Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

A Portable Microwave Clock Using Laser-Cooled Trapped 171Yb+Ions

Sean Mulholland, S. Donnellan, G. P. Barwood, David Gentle, Guozheng Huang, Hugh A. Klein, P. Patel, G. Walsh, P. E. G. Baird, P. Gill

Published May 1, 2018• 3 citations
Publisher

Abstract

A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.

DOI
10.1109/fcs.2018.8597512

Related papers

Development of a portable laser-cooled ytterbium ion microwave atomic clock

Sean Mulholland

Portable microwave clocks that incorporate laser cooling promise to bring significantly improved performance compared to commercially available microwave clocks that are based on thermal atoms. This thesis reports on the development of a portable, laser-cooled ytterbium-171 trapped-ion microwave frequency standard from design to testing.

•Jan 1, 2019•4 citations

Progress toward a microwave frequency standard based on laser-cooled large scale 171Yb+ ion crystal

N. C. Xin, H. R. Qin, Miao, S. N. +4 more

We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to $8.5 \times {10^{ - 13}}/\sqrt \tau$ for averaging times between 10 and 1000 s.

arXiv:2201.02937•Jan 9, 2022•0 citations

Laser-cooled 171Yb+ microwave frequency standard with a short-term frequency instability of 8.5 × 10−13/√τ

N. C. Xin, H. R. Qin, S. N. Miao +5 more

We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.

Optics Express•Apr 19, 2022•25 citations

Subsystems and design for a transportable cold ion microwave clock

M. A. Trigatzis, Ulas Sabahattin Gokay, Martin Knapp +6 more

High performance transportable microwave atomic clocks are enablers for resilient GNSS-free timescales. We present progress towards a transportable laser-cooled ytterbium ion microwave clock. This system incorporates our recently developed multi-ion trap chamber and redesigned electronics and optics systems, offering reductions in size, weight and power, with improved performance over our previous system. The benchtop prototype version of this clock uses the new physics package design and reaches a short-term instability of 1.2 × 10−12/√τ. We present the transportable clock design as well as subsystem test results, which so far indicate that a similar performance to the benchtop version is achievable in a 3U rack-mounted package.

IET conference proceedings.•Aug 1, 2025•1 citation

Miniature trapped-ion frequency standard with 171Yb+

Peter D. D. Schwindt, Yuan‐Yu Jau, Heather L. Partner +14 more

We describe the development and frequency instability measurements of a highly miniaturized, buffer gas cooled, trapped-ion atomic clock. The clock utilizes the 12.6 GHz hyperfine transition of the171Yb+ion. A custom-built 3 cm3vacuum package containing the ion trap is integrated with other key elements of the atomic frequency standard, including a photo multiplier tube, miniaturized laser sources at 369 nm and 935 nm, a local oscillator, and control electronics. With the clock physics package assembled on a 10 cm × 15 cm breadboard, the long-term fractional frequency instability was measured to be 6 × 10-14at 25 days of integration. Later, the clock physics package was further miniaturized, and the frequency instability was measured to be 2 × 10-11/τ1/2at integration times up to 10,000 s.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•13 citations

Progress Towards a Commercial 171Yb+ Microwave Atomic Frequency Standard

J. Tallant, Jay Noble, D. Guan +2 more

We report our progress on a high-precision microwave frequency standard that is based on trapped171Yb+ions. In the presence of a buffer gas, a short-term stability of 8e13 at 1s and 1e-12/√(t) for times less than 100 s is demonstrated. Laser-cooling is demonstrated to produce a crystal whose unique decay pattern prohibits closed-loop clock operation.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•2 citations
A portable microwave clock incorporating laser-cooling of171Yb+promises to bring significantly improved performance compared to existing thermal commercial devices. We report on progress in the development of a compact microwave frequency standard designed to fit in a 19-inch rack enclosure that comprises laser, electronics and physics package subsystems. Recent results in which a local oscillator was disciplined by laser-cooled trapped171Yb+ions are presented. Preliminary measurements have demonstrated a fractional frequency instability of 1 × 10-13at 10,000 s. Potential applications include telecommunications and financial operations time reference systems as well as navigation system integrity.
We report on progress towards a microwave frequency standard based on a laser-cooled 171Yb+ ion trap system. The electronics, lasers, and magnetic shields are integrated into a single physical package. With over 1E5 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171Yb+ microwave clock was further improved to 8.5×10−13/τ8.5 \times {10^{ - 13}}/\sqrt \tau8.5×10−13/τ​ for averaging times between 10 and 1000 s.
We report on the development of a microwave frequency standard based on a laser-cooled 171 Y b + ion trap system. The electronics , lasers, and magnetic shields are integrated into a single physical package. With over 105 ions are stably trapped, the system offers a high signal-to-noise ratio Ramsey line-shape. In comparison with previous work, the frequency instability of a 171 Y b + microwave clock was further improved to 8.5 × 10 − 13 / τ for averaging times between 10 and 1000 s. Essential systematic shifts and uncertainties are also estimated.
High performance transportable microwave atomic clocks are enablers for resilient GNSS-free timescales. We present progress towards a transportable laser-cooled ytterbium ion microwave clock. This system incorporates our recently developed multi-ion trap chamber and redesigned electronics and optics systems, offering reductions in size, weight and power, with improved performance over our previous system. The benchtop prototype version of this clock uses the new physics package design and reaches a short-term instability of 1.2 × 10−12/√τ. We present the transportable clock design as well as subsystem test results, which so far indicate that a similar performance to the benchtop version is achievable in a 3U rack-mounted package.
We describe the development and frequency instability measurements of a highly miniaturized, buffer gas cooled, trapped-ion atomic clock. The clock utilizes the 12.6 GHz hyperfine transition of the171Yb+ion. A custom-built 3 cm3vacuum package containing the ion trap is integrated with other key elements of the atomic frequency standard, including a photo multiplier tube, miniaturized laser sources at 369 nm and 935 nm, a local oscillator, and control electronics. With the clock physics package assembled on a 10 cm × 15 cm breadboard, the long-term fractional frequency instability was measured to be 6 × 10-14at 25 days of integration. Later, the clock physics package was further miniaturized, and the frequency instability was measured to be 2 × 10-11/τ1/2at integration times up to 10,000 s.