Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2508.08049 · Physical Review A

Optimal quantum superresolution for full distance between incoherent optical sources in two dimensions

Junyan Li, Shengshi Pang

Published Feb 12, 2026• 0 citations
arXivHTMLPDF

Abstract

The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.

DOI
10.1103/tzyy-cwb4

Related papers

Quantum-Limited Distance Estimation in Three-Dimensional Optical Superresolution

Junyan Li, Shengshi Pang

Quantum superresolution reveals that the vanishing of separation sensitivity in conventional imaging below the Rayleigh limit does not necessarily indicate a fundamental loss of information in the optical field. However, the quantum limit for estimating the physical distance between two incoherent point sources in three-dimensional imaging systems and its dependence on the spatial structure of the point-spread function remains largely unknown. In this work, we derive the quantum-limited precision for estimating the full distance between two incoherent point sources with arbitrary intensity imbalance in a three-dimensional spatially invariant imaging system. We show that the distance information remains finite in the sub-Rayleigh regime and is governed by the second-order displacement-response tensor of the point-spread function. The eigensystem of this tensor determines the optimal relative orientation between the two sources, and reflection symmetries of the point-spread function can further provide a simplified means of identifying the optimal orientation. This geometric structure is coordinate invariant and provides a direct strategy for improving resolution by physically rotating an anisotropic imaging system to align its optimal principal response direction with the source displacement. For a general three-dimensional Gaussian point-spread function, the response tensor is proportional to the inverse spatial covariance, establishing a direct connection between quantum-limited distance precision and the geometry of Gaussian distribution.

quant-pharXiv:2608.04876•Aug 6, 2026•0 citations

Quantum-limited superresolution of two arbitrary incoherent point sources: Beating the resurgence of Rayleigh's curse

Junyan Li, Shengshi Pang

Superresolution has been demonstrated to overcome the limitation of Rayleigh's criterion and achieve significant precision improvement in resolving the separation of two incoherent optical point sources. However, in recent years, it was found that, if the photon numbers of two incoherent optical sources are unknown, the precision of superresolution vanishes when the photon numbers are actually different. In this work, we first analyze in detail the estimation precision of the separation for two incoherent optical sources with the same point-spread functions and show that, when the two photon numbers are different but sufficiently close, the superresolution can still be realized but with different precisions. We find the condition on how close the photon numbers need to be to realize the superresolution and derive the precision of superresolution in different regimes of the photon number difference. We further consider the superresolution for two incoherent optical sources with different point-spread functions and show that the competition between the difference of photon numbers, the difference of point-spread functions, and the separation of source locations determines the precision of superresolution. The results exhibit precision limits distinct from that of two identical point-spread functions with equal photon numbers and extend the realizable regimes of quantum superresolution. Finally, the results are illustrated by Gaussian point-spread functions. Published by the American Physical Society 2024

arXiv:2403.13752•Physical Review A•Oct 17, 2024•2 citations

Quantum Theory of Superresolution for Two Incoherent Optical Point Sources

Mankei Tsang, Ranjith Nair, Xiao-Ming Lu

Rayleigh's criterion for resolving two incoherent point sources has been the most influential measure of optical imaging resolution for over a century.In the context of statistical image processing, violation of the criterion is especially detrimental to the estimation of the separation between the sources, and modern far-field superresolution techniques rely on suppressing the emission of close sources to enhance the localization precision.Using quantum optics, quantum metrology, and statistical analysis, here we show that, even if two close incoherent sources emit simultaneously, measurements with linear optics and photon counting can estimate their separation from the far field almost as precisely as conventional methods do for isolated sources, rendering Rayleigh's criterion irrelevant to the problem.Our results demonstrate that superresolution can be achieved not only for fluorophores but also for stars.

arXiv:1511.00552•Physical Review X•Aug 29, 2016•474 citations

Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution

Jaroslav Řeháček, Z. Hradil, B. Stoklasa +4 more

We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.

arXiv:1709.07705•Physical Review A•Dec 7, 2017•169 citations

Towards Superresolution Surface Metrology: Quantum Estimation of Angular and Axial Separations

Carmine Napoli, Samanta Piano, Richard Leach +2 more

We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.

arXiv:1805.04116•Physical Review Letters•Apr 12, 2019•81 citations

Quantum limit for two-dimensional resolution of two incoherent optical point sources

Shan Zheng Ang, Ranjith Nair, Mankei Tsang

We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the $x$ and $y$ components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.

arXiv:1606.00603•Physical Review A•Jun 29, 2017•96 citations
The Rayleigh criterion has long served as a fundamental limit for the resolution of optical imaging. Recent advances in multiparameter quantum metrology have led to quantum superresolution that can break this limit and achieve nonvanishing precision in estimating the separation between a pair of closely located incoherent point sources. For two-dimensional optical systems, the quantum superresolution has been studied for the Cartesian components of separation between two incoherent point sources. However, the precision limit of estimating the full distance between two point sources remains unknown so far. In this paper, we investigate the estimation precision of the full distance between two incoherent point sources with arbitrary intensities in a two-dimensional imaging system. Through the multiparameter quantum estimation theory, we obtain the ultimate estimation precision for the distance and show that it remains nonzero when the distance approaches zero, which surpasses the Rayleigh criterion. We further show the dependence of the estimation precision on the relative orientation between the two point sources, which leads to a novel scheme that can enhance the precision by aligning the sources along proper directions if the point-spread functions are not circularly symmetric, and the enhancement is determined by the extent to which the point-spread functions deviate from circular symmetry. Finally, the results are illustrated by incoherent sources with Gaussian point-spread functions.
Quantum superresolution reveals that the vanishing of separation sensitivity in conventional imaging below the Rayleigh limit does not necessarily indicate a fundamental loss of information in the optical field. However, the quantum limit for estimating the physical distance between two incoherent point sources in three-dimensional imaging systems and its dependence on the spatial structure of the point-spread function remains largely unknown. In this work, we derive the quantum-limited precision for estimating the full distance between two incoherent point sources with arbitrary intensity imbalance in a three-dimensional spatially invariant imaging system. We show that the distance information remains finite in the sub-Rayleigh regime and is governed by the second-order displacement-response tensor of the point-spread function. The eigensystem of this tensor determines the optimal relative orientation between the two sources, and reflection symmetries of the point-spread function can further provide a simplified means of identifying the optimal orientation. This geometric structure is coordinate invariant and provides a direct strategy for improving resolution by physically rotating an anisotropic imaging system to align its optimal principal response direction with the source displacement. For a general three-dimensional Gaussian point-spread function, the response tensor is proportional to the inverse spatial covariance, establishing a direct connection between quantum-limited distance precision and the geometry of Gaussian distribution.
Superresolution has been demonstrated to overcome the limitation of Rayleigh's criterion and achieve significant precision improvement in resolving the separation of two incoherent optical point sources. However, in recent years, it was found that, if the photon numbers of two incoherent optical sources are unknown, the precision of superresolution vanishes when the photon numbers are actually different. In this work, we first analyze in detail the estimation precision of the separation for two incoherent optical sources with the same point-spread functions and show that, when the two photon numbers are different but sufficiently close, the superresolution can still be realized but with different precisions. We find the condition on how close the photon numbers need to be to realize the superresolution and derive the precision of superresolution in different regimes of the photon number difference. We further consider the superresolution for two incoherent optical sources with different point-spread functions and show that the competition between the difference of photon numbers, the difference of point-spread functions, and the separation of source locations determines the precision of superresolution. The results exhibit precision limits distinct from that of two identical point-spread functions with equal photon numbers and extend the realizable regimes of quantum superresolution. Finally, the results are illustrated by Gaussian point-spread functions. Published by the American Physical Society 2024
Rayleigh's criterion for resolving two incoherent point sources has been the most influential measure of optical imaging resolution for over a century.In the context of statistical image processing, violation of the criterion is especially detrimental to the estimation of the separation between the sources, and modern far-field superresolution techniques rely on suppressing the emission of close sources to enhance the localization precision.Using quantum optics, quantum metrology, and statistical analysis, here we show that, even if two close incoherent sources emit simultaneously, measurements with linear optics and photon counting can estimate their separation from the far field almost as precisely as conventional methods do for isolated sources, rendering Rayleigh's criterion irrelevant to the problem.Our results demonstrate that superresolution can be achieved not only for fluorophores but also for stars.
We establish the multiparameter quantum Cram\'er-Rao bound for simultaneously estimating the centroid, the separation, and the relative intensities of two incoherent optical point sources using a linear imaging system. For equally bright sources, the Cram\'er-Rao bound is independent of their separation, which confirms that the Rayleigh resolution limit is just an artifact of the conventional direct imaging and can be overcome with an adequate strategy. For the general case of unequally bright sources, the amount of information one can gain about the separation falls to zero, but we show that there is always a quadratic improvement in an optimal detection in comparison with the intensity measurements. This advantage can be of utmost importance in realistic scenarios, such as observational astronomy.
We investigate the localization of two incoherent point sources with arbitrary angular and axial separations in the paraxial approximation. By using quantum metrology techniques, we show that a simultaneous estimation of the two separations is achievable by a single quantum measurement, with a precision saturating the ultimate limit stemming from the quantum Cramér-Rao bound. Such a precision is not degraded in the subwavelength regime, thus overcoming the traditional limitations of classical direct imaging derived from Rayleigh's criterion. Our results are qualitatively independent of the point spread function of the imaging system, and quantitatively illustrated in detail for the Gaussian instance. This analysis may have relevant applications in three-dimensional surface measurements.
We obtain the multiple-parameter quantum Cram\'er-Rao bound for estimating the transverse Cartesian components of the centroid and separation of two incoherent optical point sources using an imaging system with finite spatial bandwidth. Under quite general and realistic assumptions on the point-spread function of the imaging system, and for weak source strengths, we show that the Cram\'er-Rao bounds for the xxx and yyy components of the separation are independent of the values of those components, which may be well below the conventional Rayleigh resolution limit. We also propose two linear-optics-based measurement methods that approach the quantum bound for the estimation of the Cartesian components of the separation once the centroid has been located. One of the methods is an interferometric scheme that approaches the quantum bound for sub-Rayleigh separations. The other method using fiber coupling can, in principle, attain the bound regardless of the distance between the two sources.