Conference on Lasers and Electro-Optics

Quantum Limit for Two-Dimensional Resolution of Two Incoherent Optical Point Sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

Published Jan 1, 2016• 2 citations
Publisher

Abstract

We obtain the quantum Cramér-Rao (QCR) bound for estimating the 2-D separation of two incoherent optical point sources. The bound is independent of the x- and y-separations. We also propose an interferometric scheme that approaches the bound for sub-Rayleigh separations.
DOI
10.1364/cleo_at.2016.jtu5a.21

Related papers

Quantum limit for two-dimensional resolution of two incoherent optical point sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.

arXiv:1606.00603•Physical Review A•Jun 29, 2017•96 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Achieving quantum-limited optical resolution

Martin Paùr, B. Stoklasa, Z. Hradil +2 more

We establish a simple method to assess the quantum Fisher information required for resolving two incoherent point sources with an imaging system. The resulting Cramér-Rao bound shows that the standard Rayleigh limit can be surpassed by suitable coherent measurements. We explicitly find these optimal strategies and present a realization for Gaussian and slit apertures. This involves a projection onto the optimal bases that is accomplished with digital holographic techniques and is compared with a CCD position measurement. Our experimental results unequivocally confirm unprecedented sub-Rayleigh precision.

arXiv:1606.08332•Jun 27, 2016•5 citations

Experimental source separation estimation reaching the Cramér-Rao bound

David Barral, Clémentine Rouvière, Antonin Grateau +5 more

We experimentally implement the separation estimation between to incoherent optical sources. Our method, relying on spatial-mode demultiplexing and intensity measurements, saturates the Cramèr-Rao bound, with a five orders of magnitude gain compared to the Rayleigh limit.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

Towards Superresolution Surface Metrology: Quantum Estimation of Angular and Axial Separations

Carmine Napoli, Samanta Piano, Richard Leach +2 more

We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.

arXiv:1805.04116•Physical Review Letters•Apr 12, 2019•81 citations

Experimental separation estimation of incoherent optical sources reaching the (quantum) Cramér-Rao bound

Clémentine Rouvière, David Barral, Antonin Grateau +4 more

Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1–3]. Our experimental setup allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].

Photonics North (PN)•Jun 12, 2023•0 citations
We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the xxx and yyy components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
We establish a simple method to assess the quantum Fisher information required for resolving two incoherent point sources with an imaging system. The resulting Cramér-Rao bound shows that the standard Rayleigh limit can be surpassed by suitable coherent measurements. We explicitly find these optimal strategies and present a realization for Gaussian and slit apertures. This involves a projection onto the optimal bases that is accomplished with digital holographic techniques and is compared with a CCD position measurement. Our experimental results unequivocally confirm unprecedented sub-Rayleigh precision.
We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.
Resolving light sources below the diffraction limit is a fundamental task both for astronomy and microscopy. Several recent works analysed this problem through the lens of quantum parameter estimation theory and proved that the separation between two point sources can be estimated at the quantum limit using intensity measurements after spatial-mode demultiplexing. We implement this technique and provide an optimal estimator based on a linear combination of demultiplexed intensity measurements [1–3]. Our experimental setup allows for the generation of the images of two sources, with tunable mutual coherence, as well as for spatial mode demultiplexing to estimate their separation [4].