 171Yb+ for Optical Frequency Standards

Atish Roy, Lakhi Sharma, Harish Kumar Rathore +5 more

An optical clock or frequency standard based on the interrogation of an atomic transition in the optical domain, operates at ~1014Hz is capable of providing orders of magnitude better accuracy than the present primary standard of frequency or time operating in the microwave range. Optical transitions of an ions, confined within a radio frequency ion trap and laser cooled to ~mK temperature, provides better long term stability since they are free from Coulomb and intra-atomic interactions. Optical frequency standards have been realized with several ions, e.g.,199Hg+,171Yb+,115In+,88Sr+,40Ca+,27Al+and among those171Y+has multiple ultra-narrow optical transitions suitable for serving as frequency standards [1-2].

URSI Asia-Pacific Radio Science Conference•Mar 1, 2019•0 citations

Towards a high-performance microwave frequency standard based on 113Cd+ ions

Jianwei Zhang, K. Miao, Lijun Wang +2 more

Microwave frequency standards based on ions are promising as the next generation atomic clocks. This paper reports the recent progresses of the microwave frequency standard based on laser-cooled113Cd+ions developed at Tsinghua University. Based on the current experimental setup, the ground-state hyperfine splitting of113Cd+is measured with higher precision and a better short-term frequency stability is obtained than before. To improve the performance of the Cd+clock further, a new experimental setup with dual-traps is designed, and bi-ions operation is proposed.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•3 citations
We report our progress on a high-precision microwave frequency standard that is based on trapped171Yb+ions. In the presence of a buffer gas, a short-term stability of 8e13 at 1s and 1e-12/√(t) for times less than 100 s is demonstrated. Laser-cooling is demonstrated to produce a crystal whose unique decay pattern prohibits closed-loop clock operation.
We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to 8.5×10−13/τ8.5 \times {10^{ - 13}}/\sqrt \tau8.5×10−13/τ​ for averaging times between 10 and 1000 s.
A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.
We report the development of a low-power, miniature Yb-171 ion clock at Sandia National Laboratories. This work is funded by the DARPA micro Position, Navigation, and Timing program under the Integrated Micro Primary Atomic Clock Technology (IMPACT) project. The ultimate goal is to develop a frequency standard that has frequency stability comparable to a commercial Cs beam standard, but with 100 to 1000 times smaller size and power consumption. The Yb-171 ion has a microwave clock traItem MIN :YXB4-01335-A112nsition at 12.6 GHz, and the natural linewidth of the clock resonance is expected to be less than 10-3Hz, which leads to a very high-Q clock resonance. An atomic clock using trapped ions is an excellent candidate for miniaturization because ions are well isolated from the environment independently of the size of the trap. Compared to optical traps for neutral atoms, the trapping depth of RF traps for ions is usually several orders of magnitude deeper. Therefore, the requirement for the vacuum level is more forgiving. We have successfully developed miniature ion-trap vacuum packages as shown in Fig. 1. Usually, a few microTorr of He buffer gas is introduced into each of our miniature ion-trap vacuum packages, which are sealed and passively pumped by non-evaporable getters. Using a sealed 3 cc ion-trap package, we were able to demonstrate long-term clock operation, with the stability reaching the 10-14range after a few days of integration [1].
We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.
An optical clock or frequency standard based on the interrogation of an atomic transition in the optical domain, operates at ~1014Hz is capable of providing orders of magnitude better accuracy than the present primary standard of frequency or time operating in the microwave range. Optical transitions of an ions, confined within a radio frequency ion trap and laser cooled to ~mK temperature, provides better long term stability since they are free from Coulomb and intra-atomic interactions. Optical frequency standards have been realized with several ions, e.g.,199Hg+,171Yb+,115In+,88Sr+,40Ca+,27Al+and among those171Y+has multiple ultra-narrow optical transitions suitable for serving as frequency standards [1-2].
Microwave frequency standards based on ions are promising as the next generation atomic clocks. This paper reports the recent progresses of the microwave frequency standard based on laser-cooled113Cd+ions developed at Tsinghua University. Based on the current experimental setup, the ground-state hyperfine splitting of113Cd+is measured with higher precision and a better short-term frequency stability is obtained than before. To improve the performance of the Cd+clock further, a new experimental setup with dual-traps is designed, and bi-ions operation is proposed.