Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal

N. C. Xin, H. R. Qin, Miao, S. N., Chen, Y. T., Han, J. Z., J. W. Zhang, L. J. Wang

Published Jan 9, 2022• 0 citations
arXivHTMLPDF

Abstract

We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to $8.5 \times {10^{ - 13}}/\sqrt \tau$ for averaging times between 10 and 1000 s.

DOI
10.48550/arxiv.2201.02937

Related papers

Laser-cooled 171Yb+ microwave frequency standard with a short-term frequency instability of 8.5 × 10−13/√τ

N. C. Xin, H. R. Qin, S. N. Miao +5 more

We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.

Optics Express•Mar 22, 2022•24 citations

A Portable Microwave Clock Using Laser-Cooled Trapped 171Yb+Ions

Sean Mulholland, S. Donnellan, G. P. Barwood +7 more

A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2018•2 citations

Miniature trapped-ion frequency standard with 171Yb+

Peter D. D. Schwindt, Yuan‐Yu Jau, Heather L. Partner +14 more

We describe the development and frequency instability measurements of a highly miniaturized, buffer gas cooled, trapped-ion atomic clock. The clock utilizes the 12.6 GHz hyperfine transition of the171Yb+ion. A custom-built 3 cm3vacuum package containing the ion trap is integrated with other key elements of the atomic frequency standard, including a photo multiplier tube, miniaturized laser sources at 369 nm and 935 nm, a local oscillator, and control electronics. With the clock physics package assembled on a 10 cm × 15 cm breadboard, the long-term fractional frequency instability was measured to be 6 × 10-14at 25 days of integration. Later, the clock physics package was further miniaturized, and the frequency instability was measured to be 2 × 10-11/τ1/2at integration times up to 10,000 s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•11 citations

Progress Towards a Commercial 171Yb+ Microwave Atomic Frequency Standard

J. Tallant, Jay Noble, D. Guan +2 more

We report our progress on a high-precision microwave frequency standard that is based on trapped171Yb+ions. In the presence of a buffer gas, a short-term stability of 8e13 at 1s and 1e-12/√(t) for times less than 100 s is demonstrated. Laser-cooling is demonstrated to produce a crystal whose unique decay pattern prohibits closed-loop clock operation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•2 citations

Portable, laser-cooled ytterbium ion frequency standard

Sean Mulholland, Hugh A. Klein, G. P. Barwood +6 more

We report on the development of a portable, trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit ($51\times49\times28$ cm) and comprises laser, electronics and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be $3.6\times10^{-12}/\surd\tau$ for averaging times between 30 s and 1500 s.

•Nov 15, 2018•1 citation

Progress on cadmium-ion and ytterbium-ion Microwave Frequency Standards at Tsinghua University

S. N. Miao, Yajing Zheng, Yong Chen +3 more

Abstract As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance 113Cd+ microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of 4.2 × 10 − 13 / τ and a relative frequency uncertainty of 1.8 × 10−14, improving nearly three orders of magnitude compared to the result from JPL. The 0-0 ground-state hyperfine splitting frequency of 113Cd+ was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using 40Ca+ as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to 3.48 × 10 − 13 / τ . Moreover, a microwave frequency standard based on laser-cooled 171Yb+ ions has also been developed in our laboratory since 2021. The short-term frequency instability was measured to be 8.5 × 10 − 13 / τ . The ground-state hyperfine splitting frequency of 171Yb+ was determined to be 12642812118.4674(8) Hz with a fractional frequency uncertainty of 6.33 × 10−14.

Journal of Physics Conference Series•Nov 1, 2024•0 citations
We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to 8.5×10−13/τ8.5 \times {10^{ - 13}}/\sqrt \tau8.5×10−13/τ​ for averaging times between 10 and 1000 s.
We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.
A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.
We describe the development and frequency instability measurements of a highly miniaturized, buffer gas cooled, trapped-ion atomic clock. The clock utilizes the 12.6 GHz hyperfine transition of the171Yb+ion. A custom-built 3 cm3vacuum package containing the ion trap is integrated with other key elements of the atomic frequency standard, including a photo multiplier tube, miniaturized laser sources at 369 nm and 935 nm, a local oscillator, and control electronics. With the clock physics package assembled on a 10 cm × 15 cm breadboard, the long-term fractional frequency instability was measured to be 6 × 10-14at 25 days of integration. Later, the clock physics package was further miniaturized, and the frequency instability was measured to be 2 × 10-11/τ1/2at integration times up to 10,000 s.
We report on the development of a portable, trapped-ion, microwave frequency standard based on the 12.6 GHz hyperfine transition in laser-cooled ytterbium-171 ions. The entire system fits into a 6U 19-inch rack unit (51×49×2851\times49\times2851×49×28 cm) and comprises laser, electronics and physics package subsystems. The performance of this development system is evaluated; the fractional frequency instability was measured to be 3.6×10−12/√τ3.6\times10^{-12}/\surd\tau3.6×10−12/√τ for averaging times between 30 s and 1500 s.
Abstract As a candidate for the next generation microwave clock, microwave atomic clocks based on trapped ions are currently studied worldwide. Since 2010, our team at Tsinghua University has been committed to developing a high-performance 113Cd+ microwave ion clock. In 2021, the laser-cooled cadmium-ion microwave clock constructed in our laboratory demonstrated remarkable performance, with a short-term instability of 4.2 × 10 − 13 / τ and a relative frequency uncertainty of 1.8 × 10−14, improving nearly three orders of magnitude compared to the result from JPL. The 0-0 ground-state hyperfine splitting frequency of 113Cd+ was determined to be 15199862855.02799(27) Hz, currently the most accurate measurement result for this transition frequency. Apart from that, we introduced the sympathetic cooling technology into the experiment of cadmium-ion microwave clock. Using 40Ca+ as the coolant ion, we obtained Ramsey patterns with a free evolution time of up to 100 seconds, ultimately improving the short-term instability of the system to 3.48 × 10 − 13 / τ . Moreover, a microwave frequency standard based on laser-cooled 171Yb+ ions has also been developed in our laboratory since 2021. The short-term frequency instability was measured to be 8.5 × 10 − 13 / τ . The ground-state hyperfine splitting frequency of 171Yb+ was determined to be 12642812118.4674(8) Hz with a fractional frequency uncertainty of 6.33 × 10−14.