Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

Rayleigh’s Criterion is Irrelevant to the Localization of Two Incoherent Optical Point Sources

Mankei Tsang, Ranjith Nair, Xiao-Ming Lu

Published Jan 1, 2016• 0 citations
Publisher

Abstract

Using the quantum Cramer-Rao bound, we prove that Rayleigh's criterion is fundamentally irrelevant to the estimation of the separation between two incoherent optical sources. We also propose measurement schemes that attain the bound.
DOI
10.1364/cleo_qels.2016.ff1c.1

Related papers

Quantum Limit for Two-Dimensional Resolution of Two Incoherent Optical Point Sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the quantum Cramér-Rao (QCR) bound for estimating the 2-D separation of two incoherent optical point sources. The bound is independent of the x- and y-separations. We also propose an interferometric scheme that approaches the bound for sub-Rayleigh separations.

Conference on Lasers and Electro-Optics•Jan 1, 2016•3 citations

Beating Rayleigh’s criterion: Superresolution of thermal sources with linear optics

Ranjith Nair, Mankei Tsang

We obtain the quantum Cramér-Rao bound for estimating the transverse separation between two thermal point sources of any intensity using a given imaging system. Two linear optics schemes that approach it are also proposed.

Quantum Information and Measurement (QIM)•Jan 1, 2017•1 citation

Quantum Theory of Superresolution for Two Incoherent Optical Point Sources

Mankei Tsang, Ranjith Nair, Xiao-Ming Lu

Rayleigh's criterion for resolving two incoherent point sources has been the most influential measure of optical imaging resolution for over a century.In the context of statistical image processing, violation of the criterion is especially detrimental to the estimation of the separation between the sources, and modern far-field superresolution techniques rely on suppressing the emission of close sources to enhance the localization precision.Using quantum optics, quantum metrology, and statistical analysis, here we show that, even if two close incoherent sources emit simultaneously, measurements with linear optics and photon counting can estimate their separation from the far field almost as precisely as conventional methods do for isolated sources, rendering Rayleigh's criterion irrelevant to the problem.Our results demonstrate that superresolution can be achieved not only for fluorophores but also for stars.

arXiv:1511.00552•Physical Review X•Aug 29, 2016•511 citations

Quantum limit for two-dimensional resolution of two incoherent optical point sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.

arXiv:1606.00603•Physical Review A•Jun 29, 2017•107 citations

Experimental source separation estimation reaching the Cramér-Rao bound

David Barral, Clémentine Rouvière, Antonin Grateau +5 more

We experimentally implement the separation estimation between to incoherent optical sources. Our method, relying on spatial-mode demultiplexing and intensity measurements, saturates the Cramèr-Rao bound, with a five orders of magnitude gain compared to the Rayleigh limit.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•170 citations
Rayleigh's criterion for resolving two incoherent point sources has been the most influential measure of optical imaging resolution for over a century.In the context of statistical image processing, violation of the criterion is especially detrimental to the estimation of the separation between the sources, and modern far-field superresolution techniques rely on suppressing the emission of close sources to enhance the localization precision.Using quantum optics, quantum metrology, and statistical analysis, here we show that, even if two close incoherent sources emit simultaneously, measurements with linear optics and photon counting can estimate their separation from the far field almost as precisely as conventional methods do for isolated sources, rendering Rayleigh's criterion irrelevant to the problem.Our results demonstrate that superresolution can be achieved not only for fluorophores but also for stars.
We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the xxx and yyy components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.