Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1709.07705 · Physical Review A

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa, Martin Paùr, Jai Grover, A. Krzic, Luis Lorenzo Sánchez-Soto

Published Dec 7, 2017• 169 citations
arXivHTMLPDF

Abstract

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

DOI
10.1103/physreva.96.062107

Related papers

Quantum limit for two-dimensional resolution of two incoherent optical point sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.

arXiv:1606.00603•Physical Review A•Jun 29, 2017•96 citations

Multiparameter approach to experimental separation estimation of unequally bright sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque +1 more

Due to the wave nature of light, optical imaging is inherently subject to diffraction, which typically dictates the resolution limit for two-point sources. A practical way to describe this phenomenon is through Rayleigh’s criterion, which states that two sources are barely resolvable when the minimum of one source's diffraction pattern coincides with the maximum of the other. However, recent advances in optical quantum metrology have shown that this classical limit can be surpassed by leveraging the spatial correlations within the light field. Specifically, decomposing the light into a Hermite-Gauss mode basis provides substantially more information than traditional direct imaging, which measures local intensity [1,2,3]. In this work, we implement a spatial demultiplexing technique to estimate the separation between light sources of unequal brightness. This unknown imbalance adds complexity to the estimation task, making it inherently a multiparameter problem and thus requiring a multimode approach [4]. By optimizing the measurement strategy and introducing a shift between two demultiplexers, we achieve sub-Rayleigh resolution in distance measurements without assuming prior knowledge of the intensity imbalance or alignment. [1] Tsang, M., Nair, R., & Lu, X. M. (2016). Quantum theory of superresolution for two incoherent optical point sources. Physical Review X, 6(3), 031033. [2] Sorelli, G., Gessner, M., Walschaers, M., & Treps, N. (2021). Optimal observables and estimators for practical superresolution imaging. Physical Review Letters, 127(12), 123604. [3] Rouvière, C., Barral, D., Grateau, A., Karuseichyk, I., Sorelli, G., Walschaers, M., & Treps, N. (2024). Ultra-sensitive separation estimation of optical sources. Optica, 11(2), 166-170. [4] Řeháček, J., Hradil, Z., Koutný, D., Grover, J., Krzic, A., & Sánchez-Soto, L. L. (2018). Optimal measurements for quantum spatial superresolution. Physical review A, 98(1), 012103.

SPIE Quantum Technologies for Defence and Security•Oct 29, 2025•0 citations

Multiparameter estimation for the superresolution of two incoherent sources

Antonin Grateau, Alexander Boeschoten, Tanguy Favin-Lévêque +2 more

We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.

quant-pharXiv:2601.14876•Physical Review Letters•Jan 22, 2026•0 citations

Optimal quantum superresolution for full distance between incoherent optical sources in two dimensions

Junyan Li, Shengshi Pang

The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.

arXiv:2508.08049•Physical Review A•Feb 12, 2026•0 citations

Towards Realistic Superresolution of Incoherent Point Sources

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cramér-Rao bound for quantum inspired imaging of two incoherent point sources and discuss the optimal detection schemes achieving the ultimate precision predicted by quantum theory thus paving the way for future practical implementations.

Imaging and Applied Optics•Jan 1, 2018•0 citations

Towards Superresolution Surface Metrology: Quantum Estimation of Angular and Axial Separations

Carmine Napoli, Samanta Piano, Richard Leach +2 more

We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.

arXiv:1805.04116•Physical Review Letters•Apr 12, 2019•81 citations
We establish the multiparameter quantum Cram'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the xxx and yyy components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.
Due to the wave nature of light, optical imaging is inherently subject to diffraction, which typically dictates the resolution limit for two-point sources. A practical way to describe this phenomenon is through Rayleigh’s criterion, which states that two sources are barely resolvable when the minimum of one source's diffraction pattern coincides with the maximum of the other. However, recent advances in optical quantum metrology have shown that this classical limit can be surpassed by leveraging the spatial correlations within the light field. Specifically, decomposing the light into a Hermite-Gauss mode basis provides substantially more information than traditional direct imaging, which measures local intensity [1,2,3]. In this work, we implement a spatial demultiplexing technique to estimate the separation between light sources of unequal brightness. This unknown imbalance adds complexity to the estimation task, making it inherently a multiparameter problem and thus requiring a multimode approach [4]. By optimizing the measurement strategy and introducing a shift between two demultiplexers, we achieve sub-Rayleigh resolution in distance measurements without assuming prior knowledge of the intensity imbalance or alignment. [1] Tsang, M., Nair, R., & Lu, X. M. (2016). Quantum theory of superresolution for two incoherent optical point sources. Physical Review X, 6(3), 031033. [2] Sorelli, G., Gessner, M., Walschaers, M., & Treps, N. (2021). Optimal observables and estimators for practical superresolution imaging. Physical Review Letters, 127(12), 123604. [3] Rouvière, C., Barral, D., Grateau, A., Karuseichyk, I., Sorelli, G., Walschaers, M., & Treps, N. (2024). Ultra-sensitive separation estimation of optical sources. Optica, 11(2), 166-170. [4] Řeháček, J., Hradil, Z., Koutný, D., Grover, J., Krzic, A., & Sánchez-Soto, L. L. (2018). Optimal measurements for quantum spatial superresolution. Physical review A, 98(1), 012103.
We experimentally demonstrate the simultaneous estimation of the three parameters characterizing a pair of incoherent optical sources in the sub-Rayleigh regime, enabling super-resolved scene characterization. Using spatial-mode demultiplexing (SPADE) with two demultiplexers--one deliberately shifted--we determine separations well below the diffraction limit and achieve sensitive joint estimation of separation, centroid, and relative brightness over a broad range of scene configurations in a single experimental setting. We benchmark our performance using Fisher-information-based Cramér-Rao bounds, and discuss the corresponding quantum limits. We investigate two complementary scenarios: a realistic case with slightly non-identical sources, and an idealized case of indistinguishable sources.
The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.
We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.